SYA5000 3 position closed center 00 3 1 4 02 With sub-plate 3 8 With sub-plate 3 position exhaust center 03 4 3 position pressure center 5 5-2-3 2 Series SYA3000/5000/7000 Specifications Fluid Operating pressure range MPa Air 0.15 to 0.7 0.1 to 0.7 0.2 to 0.7 (0.7 x P + 0.1) to 0.7P: Operating pressure range 0.1 to 0.7 0.2 to 0.7 Max. 60 Non-locking push type Not required Unrestricted 150/30
H A 30 ZPNA-M22 34.6 Bolts Dimensions (mm) A 11 d M3 x 0.5 12 7 M4 x 0.7 B 5.5 L 8 8 10 15 8.5 M5 x 0.8 13-11-82
Type S31 Manifold: Side Ported 91.7 [96.1] Approx. 300 (Lead wire length) SS5YJ3-S31Stations -M3 L1 L2 3.5 2-3.5 (For mounting) Manual override M5 x 0.8 (P, R port) 5.2 29.2 7.5 52.2 [54.4] 51.4 [53.6] 17.3 30 3 91.7 [96.1] 78.8 [83.2] 78.8 [83.2] 13.5 A A A A A B B B B B P R P R P R 29.2 P R 30 17.3 25 7.5 12 25 51.4 [53.6] 52.2 [54.4] 13.5 B B B B B A A A A A 3 5.2 2-3.5 (For mounting)
Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
The flow rate characteristics correspond to the standard supply pressure (0.5MPa). -90 -80 -70 Vacuum pressure [kPa] -60 -50 -40 -30 -20 -10 0 0 5 10 15 20 25 Suction flow [L/min(ANR)] Flow rate characteristics Exhaust characteristics * The actual suction flow at the point of suction varies depending on the piping conditions to the vacuum port.
The flow rate characteristics correspond to the standard supply pressure (0.5MPa). -90 -80 -70 Vacuum pressure [kPa] -60 -50 -40 -30 -20 -10 0 0 5 10 15 20 25 Suction flow [L/min(ANR)] Flow rate characteristics Exhaust characteristics * The actual suction flow at the point of suction varies depending on the piping conditions to the vacuum port.
AMH AME AMF ZFC SF SFD LLB AD GD 101
Port size IDFA Port size Rc, NPT, TSJ, UOJ 1/4 02 Symbol IDFB Model size IDH Symbol Rated flow rare L/min(ANR) 10 20 30 Up to 26 Up to 70 Up to 140 Elements are replaceable. ID IDG Connection IDK Symbol Connection (IN, OUT) 0 1 2 3 Rc NPT TSJ UOJ AMG AFF SFA302 AM AMD SFA103 Model SFA200 AMH Model Rated flow rate L/min (ANR) Note 1) Element part no.
Switch 100 kPa 0 100 kPa 500 kPa 1 MPa Pressure range 100 kPa 100 kPa For vacuum/ low pressure ZSE30 101 kPa 101 kPa 1 MPa 0 For positive pressure ISE30 100 kPa (0.1 MPa) 1 MPa Rated pressure range of switch Regulating pressure range of switch 16-2-14
120 78 x 25 19 EM 57 39 9 89 59 Y 121 79 y 26 1A SUB 58 3A : 90 5A Z 122 7A z 27 1B ESC 59 3B ; 91 5B [ 123 7B { 28 1C FS 60 3C < 92 5C \ 124 7C | 29 1D GS 61 3D = 93 5D ] 125 7D } 30 1E RS 62 3E > 94 5E ^ 126 7E ~ 31 1F US 63 3F ?
Weight g (oz) Model IN side, OUT side ZFC100-04 4 10 (0.35) 11.5 (0.41) ZFC100-06 6 20 (0.70) Metric size ZFC200-06 6 30 (1.05) 21.5 (0.76) ZFC200-08 8 50 (1.75) ZFC101-03 5/32" 10 (0.35) 11.5 (0.41) ZFC101-07 1/4" 20 (0.70) Inch size ZFC201-07 1/4" 30 (1.05) 21.5 (0.76) ZFC201-09 5/16" 50 (1.75) Note 1) Flow rate when initial pressure drop is 0.003MPa (0.44psi) or less.
It can cause damage or air leakage. 100 8 7 to 9 150 1/8 14 12 to 14 200 1/4 17 22 to 24 200 3/8 21 28 to 30 200 1/2 24 Lock Nut Tightening Torque Caution 1. Suitable screw torque for a hexagon lock nut is shown in the table below. For standard installation, turn 15 to 30 using tool, after fastening by hand. Pay attention not to over torque the product.
P.38 Change of description about filter element. 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2013 SMC Corporation All Rights Reserved 59 -
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Caution To replace the batteries, turn the power OFF and replace them within approximately 30 seconds. When not completed within 30 seconds, Err will be displayed. In that case, perform zero clear once again.
Caution To replace the batteries, turn the power OFF and replace them within approximately 30 seconds. When not completed within 30 seconds, Err will be displayed. In that case, perform zero clear once again.
50 70 100 .001 10 30 50 70 100 Q (l/min) Q (l/min) Filtration Efficiency (Initial Value) Fluid: Potable water Flow rate: 20l/min Liquid temperature: Room temperature Test dust: AC course Amount of dust: 0.2mg/min Test method: Per P/A test method (sanitary test stand, HIAC particle counter) 100 100 ) m ) ) m m 0 ) 0 m (2 (2 (5 (5 20 20 05 05 -0 S0 S0 S0 0S 00080 N-1 N-1 80 N-1 -1 1N 101
Auto switch precautions P.30 1) Applicable auto switches P.30 2) Precautions for use P.32 -1- 3A 3/5 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
(Even if SEL key is not pressed, the value is automatically registered 3 seconds later) SV * Specified temperature range for the outlet air is 15 to 30. 32 IDH Series 3.3 Outlet air temperature setting IDX-OM-W037 Thermo-dryer 3.
Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.
No.PS-OMT0001CN-E // ISA3-A/B2 OUT1 OUT2 or 2 7 8 14 15 (ISA3) 15 () 17 (2 ) 17 18 21 27 27 30 35 39 42 43 45 OUT1 OUT2 45 OUT1 45 OUT2 46 47 47 48 48 48 () 62 63 64 65 66 67 -1No.PS-OMT0001CN-E 1 (ISO/IEC)(JIS) 1) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating