SMC Corporation of America
Elite Part Number Search
Search Results "VV5FS3-10-101-03"

Model Sensor type Switch Set pressure range Hysteresis Repeatability Diaphragm Solid state Electronic circuit Solid state Reed 27 to 80 kPa 0 to 101 kPa Max. 15 kPa Max. 20 kPa 3% full span or less (Fixed) 1 to 10% of the set pressure (Changeable) 1 to 10% of the set pressure (Changeable) 1% full span or less 3% full span or less 12 to 24 VDC (Ripple 10% or less ) 10% or less 5%F.S.

Unit 1 Disable Does not generate an error. -10..10 V -5..5 V -10..10 V Selects the analogue input range. (AXB: Cannot select -10..10 V/-5..5 V/ -20..20 mA) -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary. Sign & Magnitude Signed binary.

Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 2 Analogue input range Sets the analogue input device range. Selects the analogue input range. -10..10 V Channel 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.

48 48 (63) 0 (10) 40 D-M9, D-M9V 10 (17) 0 0 54 59 (66) 48 58 (65) 5 (12) D-F9W, D-F9WV 10 (17) 0 0 54 59 (66) 48 58 (65) 5 (12) ( ): Denotes the values of D-A9V, D-M9V and D-F9WV.

End Plate EX600-ED2-l EX600-ED3-l Power connector Model specification M12 (5-pin) plug 7/8 inch (5-pin) plug 24 VDC 10%, Class 2, 2 A 24 VDC 10%, 8 A Power supply (for Control/Input) Power supply (for Output) 24 VDC +10/5%, Class 2, 2 A 24 VDC +10/5%, 8 A Enclosure IP67 (Manifold assembly) Standards CE marking, UL (CSA), RoHS recognition Weight 0.4 lbs (170 g) 0.4 lbs (175 g) EX600-ED3-l

DS STROKE Bore E B1 B2 B3 TG1 T L1 L3 I1 I2 FL H d1 d2 d3 CN XD 32 45 14 34 3.3 32.5 3 11.5 41 5 5.5 22 10 30 10.5 6.6 10 142 40 55 16 40 4.3 38 4 12 48 5 5.5 25 10 35 11 6.6 12 160 50 65 21 45 4.3 46.5 4 14 54 5 6.5 27 10 40 15 9 16 170 63 75 21 51 4.3 56.5 4 14 60 5 6.5 32 12 45 15 9 16 190 80 95 25 65 4.3 72 4 16 75 5 10 36 16 45 18 11 20 210 100 115 25 75 6.3 89 4 16 85 5 10 41 16 55

Product number Suitable screws Tightening torque Thread depth PF3A703H Equivalent to M4 1.5 Nm 10 7 PF3A706H Equivalent to M5 3 Nm 10 8 PF3A712H Equivalent to M6 5.2 Nm 10 9 Prepared by the user.

12 16 0.1 5 10 20 30 40 50 100 200 0.01 5 10 20 30 MXW Overhang L (mm) Overhang L (mm) Maximum Speed: Up to 400 (mm/s) Graph (5) Graph (2) Maximum Speed: Up to 300 (mm/s) MXJ 0.3 50 40 30 20 MXP 0.2 10 MXY 0.1 2 3 4 5 Mass W (kg) Mass W (kg) 40 32 MTS 0.04 0.05 1 0.03 0.5 0.4 0.3 0.2 25 20 8 0.02 16 12 0.01 0.1 5 10 20 30 5 10 20 30 40 50 100 200 Overhang L (mm) Overhang L (mm) Graph (3)

V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PFMC7501 5 L/min 500 L/min PFMC7102 10 L/min 1000 L/min PFMC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.

V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PF2MC7501 5 L/min 500 L/min PF2MC7102 10 L/min 1000 L/min PF2MC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.

10 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [] Circulating fluid temperature [] 60Hz 50Hz Fig. 8-3: Cooling Capacity 8.5 Pump Capacity 0.6 60 Usable flow rate range 0.5 50 Circulating fluid outlet (60Hz) Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 0.2 20 Circulating fluid outlet (50Hz) 0.1 10 Circulating fluid return 0.0 0 0 10 20 30 40 50 60 70 80

: 2 to 10 stations U side: 2 to 10 stations Nil Standard length (Specify a longer rail than the standard length.)

24 VDC +10%/-10% Under-voltage detection approx. 18 VDC PWR(V) Operating voltage 24 VDC +10%/-5% Galvanic isolation Yes (between PWR and PWR(V)) Fieldbus Bus protocol PROFINET I/O Version PROFINET Specification Version 2.3 Conformance Class C Yes (Only for IRT switch function) FSU (Fast Start Up) Yes MRP (Media Redundancy Protocol) Yes MRPD (Media Redundancy for Planned Duplication) Yes

ASCII code 5 characters Refer to 5.12.11 Communication example. | 0062h 10 decimal number 0 to 4294967295 16 hexadecimal number 0h to Fh 4 bytes 0063h upper level 0064h lower level 0064h 0063h Control board Program No. 10 decimal number 0 to 65535 16 hexadecimal number 0h to Fh 0065h Control board R Program version 10 decimal number 0 to 4294967295 16 hexadecimal number 0h to Fh 4 bytes 0063h

: 2 to 10 stations U side: 2 to 10 stations Nil Standard length (Specify a longer rail than the standard length.)

Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 5 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low tank fluid level 1 CH1 abnormal high circulating fluid temp. 2 Reservation

Port) (42.9 ) (20.0) (15) (5) (7.5) 5.0 n-M5x0.8 P=10 15.0 *Dimensions 9 122 171 191 225 235.5 n: Stations(Max.18 stations) Equation : L1=10n+32 L2=10n+43 n L 2 52 101 121 150 160.5 3 62 111 131 162.5 173 4 72 121 141 175 185.5 5 82 131 151 175 185.5 6 92 141 161 187.5 198 7 102 151 171 200 210.5 8 112 161 181 212.5 223 10 132 181 201 225 235.5 13 162 211 231 262.5 273 14 172 221 241 275

3.10.1 LRC(ASCII) .3-10 3.10.2 CRC(RTU) .3-10 3.11 Explanation of function codes . 3-12 3.11.1 Function code04 Reading multiple registers .3-12 3.11.2 Function code06 Writing registers .3-13 3.11.3 Function code16 Writing multiple registers .3-14 HRR Series HRX-OM-W004 Contents 3.11.4 Function code23 Reading/writing multiple registers . 3-15 3.12 Negative response . 3-16 3.13 Register Map