Do not apply external force to the coil. Apply a wrench to the exterior surface of the piping joint at the time of tightening. 3. Do not use heat insulators, etc. to keep the temperature at the coil assembly. Do not use a tape heater for freeze prevention except on the piping and body. If may cause the coil to burn. 1.

12-13-18 D-Y7NW/Y7PW/Y7BW D-Y7NWV/Y7PWV/Y7BWV 12-13-19 Direct Grommet D-F9NW/F9PW/F9BW D-F9NWV/F9PWV/F9BWV 12-13-20 D-F59W/F5PW/J59W Tie-rod Grommet D-F79F 12-13-21 Grommet Rail D-F59F Rail D-F7BAL/F7BAVL 12-13-22 Tie-rod D-F5BAL Grommet D-Y7BAL 12-13-24 Direct D-F9BAL 12-13-23 D-F7NTL Rail Grommet Tie-rod D-F5NTL Note) As for the applicable auto switches on Rotary Actuators, refer

12-13-18 D-Y7NW/Y7PW/Y7BW D-Y7NWV/Y7PWV/Y7BWV 12-13-19 Direct Grommet D-F9NW/F9PW/F9BW D-F9NWV/F9PWV/F9BWV 12-13-20 D-F59W/F5PW/J59W Tie-rod Grommet D-F79F 12-13-21 Grommet Rail D-F59F Rail D-F7BAL/F7BAVL 12-13-22 Tie-rod D-F5BAL Grommet D-Y7BAL 12-13-24 Direct D-F9BAL 12-13-23 D-F7NTL Rail Grommet Tie-rod D-F5NTL Note) As for the applicable auto switches on Rotary Actuators, refer

1 4 11.11 12 10 13.6 39 35 1 8 Reference dimensions after NPT thread installation.

to plug connector Y 24 VDC and 12 VDC are applicable to 0.45 W.

Do not drop or bump. Do not drop, bump, or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

Do not use the product in the presence of a magnetic field. Malfunction can result. Do not let foreign matter, such as wire debris, get inside the product. Otherwise it can cause damage or malfunction. Do not use the product in an environment that is exposed to temperature cycle.

Do not use tools on the pressure regulator knob as this may cause damage.

Force Output Calculation Q: How do I figure out the theoretical force output of a cylinder? A: Follow these steps. 1. Calculate the area of the cylinder piston Area = r2 where = 3.1416 r = 12 the bore diameter 2. Multiply the piston area by the air pressure to be used.

Force Output Calculation Q: How do I figure out the theoretical force output of a cylinder? A: Follow these steps. 1. Calculate the area of the cylinder piston Area = r2 where = 3.1416 r = 12 the bore diameter 2. Multiply the piston area by the air pressure to be used.

Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.

Electromagnetic brake interlock MBR CN3-13 DO-1 PD07 0005 Forced stop EM1 CN3-20 DI-1 (Fixation) (Fixation) Device 1 DI1Note1 CN3-2 DI-1 In-position (Positioning completed) INP CN3-9 DO-1 PD08 0004 (Fixation) (Fixation) Device 2 DI2Note1 CN3-12 DI-1 (Fixation) (Fixation) Trouble ALM CN3-15 DO-1 PD09 0003 Device 3 DI3Note1 CN3-19 DI-1 (Fixation) (Fixation) Devices can be assigned for DI1 DI2

surge voltage suppressor) Nil A B C D E F G H K L Z Rc, One-touch fitting2 G NPT Rc, One-touch fitting2 Grommet Grommet (With surge voltage suppressor) 1E 12 VDC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 12 VDC 1F 1G 1H 1V 1J 1K 1L 1M 1W 1N 1P 1Q 1R 1Y 1S 1T G NPT G NPT Rc, One-touch fitting2 DIN terminal (With surge voltage

Check if there is a noise source An over current (2)Check if the power supply error (Er1 and 2) is indicated. voltage is in the range of 12 to 24 VDC. (2)Supply power voltage of 12 to 24 VDC.

(Do not move beyond the operating limit position.)

Especially when the switch supports the piping, do not apply a load of 15Nm or more to the metal part of the switch. 12. Be sure to allow straight pipe length that is minimum 8 times the port size upstream and downstream of the switch piping.