Positioning time -> 0003h -> 0.03 s Number of bytes -> 02h -> 2 Example 2) When reading the target position (setting: 5000 m) and the positioning time (setting 0.03 s) for Step Data No. 10 of the controller with controller ID: 1 Request to be sent ":010305303CRLF" (are the checksum.)
LEMB / LEMC LEMH / LEMHT Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] 0 48 250 48 250 1 75 500 75 500 2 100 1000 100 1000 3 150 1500 150 1500 4 200 2000 200 2000 5 250 2500 300 2500 6 300 3000 400 3000 7 350 4000 500 4000 8 400 5000 600 5000 9 450 6000 800 6000 10 500 7500 1000 7500 11 600 10 1200 10 12 700 12500 1400 12500 13 800 15000 1600 15000 14 900 17500 1800
1.4 mm Blue, Brown 0.7 mm White, Green, Light green, Purple, Gray, Yellow Insulator Outside diameter 3000 Material Outside diameter Heat resistant PVC 6.2 mm Sheath 9800 Remote controller Infrared rays generating part 7 21 48 14 100 2 AAA batteries to be set 17 Transition wiring cable/IZS41-CF 17.5 17.5 16.4 6.2 B A 1 5 BA 5 1 L (mm) IZF41-CF02 IZF41-CF05 IZF41-CF08 16.4 Part no. 2000 5000
100/100 15 Series KV2 Accessories Plugs KV2P-_ _ L1 A D1 D2 D3 Applicable Tube (Inch) Part Number A* D1 Weight (grams) Bag/Box Quantity D2 D3 L 6.0 8.5 11.5 15.0 20.0 24.0 2.8 4.5 7.0 9.7 12.2 14.7 5/32 1/4 3/8 1/2 5/8 3/4 KV2P-03 KV2P-07 KV2P-11 KV2P-13 KV2P-15 KV2P-19 32.0 35.0 43.0 45.5 47.0 56.0 16.0 18.0 22.0 23.5 20.5 22.6 4.0 6.4 9.5 12.7 15.9 19.1 0.5 1 2 4 7 12 1000/2000 1000/5000
Relation between clamp arm length and maximum clamping force The length of the clamp arm L should be the length given below or less. operating pressure 0.5 MPa 5000 Arm length L Model 4000 Clamping force (N) CKZ3N50 CKZ3T50 CKZ3N63 CKZ3T63 150 mm 63 3000 300 mm 2000 50 1000 0 350 300 250 200 150 100 50 0 Arm length L (mm) Series CKZ3N Allowable load for clamp arm end Refer to the graph on
D E F G H Nominal size Pitch Compression Tension JB40-8-125 JB63-10-150 JB80-16-200 JB100-20-250 JB140-22-250 20, 25 32 40 50, 63 80 8 10 16 20 22 29 35.5 47.5 59 71.5 1.25 1.5 2 2.5 2.5 51 62.5 80.5 101 129 8.5 10 16 21 18 13 15 18 24 38 11 13 20 26 22 31 41 50 59.5 79 6 7.5 9.5 11.5 14 11 14 19 24 30 0.15 0.29 0.56 1.04 2.6 11 13.5 16 20 22 22 27 32 41 46 0.75 1 1.25 2 2.5 1300 3100 5000
Rodless Cylinder With Protective Cover Specifications Bore size (mm) 16 20 25 32 40 50 63 Fluid Air Action Double acting Operating pressure range MY1MW: 0.15 to 0.8 MPa; MY1CW: 0.1 to 0.8 MPa Proof pressure 1.2 MPa 5 to 60C Ambient and fluid temperature Cushion Air cushion MX Lubrication Non-lube JIS Symbol +1.8 0 +2.8 0 1000 or less 1001 to 3000 +1.8 0 +2.8 0 MTS 2700 or less ; 2701 to 5000
Compression Tension -X JB40-8-125 JB63-10-150 JB80-16-200 JB100-20-250 JB140-22-250 20, 25 32 40 50, 63 80 8 10 16 20 22 1.25 1.5 2 2.5 2.5 51 62.5 80.5 101 129 29 35.5 47.5 59 71.5 13 15 18 24 38 0.15 0.29 0.56 1.04 2.6 8.5 10 16 21 18 11 13 20 26 22 31 41 50 59.5 79 6 7.5 9.5 11.5 14 11 14 19 24 30 11 13.5 16 20 22 22 27 32 41 46 0.75 1 1.25 2 2.5 6000 11000 18000 28000 54000 1300 3100 5000
(Nashville) 5000 Linbar Drive, Suite 297 Nashville, TN 37211 Tel: (615) 331-0020 FAX: (615) 331-9950 SMC Pneumatics Inc. (Dallas) 12801 N. Stemmons Frutry, Ste.815 Dallas, TX 75234 rel: (972\ 406-0082 FAX: (972) 406-9904 SMC Pneumatics lnc. (S.F.) 85 Nicholson Lane San Jose, CA 95134 Tel: (408) 943-9600 FAX: (408) 943-9111 SMC Pneumatics Inc.
(Nashville) 5000 Linbar Drive, Suite 297 Nashville, TN 37211 Tel: (615) 331-0020 FAX: (615) 331-9950 SMC Pneumatics Inc. (Dallas) 12801 N. Stemmons Frutry, Ste.815 Dallas, TX 75234 rel: (972\ 406-0082 FAX: (972) 406-9904 SMC Pneumatics lnc. (S.F.) 85 Nicholson Lane San Jose, CA 95134 Tel: (408) 943-9600 FAX: (408) 943-9111 SMC Pneumatics Inc.
SV1000/2000/3000/4000 SY3000/5000 VQC1000/2000/4000 S0700 -31No.EX##-OMO0019 Dimensions 1. SI unit for SV series valves (EX500-S001) 2.
SL5502 SL5510 SL5506 100 mm Hg absolute to 30 psig (-88 kPa to 0.2 MPa) 1 to 30 psig (0.007 to 0.2 MPa) 2 to 100 psig (0.014 to 0.7 MPa) 1 to 60 psig (0.007 to 0.4 MPa) Operating Parameters Delivery pressure Select compatible materials of construction for the gas Gas Source pressure Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Vacuum to 3500 psig (24.1 MPa) 5000
(Nashville) 5000 Linbar Drive, Suite 297 Nashville, TN 37211 Tel: (615) 331-0020 FAX: (615) 331-9950 SMC Pneumatics Inc. (Boston) Zero Centennial Drive Peabody, MA 01960 Tel: (978) 326-3600 Fax: (978) 326-3700 SMC Pneumatics Inc. (S.F.) 85 Nicholson Lane San Jose, CA 95134 Tel: (408) 943-9600 FAX: (408) 943-9111 SMC Pneumatics Inc. (Dallas) 12801 N.
0.2 0.1 0.1 0.1 0 1000 Flow rate (l/min (ANR)) 0 3000 4000 1000 2000 0 150 125 100 75 50 25 0 0 0 500 1500 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) AW20(K) Rc 1/4 AW40(K) Rc 1/2 AW60(K) Rc 1 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 600 800 400 200 Flow rate (l/min (ANR)) 0 2000 00 5000
holding force 20 20mm Refer to the magnet holding force table below. 25 25mm 32 32mm 40 40mm 50 50mm 63 63mm Standard Stroke Table Bore size (mm) Standard stroke (mm) Maximum Note) available stroke (mm) 300 50, 100, 150, 200 6 500 50, 100, 150, 200, 250, 300 10 50, 100, 150, 200, 250, 300, 350 400, 450, 500 15 1000 20 2000 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25 4000 32 5000
Bore size (mm) Operating direction Operating pressure (MPa) (3) Bore size (mm) Foot (1) Flange Double clevis 0.3 0.5 0.7 71 94 113 147 181 241 317 377 495 589 841 935 1360 1510 2140 2360 118 157 189 245 302 402 528 628 825 982 1400 1560 2270 2510 3570 3930 165 220 264 344 422 563 739 880 1150 1370 1960 2180 3170 3520 5000 5500 IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT 20 25
Unit: g Weight Auto Switch Internal Circuit Auto switch model D-P3DW/L/Z 0.5 20 D-P3DW/L/Z 3 102 Lead wire length (m) 5 168 Switch main circuit OUT () Brown Dimensions Unit: mm OUT ( ) Blue Body 4.8 Indicator light 6 Indicator light/Display method 2.8 mounting hole 3 29 500 (3000, 5000) ON Operating range OFF 3.2 11 1 Display Red Green Red 10.5 Most sensitive position Proper operating range
50,100 50,100,150 Max. work load [kg] *1 *3 2 8 12 Horizontal Vertical 1.5 3 6 6 12 10 20 Pushing force 35% to 70%[N] *2 *3 18 to 36 37 to 74 69 to 138 91 to 182 174 to 348 109 to 218 210 to 420 Max. speed[mm/s] *1 *3 400 200 100 400 200 400 200 Actuator specifications Pushing speed[mm/s] 20 to 30 10 to 30 5 to 30 20 to 30 10 to 30 20 to 30 10 to 30 Max. acceleration/deceleration[mm/s2] 5000
Specifications: Same as standard type Stroke Range Model Bore size (mm) Standard stroke (mm) Long stroke (mm) Model Bore size (mm) Standard stroke (mm) Long stroke (mm) MY1B-Z 2001 to 5000 601 to 1500 100 to 2000 50 to 600 25, 32, 40 225, 250, 275, 300 (CXWM16 to 25) 225, 250 (CXWM32) 225, 250, 275 (CXWL16 to 25) 225 (CXWL32) MY1H-Z CXWM 25, 32, 40 2001 to 5000 (Up to 3000 for 10, 16) 10,
IN 841 1400 1960 63 OUT 935 1560 2180 IN 1360 2270 3170 80 OUT 1510 2510 3520 IN 2140 3570 5000 100 OUT 2360 3930 5500 Unit: J Allowable Kinetic Energy 4.54 100 Bore size(mm) 12 0.075 16 0.11 20 0.18 25 0.29 32 0.52 40 0.91 50 1.54 63 2.71 80 Kinetic energy 0.043 Auto Switch Mounting Bracket Part No. Applicable switch Reed switch Solid state switch Bore size (mm) Part No.