L Speed: V [mm/s] a1 a2 T1 = V/a1 = 300/3000 = 0.1 [s], T3 = V/a2 = 300/3000 = 0.1 [s] Time [s] T = T1 + T2 + T3 + T4 [s] L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be obtained by the following equation.

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: ø4 One-touch Fitting, Straight Type, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: ø6 One-touch Fitting, Straight Type, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: ø1/4" One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C4H (ø4 One-touch Fitting, Straight Type)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6H (ø6 One-touch Fitting, Straight Type)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N7L (ø1/4" One-touch Fitting, Elbow Type)

Solid State Switch D-M9B(V), D-M9N(V), D-M9P(V) Solid State Switch D-M9B(V), D-M9N(V), D-M9P(V) Electrical entry (Fetching direction) 2-color Indication Solid State Switch D-F9BW(V), D-F9NW(V), D-F9PW(V) 2-color Indication Solid State Switch D-F9BW(V), D-F9NW(V), D-F9PW(V) (mm) Type Model Features Grommet (In-line) D-A90 Stroke (mm) 20 41 29 47 35 Without indicator light Stroke (mm) 10

Model no. of NPT thread is AN101-N01 and AN110-N01. It can operate in temperatures between 10 to 150C if there is no risk of the moisture in the air freezing.

Time [s] LEC SS-T T1 T2 T3 T4 T1 = V/a1 [s] T3 = V/a2 [s] LEC Y T2: Constant speed time can be found from the following equation.

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

MXP16 Solid state switch D-F9B(V), D-F9N(V), D-F9P(V) Tightening torque Set screw (Attached to auto switch) mm Tightening torque should around 0.44 to 0.89 in lb (0.05 to 0.1Nm). When you begin to feel that the screw is being tightened, turn it an additional 90.

AS121FM-U10/32-01 AS121FM-U10/32-03 AS121FM-U10/32-05 AS121FM-U10/32-07 AS221FM-N01-01 AS221FM-N01-03 AS221FM-N01-05 AS221FM-N01-07 AS221FM-N01-09 AS221FM-N02-03 AS221FM-N02-05 AS221FM-N02-07 AS221FM-N02-09 AS221FM-N02-11 1/8" 5/32" 3/16" 1/4" 1/8" 5/32" 3/16" 1/4" 5/16" 5/32" 3/16" 1/4" 5/16" 3/8" 8.4 9.3 11.4 12 12.7 22.1 12.3 17.3 7 9.6 30.1 28.8 25.1 8 33.8 10-32 UNF 16.5 13.5 26.1 23.1

-01 12.7 20.4 27.5 4 9.3 1/8" 16 20.4 27.5 17 9.3 12.7 AS221FG-01-06 AS221FG-N01-03 13.5 20.4 13.4 27.5 6 11.6 5/32" 14.2 13.4 27.1 30.2 35.2 12 32.1 NPT 1/8 R 1/8 17 AS221FG-01-08 AS221FG-N01-05 23.1 12.7 30.2 19 18.5 35.2 25.3 32.1 30.2 32.4 8 15.2 3/16" 11.4 27.1 16.5 14.2 AS221FG-01-10 AS221FG-N01-07 23.9 31 21 21 32.1 14.1 39.2 10 18.5 1/4" 13.2 17 19 AS221FG-02-04 AS221FG-N01-09 14.1

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: w/o Lead Wire, Option 2: Bracket B, Horizontal Mounting, Option 3: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: w/o Lead Wire, Option 2: Bracket B, Horizontal Mounting, Option 3: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: w/o Lead Wire, Option 2: Bracket B, Horizontal Mounting, Option 3: -