Note) Metric sizes 04 06 08 10 12 4 6 8 10 12 Elbow Control type 0 1 Meter-out Meter-in Note) For applicable tubing O.D. selection, refer to the Model on page 711.
(mm) GC F D BB A 10 16 15 15 15 18.3 12 18.3 14 20 4 5 8 8 5 5 11 11 CA GA BA CB GB 5 5 NN Z 82 83 54 55 M4 x 0.7 M5 x 0.8 S NB NDh8 20.5 20.5 9.5 9.5 10-0.022 0 MM Bore size H 28 28 17 20 NA M10 x 1.0 12-0.027 0 M12 x 1.0 With air cushion With air cushion type is not available for 21-/22-CJ2.
(Values at the initial period) Dustproof Solenoid Specifications Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 12, 24 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz Electrical entry AC DC Rated voltage (V) Base mounted Allowable voltage fluctuation Inrush Holding Apparent power (AC) Diode (12 VDC or less: Varistor) Varistor 4.3 W (Standard), 2.3 W (Low wattage
XSA1 4.5 6 XSA2 7 8 XSA3 10.5 11.5 Reverse pressure potential 0.5 MPa(G)*1 Weight New New 18% *1 XSA1-12 (Refer to the Specifications on page 3.) 0.5 kg 0.41 kg lighter *1 Rated voltage *1 XSA2-2 32 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC 24 V, 12 V Applications Photovoltaic cell manufacturing Semiconductor manufacturing LCD manufacturing New New Female thread type (Rc,
(Aluminum: 6.5 g, Stainless steel: 17.6 g) ZNC30 to 80: The weight value is for the basic type without a plug. *6 For pressure sensor details, refer to the PSE540 series in the Web Catalog and the Operation Manual. 6 ZNC Series Lifting Force ZNC20m ZNC30m ZNC40m 12 16 6 14 10 5 12 8 Lifting force [N] Lifting force [N] Lifting force [N] 4 10 6 8 3 6 4 2 4 2 1 2 0 0 0 0 0.6 0.5 0.4 0.3 0.2
EX600-ZT1 (6)Assembled type connector PCA-1446553: For EtherNet/IPTM communication, M12 (4 pin) Plug, D code PCA-1578078: For power supply, 7/8 inch, Plug, Cable O.D. 12 to 14 mm PCA-1578081: For power supply, 7/8 inch, Socket, Cable O.D. 12 to 14 mm (7)Power supply cable PCA-1558810: Cable with 7/8 inch connector, Socket, Straight 2 m PCA-1558823: Cable with 7/8 inch connector, Socket, Straight
Check if there is a noise source An over current error (Er1 and 2) is indicated. (2)Check if the power supply voltage is in the range of 12 to 24 VDC. (2)Supply power voltage of 12 System error to 24 VDC.
KPa, kgf/cm2, bar, psi Temp. oC, oF 0 to 2100 L/min 0 to 1050 L/min Instantaneous flow 12 (Displays 0 when the value is below 20 L/min.) (Displays 0 when the value is below 10 L/min.)
MODE FUNC 5.4 Operation of Controller 5-12 A_HEC-OM-J004-4 Chapter 5 Operation [Tips] PV Indicator for unavailable change If a change in a parameter in the control mode (refer to page 5-12, 5.4.9 Details of Control Setting Mode) is attempted when 2 (RUN/READY setting) is selected, the indicator as shown on the left appears to show that the change is not available.
Additionally, note that the 12 VDC relay does not apply to the auto switch. -12- 11. Pay attention to leakage current. <2-wire type> Current (leakage current) flows to the load to operate the internal circuit even when in the OFF state.
ID 0 1 2 1 063 1ABS() 3 1 ) 2INC() 4 H 2 065500 mm/s 5 L 6 3 7 2 4 2147483647 0.01mm 8 1 9 0 ID1 10 H 2 065500 mm/s2 11 L 12 H 2 065500 mm/s2 13 L 14 1 030 10% 15 1 030 10% 16 1 0255 mm/s 17 1 030 10% 18 H 2 065500 0.01mm 19 L ID2 2039 ID1 ID3 4059 ID1 ID4 6079 ID1 ID5 8099 ID1 ID6 100119 ID1 ID7 120139 ID1 ID8 140159 ID1 ) 0 12 36 - / Bit No.
Data writing mode.38 12. Memory map .39 12. 1 Memory assignment.39 12. 2 Controller IF status flagIN Data.43 12. 3 Gateway unit status flagIN Data.43 12. 4 Gateway unit control flagOUT Data.45 13. Precautions for controlling the controller (LEC).46 13. 1. Communication delay between the gateway unit unit and the controller(LEC) 46 13. 2.
Tighten others with 0.60.05Nm. -27- 12. Domensions 12-1.
Specification for Option S 12 1 Safety instructions . 12 1 12 2 Specifications . 12 1 12 3 Electric circuit . 12 1 Chapter 13 Specification for Option T 13 1 Safety instructions . 13 1 13 2 Specifications . 13 1 13 3 Remote operation . 13 1 13 4 How to connect the power and signal cable . 13 2 13 5 How to re-start the operation . 13 2 13 6 Electric circuit . 13 3 Chapter 14 Specification
Regarding mounting, refer to Section 3.1.2. 79 No.EX-OMW0011-B 12. Dimensions 12.1. The Modules Manifold Fig. 12-1 Dimensions of the Modules manifold NOTE Fig. 12-1 shows when the EX245-EA2-1 is used. The following table shows the length of the Modules manifold. For the valve manifold side, refer to the instruction manual for the appropriate valve series.
Incorrect operation of the internal data of the Pressure switch (Er0, Er4, Er6, Er7, Er8, Er9) System error (Er0, Er4, Er6, Er7, Er8 or Er9) is displayed. (2) Check that the power supply voltage is within the range 12 to 24 VDC 10%. (2) Supply a correct voltage of 12 to 24 VDC 10%.
-wire (PNP) 12 V 2-wire Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Grommet 5 V, 12 V 24 V Diagnostic indication (2-color indication) 2-wire 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V, 12 V Lead wire length symbols: 0.5 mNil (Example) E76A 3 mL (Example) E76AL 5 mZ (Example) M5NTZ Solid state switches marked with are produced upon receipt of order.
-wire (PNP) 12 V 2-wire Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Grommet 5 V, 12 V 24 V Diagnostic indication (2-color indication) 2-wire 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V, 12 V Lead wire length symbols: 0.5 mNil (Example) E76A 3 mL (Example) E76AL 5 mZ (Example) M5NTZ Solid state switches marked with are produced upon receipt of order.
MSUB 1=m 12 a 2 1=m 5 2r 2 eThin rectangle board (Parallelogram) iDisc Position of rotation axis: Disc centered about axis of rotation.
Side mounting Body tapped Maximum tightening Thread depth: Max. thread depth: Model Bolt L1(mm) L2(mm) torque MXQ6 M40.7 2.1 5 8 MXQ8 M40.7 2.1 8 11 MXQ12 M50.8 4.4 11 15 MXQ16 M61 7.4 14 19 MXQ20 M61 7.4 9 MXQ25 M81.25 18 12 MXQ6A M40.7 2.1 8 11 MXQ8A M40.7 2.1 8 11 MXQ12A M50.8 4.4 8 12 MXQ16A M61 7.4 12 17 MXQ20A M61 7.4 9 MXQ25A M81.25 18 12 MXQ6B M40.7 2.1 5 8 MXQ8B M50.8 4.4 4 9 MXQ12B