Inch size Metric size 3.2 23 04 06 08 10 12 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 With One-touch fittings Use 1/8" tube. 2 Speed Controller with One-touch Fittings Panel Mount Type, In-line Type Needle Valve/Flow Characteristics AS1001F AS2001F AS2051F Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (/min (ANR)) Flow rate
VACUUM GENERATOR, VACUUM EJECTOR, M18, 111 lb
/Cap (Resin part only) RBC C 08 Applicable model 08 10 14 20 27 RBC2015 RBC2725 RBC0805, 0806 RBC1006, 1007 RBC1411, 1412 Cap Cap cannot be mounted for basic type. Please place an order with cap type from the beginning.
Body size Metric size Inch size 3 4 5 6 1/8 1/4 3/8 1/2 07 09 11 13 06 08 10 12 6mm 8mm 10mm 12mm 1/4 5/16 3/8 1/2 Thread size Universal type 01 02 03 04 1/8 1/4 3/8 1/2 With One-touch fitting Uni-fit thread form Dimensions Models TUBE O.D. d L3 Applicable tubing O.D.
AS421F-04 AS431F-04 63, 80, 100 R 1/2 Elbow type AS121F-U10/32 AS131F-U10/32 6, 10, 16, 20 10-32 UNF AS221F-N01 AS231F-N01 20, 25, 32 NPT 1/8 AS221F-N02 AS231F-N02 20, 25, 32, 40 NPT 1/4 AS AS321F-N02 AS331F-N02 40, 50, 63 NPT 1/4 AS321F-N03 AS331F-N03 40, 50, 63 NPT 3/8 ASP AS421F-N04 AS431F-N04 63, 80, 100 NPT 1/2 ASN Note 1) Elbow type only Note 2) Meter-out and meter-in types can be
Metric sizes Type 04 06 08 10 12 4 6 8 10 12 2 Elbow Control type 0 1 Meter-out Meter-in Port size M5 01 02 03 04 M5 x 0.8 1/8 1/4 3/8 1/2 With One-touch fitting Clean specifications Metal parts material Q G Brass (electoless nickel plated) Stainless steel 304 Needle Valve/Flow Characteristics AS121FP-M5 AS221FP-01 AS221FP-02 08,10 06,08 06 04 04 AS321FP-03 AS421FP-04 12 10 10,12 08 06 15
Be sure to satisfy the following preconditions.
Please be sure to fill in the blank referring to back page 10.
Be sure to satisfy the following preconditions.
Set range can be effectively used by connections below.
(When setting 3 step, select each set value to be displayed by pressing the DOWN button.) When output operation mode is changed after selecting the 2 value display, the selected display items will not be applicable and [-] will be displayed.
If the security code entered is incorrect, [FAL] will be displayed on the main screen, and the security code must be entered again.
VCR, Swagelok compatible fittings can be selected.
Setting of step data and test drive can be performed on the same page. Can be used to jog and move at a constant rate. Detailed setting Step data can be set in detail. Signals and terminal status can be monitored. Parameters can be set.
For a protection rating of IP65 to be ensured, all covering caps must be screwed down correctly after wiring and setting have been performed.
held with a vice, the display might be damaged. (3) If a tool comes into contact with the boss, it might be broken.
Never mount a product in a location that will be used as a foothold. The product may be damaged if excessive force is applied by stepping or climbing onto it. Do not apply excessive rotational force to the monitor. The monitor with integrated display can be rotated. It can be positioned at 45 and 90 intervals, clockwise and anti-clockwise.
Never mount a product in a location that will be used as a foothold. The product may be damaged if excessive force is applied by stepping or climbing onto it. Do not apply excessive rotational force to the monitor. The monitor with integrated display can be rotated. It can be positioned at 45 and 90 intervals, clockwise and anti-clockwise.
Fig. 8 For side mounting, the mounting dimensions of fork lever-type fitting M can be adjusted to be interchangeable with IP610. For back mounting, the mounting dimensions of fork lever-type fitting S can be adjusted to be interchangeable with IP610. Body cover 2 types of body cover unit can be selected. These can be ordered for replacement. Cover with window to check LCD is optional.
Select the folder in which the step data is to be saved and save the data. Waveform data file (extension: gpf2) will be prepared. If the waveform condition needs to be checked, it can be displayed on the graph window. Click the Save Image button. Select the folder in which the step data is to be saved and save the data. An Image file (extension: jpg) will be prepared.