Incorrect operation of the internal data of the Pressure switch (Er0, Er4, Er6, Er7, Er8, Er9) System error (Er0, Er4, Er6, Er7, Er8 or Er9) is displayed. (2) Check that the power supply voltage is within the range 12 to 24 VDC 10%. (2) Supply a correct voltage of 12 to 24 VDC 10%.
Settings and Data Entry 38 10.1 Step Data 38 10.2 Basic parameters 41 10.3 Return to origin parameter 43 11.
min (250 L type) [ P_2] Set value (OUT2) [F 2]/[ oUt2] Page 37 5% of max. rated flow [ 0.20] 0.20 L/min (4 L type) [ 0.8] 0.8 L/min (16 L type) [ 2.0] 2.0 L/min (40 L type) [ 5] 5 L/min (100 L type) [ 12] 12 L/min (250 L type) [ H_2] Hysteresis (OUT2) [F 3]/[ RES] [ rES] Response time setting [ 1 .00] 1 second Page 41 [F10]/[ SUb] [ SUb] Selection of sub screen [ oUt] Display of set value
PAP: Clean room LVH Note 1) 1 to 12 l for 3/8" tubing type. Note 2) The above values are for a normal temperature and using clean water. LVD Refer to the separate pamphlet P-E00-5A for further details.
Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04
U side 1 2 3 4 5 6 7 8 n 2-C10 R(EXH) port DIN rail clamping screw EXH EXH SMC SMC SMC SMC SMC SMC SMC 2-C10 P(SUP) port R R X B B B B B B B B X P 49 P 31.6 9.5 24.5 16 A A A A A A A A (12) (7.5) 23 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 threads 41 P = 16 Broken lines and dimensions inside ( ) indicate type [-D] (with
Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04
AS23 1FE-01 AS22 1FE-02 AS23 1FE-02 AS32 1FE AS33 1FE AS42 1FE AS43 1FE Model 8 10 6 8 10 12 12 10 6 8 10 Tubing O.D.
, Ion exchange resin*12 Temperature range [C] 5 to 40 Pressure range [MPa] 0.3 to 0.5 Required flow rate (50/60 Hz)13 [L/min] 8 12 Facility water system Inlet-outlet pressure differential of facility water [MPa] 0.3 or more Port size Rc3/8 Fluid contact material Stainless steel, Copper (Heat exchanger brazing), Bronze, Synthetic rubber Power supply Single-phase 100 VAC (50/60 Hz), 115 VAC
6 1.6 115 106 M N O P Q R S T U LFE13 48 39 4.6 12 11.5 52 28 2.5 8.5 2 45g LFE14 48 39 4.6 12 11.5 52 28 2.5 8.5 2 45g LFE26 62 53 4.6 9.5 14 56 38 2.5 8.5 2.6 70g LFE38 62 53 4.6 3.5 20 68 43 2.5 8.5 2.6 70g 8mm0.70.8Nm 71 No.LFE*-OMY0008 M12 M12 M12 M12 (LFE (LFE (LFE (LFE-1 1 1 1-A3) A3) A3) A3) ( ( ( ( )3 )3 )3 )3 4( 4( 4( 4( ) ) ) ) ( ( ( ( )2 )2 )2 )2 1( 1( 1( 1( ) ) )
Roller lever VM430-01-01 VM430-01-01S JIS Symbol 17 polyacetal or hard steel roller 4.0 mm P.T. 12 N F.O.F. 4-4.5 mounting hole 4.5 mm O.T. 8.5 mm T.T. One way roller lever VM430-01-02 VM430-01-02S JIS Symbol 17 polyacetal or hard steel roller 4.0 mm P.T. 11 N F.O.F. 4-4.5 mounting hole 5.0 mm O.T. 9.0 mm T.T.
AS2200-01-X12 Ex.) AS2200-01-X21 Note 1) Not particle-free Note 2) Throttle valve is only compatible with the part no. of the meter-out type. Throttle Valve (Without Check Valve) X214 Ex.)
] :01 06 0050 0 A9 [CR][LF] Stop 0050 Control operation mode 1 :01 06 0050 0001 A8 [CR][LF] :01 06 0050 0001 A8 [CR][LF] Start 0051 Temperature setting 1 :01 06 0051 0BB8 E5 [CR][LF] :01 06 0051 0BB8 E5 [CR][LF] Set at 30.0 deg.C. 0052 Offset setting 1 :01 06 0052 0032 75 [CR][LF] :01 06 0052 0032 75 [CR][LF] Set at 0.50 deg.C.
Applicable tubing O.D. d AS221FE-01-04SK 12.7 27.5 20.4 4 9.3 26 AS221FE-01-06SK 13.5 14.3 27.5 20.4 6 11.6 27 (Hexagon width across flats) R 1/8 12 12 44.9 49.9 48.9 53.9 14.2 AS221FE-01-08SK 18.5 32.4 25.3 8 15.2 29 (Hexagon width across flats) AS221FE-01-10SK 15 21 40.2 33.1 10 18.5 31 AS221FE-02-04SK 16 34.4 25.2 4 10.4 36 AS221FE-02-06SK 18.2 17 34.4 25.2 6 12.8 37 R 1/4 17 14 41.2 46.2
Stations Note 1 station w Manifold model Double wiring Note 1) i Option 1 Plug-in unit 12 01 12 stations 1 station Nil S K None Built-in silencer, Direct exhaust Note 1) Specified layout Note 2) (Available up to 24 solenoids) r Cylinder port size Special wiring spec.
15 24 31 42 37 41 79 100/200 100/200 100/200 100/200 100/100 100/100 100/100 50/100 ** Non-Standard Product, consult factory for lead time.
operated Pilot solenoid VEX3 B 12 0 01 1 Air operated VEX3 D B 5 1 12 2 01 Pilot solenoid Operation type Option 1 External pilot solenoid 2 Internal pilot solenoid Nil None Thread type Nil Rc F G N NPT T NPTF Body size Port size B Bracket (VEX312 only) Body size Port size Port 1(P), 2(A), 3(R) 12 01 1/8 02 1/4 Rated voltage VEX312 VEX332 1 100 VAC (50/60 Hz) 2 200 VAC (50/60 Hz) 3 110 VAC
Setting of switch operation 1_P/1_N (page 37) (Selection of display colour) Setting of Add dEC1 dEC2 (page 41) 3. Input of set values Setting of Setting of P1L/n1L Setting of P_1/n_1 P1H/n1H P1/n1 H_1 WH1 (page 40) (page 37) (page 39) 4. Delay time Setting of dtH1(ON) dtL1(OFF) (page 38) 5. Selection of display colour rED/Grn/1SoG/1Sor/2SoG/2Sor (page 41) 6.
Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the origin is changed from 2 to 1. Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) -28-
16 20 8 24 2 4 6 8 10 12 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (for PA3000) PA313 Air consumption 160 Required specification example: Find the pilot air pressure for a discharge rate of 4l/min and a total lifting range of 15m.