SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20A-Y-P-M5-JB"

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: ø1/4" One-touch Fitting, Straight Type, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: ø1/4" One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N7H (ø1/4" One-touch Fitting, Straight Type)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N7L (ø1/4" One-touch Fitting, Elbow Type)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6H (ø6 One-touch Fitting, Straight Type)

Dedicated Controller/LC1 P.73 Controller setup software P.80 Dedicated teaching box P.82 Options P.85 Dedicated Regenerative Absorption Unit/LC7R P.86 Non-standard Motor Compatible Drivers P.89 73 2 Series LC1 Controller Single Axis Type Built-in AC Servo Driver Series LTF: Standard Motor Compatible How to Order 2V LC1 F 1 H 1 L 3 Number of axes Mounting bracket 1 3 5 1 axis M3

x 0.8 Rc 1/8 Rc 1/8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M3 x 0.5 Except lock unit, 0.12 MPa for 12 and 16; 0.10 MPa for 20 to 40 respectively.

-RA Both ends tapped (CQMA) (mm) Without auto switch With auto switch Stroke range (mm) Bore size (mm) P P EA EB EC B F Q A B F Q A TN TF NN NN TN TF 5 5.5 11.5 M5 x 0.8 M5 x 0.8 40 23 32 10 to 50 50 33 7.5 10.5 45 43 34.4 Rc1/8 NPT1/8 NPT1/8 G1/8 7.5 10.5 G1/8 Rc1/8 NPT1/8 NPT1/8 75, 100 50 33 5 to 50 46.5 29.5 40 Rc1/8 NPT1/8 NPT1/8 G1/8 8 11 G1/8 56.5 39.5 8 11 52 50 41.4 Rc1/8 NPT1

Normal operation Value clear Initial setting P.14 Adjust the zero point of atmospheric pressure. Detects and displays pressure and operates switch. Set "Output mode", "Response time" and "Auto/ Manual mode." Auto preset P.14 P.16 The pressure set point is calibrated automatically at the time of adsorption or primary pressure confirmation.

Power consumption P: 20 [kW] Q = P = 20 [kW] Cooling capacity = Considering a safety factor of 20%, 20 [kW] x 1.2 = V: Power supply voltage P 24 [kW] Power consumption e Derive the heat generation amount from the output. Output (shaft power, etc.) W: 13 [kW] w Derive the heat generation amount from the power supply output.

Single acting nomally open: External holding force, Single acting nomally closed: Internal holding force Refer to "Effective Holding Force" for the holding force at each holding position on p.2.4-7 to 2.4-11. Order Made P.2.4-17 2.4-5 Series MHK2 Construction Double acting Single acting @0 !8 !7 e w o Fingers open Normally open !9 t y !5 i u !6 q r !0 !1 !

Incremental type 14.5 mT 10.8 to 13.2 VDC (Ripple 1% or less) 40 mA 0.1 mm/pulse 0.2 mm Note) (at 20C) NPN open collector (35 VDC, 80 mA) A/B phase difference output 50 M or more (500 VDC measured via megohmmeter) (between case and 12E) 33.3 Hz, 2 hours at X, Y and 4 hours at Z JIS D 1601 as standard 30 G, 3 times at X, Y, Z IP50 (IEC standard) Extension cable (Option) 5 m, 10 m, 15 m, 20

RB RZQ Mounting Bolt J C CR D 110 135 160 120 145 170 130 155 180 135 160 185 CH Model RZQB32-25RZQB32-50RZQB32-75RZQB40-25RZQB40-50RZQB40-75RZQB50-25RZQB50-50RZQB50-75RZQB63-25RZQB63-50RZQB63-75Mounting bolt M5 x 110l M5 x 135l M5 x 160l M5 x 120l M5 x 145l M5 x 170l M6 x 130l M6 x 155l M6 x 180l M8 x 135l M8 x 160l M8 x 185l D9.5 8 -X 10 8.5 20Data 16.5 11.5 3 17.5 12.5 3.5 10-10-5 6

Q H 05 1 3 5 ZM JIS Symbol Air supply port Exhaust port Vacuum port Port size connection Nozzle diameter 05 07 0.5 mm 0.7 mm 3 5 M5 x 0.8 M3 x 0.5 Specifications Ejector System Circuit 10 1.0 mm 13 1.3 mm Applicable nozzle size (mm) Supply valve P Q Supply valve and release valve 0.5, 0.7, 1.0, 1.3 Air operated valve H M 0.35 MPa 0.5 MPa Supply pressure Components Port size M3 x 0.5 M5 x

Port size Port size Rc, NPT, TSJ, UOJ Female thread 1/4 M5 02 M5 Symbol Connection Bracket is included as a standard.

P: PTFE F: FKM For VCS30 OR-2380-130P P: PTFE F: FKM For VCS40 OR-2600-180P P: PTFE F: FKM Manifold For VCS20 OR-1400-178P P: PTFE F: FKM OR-2670-178P P: PTFE F: FKM For VCS30, 40 OR-1717-178P When the loosened clip is pulled out in direction using pinchers, etc., the coil can be removed and replaced in direction .

RZQ mounting bolt C CR D 110 135 160 120 145 170 130 155 180 135 160 185 CH Model RZQB32-25RZQB32-50RZQB32-75RZQB40-25RZQB40-50RZQB40-75RZQB50-25RZQB50-50RZQB50-75RZQB63-25RZQB63-50RZQB63-75Mounting bolt M5 x 110l M5 x 135l M5 x 160l M5 x 120l M5 x 145l M5 x 170l M6 x 130l M6 x 155l M6 x 180l M8 x 135l M8 x 160l M8 x 185l 9.5 8 10 8.5 16.5 11.5 3 17.5 12.5 3.5 4 Series RZQ Model Selection