to 800 19 19 19 19 23 23 27 27 31.5 31.5 38 38 35 40 43.5 43.5 56 56 1/8 1/4 1/4 3/8 3/8 1/2 11 11 11 11 21 21 92 97 106 106 132 132 4 4 5 9 11.5 17 6.5 9 10.5 12 14 15 24 24 24 24 40 40 143 152 168 168 208 208 100 110 118 118 150 150 151 165 180 180 226 226 6-6-37 37 Series MBB With Mounting Bracket Foot(L)/Locking at head end (-H) -W -H/ -R (mm) Port Cushion valve Stroke range Bore size
37 13 72 62 76.5 M10 x 1.5 10 30 16 5 100 37 26 40 114 89 30 16 55 20 19 37 16 72 71.5 86 M10 x 1.5 10 30 16 5 -Wl Bore size [mm] MM MO N NB P RF S V W WL ZZ S ZZ 32 M10 x 1.25 15 27 35 1/8 11 92 4 6.5 24 143 40 M14 x 1.5 19 27 40 1/4 11 97 4 9 24 152 50 M18 x 1.5 19 31.5 43.5 1/4 11 106 5 10.5 24 168 63 M18 x 1.5 19 31.5 43.5 3/8 11 106 9 12 24 168 80 M22 x 1.5 23 38 56 3/8 21 132 11.5
L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tubing O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.
Round head screw (M3 x 8) , 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6) , 2 pcs. Round head screw (M3 x 8) , 4 pcs. (2) End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20) , 1 pc. P tight screw (4 x 14) , 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.
Remove pilot valve mounting screws (M3, 2 pcs.), rotate the pilot valve at 180 and then re-tighten the valve with the screw.
PF2D5--1 (With voltage output type) PF2D540-19 Display unit (PF2D30/31) 186 Sensor unit 78 86 Brown 6 2 Analog output Switch output or Pulse output Main circuit Main circuit 56 8 4 Load + 12 to 24 VDC 15 White 7 3 Black 5 1 Blue Load is an analog input equipment such as a voltmeter.
ZQ-OM01401-B / / ZQA No.ZQ-OM01401-B 2 1. 5 2. 9 3. 11 3.1. 11 3.2. 12 3.3. 13 3.4. 14 3.5. 16 4. 17 5. 19 6. 20 7. 21 8. 28 9. 32 10. 35 11. 37 12. 40 13. 42 1 - No.ZQ-OM01401-B /ZQA *1) *2) (ISO/IEC)(JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery
Unit Note 9) Instantaneous flow L/min, cfm (ft3/min) Accumulated flow L, ft3 Displayable range Instantaneous flow 25 to 525 L/min (Displays [0] when value is within 4 to 4 L/min range.) 50 to 1050 L/min (Displays [0] when value is within 9 to 9 L/min range.) 100 to 2100 L/min (Displays [0] when value is within 19 to 19 L/min range.)
Never use pressure sensors in the presence of inflammable or explosive gases. 16-3-19 19 Series PSE Specific Product Precautions 2 Be sure to read before handling.
Real-time switch output ( ) Unit switching Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ZSE ISE ON YES OFF P-1 P-2 GPM gal (US) PSE Real-time flow rate GPM = gal (US)/min P Window comparator mode H: Hysteresis Z I SE3 Note) Fixed SI unit (l/min, l, m3 or m3 x 10) will be set for the type without the unit switching function.
Nickel plated Spring washer Steel wire @3 Felt Felt @4 Holder Stainless steel @5 8-21-19 19 Series MGG Construction 63 to 100/MGGB #3 !5 #6 q t #8 !4 !7 @2 @3 @4 r y e #7 u o !1 i w !8 #4 !6 A @0 @1 !9 #2 !
HRR Series 3.4 Piping 3-19 HRX-OM-W002 Chapter 3 Transport and Setting Up [Tips] For HRR012/018/024/030-AN-20-HRR012/018/024/030-WN-10/20A set of thread adapters that converts the connections from Rc to NPT is enclosed as an accessory. For NPT thread, be sure to use this adapter.
Alarms that allow continuous pump operation are shown in Table 5.4-18 Alarms that allow continuous pump operation (1/2) and Table 5.4-19 Alarms that allow continuous pump operation (2/2).
HRR Series 3.4 Piping 3-19 HRX-OM-X084 Chapter 3 Transport and Setting Up [Tips] For HRR010-AN-10/20-,HRR010-WN-10/20A set of thread adapters that converts the connections from Rc to NPT is enclosed as an accessory. For NPT thread, be sure to use this adapter.
-inch rack (EIA standards1). 1 19-inch Rack Standards Standard EIA (Electronic Industries Alliance) 500 mm Standard no.
VHK-B2A 49 17 1 30 25 21.5 31 VHK-03S-03S 3 8 3 8 3 8 19 VHK-04S-03S 22 46 93 48.7 44.3 48.7 97.4 21.5 4 14 15.1 17.5 3.2 90 19 22 101 79 81 22 VHK-B2A 49 17 1 30 25 21.5 31 VHK-04S-04S 1 2 1 2 3 port valve Reference dimensions after insertion of R thread. 5-8-4 5 Finger Valve Series VHK Piping Precautions Caution Be sure to read before handling.
Required facility water system (for water cooled type) Table 3-2 Facility water source to be prepared Required facility water flow rate Heat Facility water temp. l/min range Model Radiated Facility water temprature oC kW 25 32 35 40 5 to 40 16 19 27 HRR050-W-20(Rating 25) Approx.10 HRR050-W-405 to 35 16 19 22 (Rating 25) HRR Series 3.2 Installation 3-5 HRX-OM-X071 Chapter 3 Transport and
No.JXC-OMT0005CN-A DeviceNet (DC24V) // JXCD1 1. . 4 2 . 6 2.1. . 6 2.2. . 7 2.3 . 8 2.4 () . 9 1 . 9 2 . 9 3 . 9 4PLC . 9 5 . 9 6 . 10 7 . 10 8() . 11 9 . 11 3 . 12 3.1. . 12 3.2 . 13 3.3. . 14 3.4. . 16 (1) . 16 (2) . 16 (3) . 17 4 . 18 4.1 Node Address/Data Rate . 18 4.2 . 19 4.3 DeviceNet . 19 1Step Data Class 67h . 19 2IO Class 68h . 20 3IO . 21 4IO . 21 5 . 23 5.1 PWR
71 43 19 14 190 230 15 M14x1.5,15 13 0125 Up to 1000 50 47 143 145 17 15 27 171 27 . t3 128 20 212 112 255 '15 'UpJo.1 QOO 50 47 157 1060 32 19 15 43 M14n.. ?