SHOCK ABSORBER, Shock absorber modelApplicable slide tableMax. absorbed energy (J)Stroke absorption (mm)Collision speed (mm/s)Max. operating frequency (cycle/min)Max. allowable thrust (N)Ambient temperature range (C)Spring force (N)Weight (g)?MXQR6RJ1410MXQR203.71050 to 50045814?10 to 60C (No freezing)6.414.665
SHOCK ABSORBER, Shock absorber modelApplicable slide tableMax. absorbed energy (J)Stroke absorption (mm)Collision speed (mm/s)Max. operating frequency (cycle/min)Max. allowable thrust (N)Ambient temperature range (C)Spring force (N)Weight (g)?MXQR6RJ1006MXQR161.5650 to 50070422?10 to 60C (No freezing)5.48.023
SHOCK ABSORBER, Shock absorber modelApplicable slide tableMax. absorbed energy (J)Stroke absorption (mm)Collision speed (mm/s)Max. operating frequency (cycle/min)Max. allowable thrust (N)Ambient temperature range (C)Spring force (N)Weight (g)?MXQR6RJ1006MXQR161.5650 to 50070422?10 to 60C (No freezing)5.48.023
SHOCK ABSORBER (PT), SOFT TYPE, Applicable cylinderShock absorber modelMax. absorbed energy (J)Stroke absorption (mm)Collision speed (m/s)Max. operating frequency (cycle/min)Max. allowable thrust lbf (N)Ambient temperatureCY1S;20RJ1007L370.05 to 17094.9(422)14 to 140 F ( 10 to 60nC) (No freezing)
SHOCK ABSORBER, Shock absorber modelApplicable slide tableMax. absorbed energy (J)Stroke absorption (mm)Collision speed (mm/s)Max. operating frequency (cycle/min)Max. allowable thrust (N)Ambient temperature range (C)Spring force (N)Weight (g)?MXQR6RJ0805MXQR80.5550 to 50080245?10 to 60C (No freezing)ExtendedRetracted15
SHOCK ABSORBER, Shock absorber modelApplicable slide tableMax. absorbed energy (J)Stroke absorption (mm)Collision speed (mm/s)Max. operating frequency (cycle/min)Max. allowable thrust (N)Ambient temperature range (C)Spring force (N)Weight (g)?MXQR6RJ1006MXQR161.5650 to 50070422?10 to 60C (No freezing)5.48.023
Part Number Description: REPLACEMENT COVER (5K4-10) Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 115 Family Description: AR REGULATOR Class Code: 21 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.002, Operating
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.002, Operating
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.002, Operating
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.002, Operating
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.002, Operating
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.002, Operating
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.002, Operating
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Tube Nominal Diameter: 12, Valves: Not Provided, Allowable Kinetic Energy(J): 0.006
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Tube Nominal Diameter: 12, Valves: Not Provided, Allowable Kinetic Energy(J): 0.006
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Tube Nominal Diameter: 12, Valves: Not Provided, Allowable Kinetic Energy(J): 0.006
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Tube Nominal Diameter: 12, Valves: Not Provided, Allowable Kinetic Energy(J): 0.006
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Tube Nominal Diameter: 12, Valves: Not Provided, Allowable Kinetic Energy(J): 0.006
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Tube Nominal Diameter: 12, Valves: Not Provided, Allowable Kinetic Energy(J): 0.006