Stations: 06, System, Port Combinations: Ejector System, Common PV: ø8, Metric Size, Exhaust: 1 [Ejector System, Silencer Common Exhaust (End Plate on Both Sides)], Wiring: D-sub Connector, 25 Pins, Option: B+D, Manifold Assembly, Delivery Condition: Delivered as Individual Parts, not Assembled
Stations: 06, System, Port Combinations: Ejector System, Common PV: ø5/16", Inch Size, Exhaust: 1 [Ejector System, Silencer Common Exhaust (End Plate on Both Sides)], Wiring: N [No Wiring, (No Valve)], Option: None, Manifold Assembly, Delivery Condition: Delivered as Individual Parts, not Assembled
Size: 5 (50), Valve Type: 1 (Normally Closed), Body Material: C (Brass), Seal Material: F (FKM), Port Size: 06 (Thread; 3/4), Thread Type: R (Rc), Rated Voltage: 3 [120 (110) VAC], Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor)
Size: 5 (50), Valve Type: 1 (Normally Closed), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 06 (Thread; 3/4), Thread Type: N (NPT), Rated Voltage: 6 (12 VDC), Electrical Entry: G (Grommet), Oil-free Option: None, Bracket: B (Bracket)
Handle Position: A (Upper), Piping: 1 (IN/OUT: Bottom), Fitting: 06 (IN: Straight Ø4, OUT: Straight Ø4), Accessory: A (Pressure Gauge), Option: None, Unit: ZA [Digital Pressure Switch w/Unit Switching Function (MPa)], Digital Pressure Switch Output Specifications: P (PNP open collector)
Function: 1 (2 Position Single), Body Option: 00 (Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 06 (Sub-plate Plug-in Terminal 3/4, Non Plug-in Standard 3/4)
Body Class: 3 (Orifice Dia. ø8), Valve Type: 0 (N.C.), Applicable Tubing Size: 06 (ø6mm), Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: Standard, Option: 2 (With By-Pass)
Body Class: 2 (Orifice Dia. ø4), Valve Type: 0 (N.C.), Applicable Tubing Size: 06 (6 x 4), Port B (Out) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: Rc 1/8, Pilot Port Position: None (Position 1), Material: FN (Body: PFA; End Plate: PVDF; Diaphragm: PTFE; Seal, Buffer: EPDM)
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: Rc, Port Size: 06 (3/4), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: N (NPT), Port Size: 06 (3/4), Output Specifications: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: N (NPT), Port Size: 06 (3/4), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: S (Brass or BC6, Copper Body & Shading Coil PTFE (FPM)Seal, Class H Coil), Port Size: 06 [3/4 (20A)], Thread: Rc, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Function: 1 (2 Position, Single), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 1 (100 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4)
Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: DO (DIN Terminal w/o Connector), Surge Suppressor: None, Manual Override: B (Locking Slotted Style), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: F (G)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: F (G)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: E (Grommet Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: N (NPT)
Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 1 (100 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: N (NPT)