IS*-OMX0095-B PRODUCT NAME Pressure Switch Pressure Switch with T-Spacer Pressure Switch with L-Piping Adapter Pressure Switch with Piping Adapter MODEL / Series / Product Number IS10M-(20,30,40,50,60)(-1,6,L,P,Z)-D IS10T-(20,30,40,50,60)-(F,N)(-6,L,P,Z)-D IS10L-(20,30,40,50,60)-(F,N)(-6,L,P,R,Z)-D IS10E-(20,30,40,50,60)-(F,N)(-6,L,P,R,Z)-D Contents Page 1. Safety Instructions 2-7 2.
VS3135 A01-01 A01-02 A07-52 q Description Electrical entry VS3145 Solenoid cover Body 100 VAC 200 VAC Grommet A12-01 A12-02 A08-52 w e Spool/Sleeve 24 VDC A01-01-63 A01-02-63 A07-52-63 100 VAC 200 VAC Conduit terminal 24 VDC A12-01-63 A12-02-63 A08-52-63 Replacement Parts Material Part no. VS3135 XT019-6 XT013-13-2 XT010-15 Description VS3145 No.
25 M For positive pressure ZSE30 01 25 M For vacuum/Low pressure Option 2 Piping specification R 1/8 (with M5 female thread) NPT 1/8 (with M5 female thread) 01 T1 None Bracket Nil A Output specification NPN output PNP output 1 to 5V output 4 to 20mA output 25 65 26 28 Panel mount B Unit specification Nil M With unit switching function Fixed SI unitI (International System of Units) Note)
Material Applicable blow gun model Model Male thread nozzle 1 to 2.5 Male thread nozzle 3 to 4 Width across flats 17 Nozzle type P5670129-01 P5670129-01F P5670129-02 P5670129-02F HNBR Fluororubber HNBR Fluororubber VMG1mm-m-01 to 04 VMG1mm-m-05 to 07 m25 VMG1m-mm-1 to 04 Width across flats 17 m23.5 VMG1m-mm-05 to 07 Cover for copper extension nozzle (mm) Nozzle cover part no.
If the power should not come back on, please contact P/A for an inspection.
AL.01 Contact output 2 function Sets output signal function of contact output 2. RMT Contact output 2 operation Sets output signal operation of contact output 2. A Contact output 2 selected alarm Sets alarm which is selected for contact output 2. AL.01 Contact output 3 function Sets output signal function of contact output 3.
AL.01 Contact output 3 function ALM Contact output 3 operation B Selected for contact output 3 AL.01 5.2 Function HRS Series 5-6 HRX-OM-R005 Chapter 5 Display and setting of various functions 5.3 Main screen 5.3.1 Main screen Displays the current temperature and the set temperature of the circulating fluid.
Setting of the selected alarm Setting range: AL.01 to AL.51 to 63. Press the [MENU] key once. Returns to the main display (which shows the circulating fluid temperature).
220-01-F 220-02 220-02-F 320-03 (02) 320-03-F (02) 420-04 420-04-F 121F-M3 131F-M3 121F-M5 (U10, 32) 131F-M5 (U10, 32) 221F-01 231F-01 2211F-01-06 221F-02 231F-02 321F-03 (02) 331F-03 (02) 421F-04 431F-04 1000F 2000F 2050F 3000F 4000F 1001F 2001F 2051F 3001F 4001F 230F 330F 430F 530F 630F 330F 430F 530F 630F Manifold regulator 4-, 5-port solenoid valve VQ Directional control valves 0 1000
Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% 1 Electric spec.
VH*-OMX0068-C PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40-(F,N)02~(F,N)04(-B,S)(-K,M,R,Z)-D VHS40-(F,N)06(-B,S)(-K,M,R,Z)-D VHS50-(F,N)06~(F,N)10(-B,S)(-K,M,R,Z)-D VHS20W-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30W-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40W-(F,
Electrical entry q Description 01 02 03 01 02 03 01 02 03 Mounting bolt and gasket are not included. Platinum silver Body C: Conduit VS4010-CSSub-plate Platinum silver Aluminum die-casted w T: Conduit terminal VS4010-TSSpool/Sleeve Stainless steel e U: Grommet, D: DIN terminal VS4010-SReplacement Parts Part no. No.
vacuum) (compound) (positive pressure) Rated pressure range 0.0 to -101.0 kPa -100.0 to 100.0 kPa -0.100 to 1.000 MPa Set pressure range 10.0 to -105.0 kPa -105.0 to 105.0 kPa -0.105 to 1.050 MPa Withstand pressure 500 kPa 500 kPa 1.5 MPa Minimum display unit 0.1 kPa 0.1 kPa 0.001 MPa Applicable fluid Air, inert gases and incombustible gases Power supply voltage 12 to 24 VDC 10%, ripple (p-p
OFF state { A R1 (Exhaust air) P B (Supply air) F1 < F2 condition: See figure q. ON state { { Immediately after turning on F1 > F2: See figure e.
LVC DIN terminal: D Conduit terminal: T Cable 6 to 12 LVA F S Q 27.5 34 F (Q) LVH LVD LVQ LQ R C U 25 LVN C (44) R E R TI/ TIL G1/2 E PA G1/2 A H D (S) B B A H D 2-P Port size 2-P Port size PAX 2-M Thread depth N 2-M Thread depth N PB L L K K N.C.
Nil P NPN specification PNP specification Cable full length 1 m 2 m Symbol 01 02 Individual Special Order (Please contact an SMC sales representative.) Note 1) 11 m or longer power supply cables are not CE Marking-compliant. Note 2) Use standard power supply cables for 3 m and 10 m lengths.
P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4x20) with washer, 1 pc. P tight screw (4 x 14), 2 pcs. (3)Intermediate support bracket EX600-ZMB1: For direct mounting Enclosed parts: Round head screw (M4 x 5), 2 pcs.
P tithe screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc. P tithe screw (4 x 14), 2 pcs. (3) Intermediate support bracket EX600-ZMB1for direct mounting Enclosed parts: Round head screw (M4 x 5), 2 pcs.