51 37 41 50 41 45 57 42 43 53 72 78 KA 4 2.5 1.8 1.6 10 8 13.5 5 4 3 KQG2 2.3 2.6 Applicable tubing L1 M 6 4 6 10 10 15 5.8 3.3 KG H1 12 d 8 6 KFG2 KFG2 5.3 12 14 17.4 6.6 16 22.2 A L2 23 H2 MS 25.6 10 7.5 6.8 26 Connection thread 27.5 15 17 20.9 7.6 KKA 27 25.6 10 8 7.3 30 KP 27.5 27 25.6 12 9 8 LQ 35 27.5 16 17 23.5 8.5 34 MQR 25.6 12 10 9 44 27.5 31 32.9 T 16 13 79 12 21 22 26.2 9.3 IDK
67 103 130 194 261 329 4000 13 38 63 94 119 175 240 310 rods should not be considered a remedy against excessive side loads. 5000 9 34 60 87 110 163 225 289 6000 5 30 56 82 102 152 208 274 8000 4 26 50 76 93 137 188 245 10 3 21 45 70 89 125 172 222 12000 17 41 65 84 118 155 210 16000 9 34 57 75 110 142 188 HOW TO USE THIS TABLE 20 8 28 52 68 103 136 172 30 5 12 39 55 87 120 156 40 11 22
Setting of switch operation 1_P/1_N (page 37) (Selection of display colour) Setting of Add dEC1 dEC2 (page 41) 3. Input of set values Setting of Setting of P1L/n1L Setting of P_1/n_1 P1H/n1H P1/n1 H_1 WH1 (page 40) (page 37) (page 39) 4. Delay time Setting of dtH1(ON) dtL1(OFF) (page 38) 5. Selection of display colour rED/Grn/1SoG/1Sor/2SoG/2Sor (page 41) 6.
PV SV HRSH Series 5.17 Pump Operation Mode Setting 5-41 HRX-OM-Q026 Chapter 5 Display and Setting of Various Functions 5.18 Warming Up Function 5.18.1 Warming up function Keep the power supply ON for this function. This function does not operate when the power is OFF.
25.40 25.40 30.00 30.00 30.00 21.7 21.7 19.2 22.2 22.7 21.7 26.0 30.7 33.2 28.7 26.2 34.2 32.7 29.7 38.6 37.9 47.5 50.5 52.5 17.6 17.6 13.4 18.1 16.9 15.6 17.8 26.6 27.4 22.6 18.1 28.4 26.6 21.6 32.5 29.8 41.4 42.4 43.9 16 16 16 17 17 17 17 21 21 21 21 22 22 22 25 25 33 33 33 1.6 1.6 1.6 3.5 3.5 3.5 3.5 5.4 5.4 5.4 5.4 8.5 8.5 8.5 9.8 9.8 12.8 12.8 12.8 8 9 14 8 14 24 54 23 27 25 42 40 40 41
I '-1 'N . ,." " H1 H2 01 02 03 l1 M odel ~ T1 T2 ' ~ f . 9 4 ' 3 ~9 . 2~q .. ~ " 6 8" 41,-'1; " W }?'.." 48.7' 42.6, 10.9 46.4 2B,2 " . . '118:'7 ~7 .3 .70~ .2M .. Ii' .. , . t ~ .230 42.2 25.8 38.9 ' 39.5 33.9 44.7 28.2 35. 1 10.5 17 ~ 35 A SP330F-N01-07S 1/4" NPT1 /8 10-32UNF ASP330F-N01 -09$ 5/16" ~ 14.2 118 15.8 15 .2 :.g 1/2' 8 NP'W~ " ~ NE?'T, lta ".,I:SP'43oFi!
Hold down again for 1sec. or longer after interval No.DIG-31900-OM002 51 Mode button 1s Set button 1s or Mode button 1s Set button 1s or Mode button 1s Mode button 1s Set button Set button 1s 1s E F Fig. 41 E Mode button 1s Set button 1s or Lower limiter Upper limiter Fig. 41-1 F Mode button 1s Set button 1s Alarm setting Fig. 41-2 No.DIG-31900-OM002 52 Possible to select set
SV 41. Set the product operation when "Pump maintenance" alarm is generated with [] key or [] key, and press [SEL] key to enter. Table 5.20-28 Operation setting when "Pump maintenance" alarm is generated Set value Explanation Default This alarm is not detected.
(Refer to page 166.) 3 position closed center 3 position closed center 4(A) (B)2 4(A) (B)2 Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. 5(R) 1 (P) (R)3 3(R) 1 (P) 3 position exhaust center 3 position exhaust center 4(A) (B)2 4(A) (B)2 (Example) SS5YJA3-41-03-M5 1 pc.
Setting of switch operation 1_P/1_n (page 41) (Selection of display colour) Setting of Add dEC1 dEC2 (page 45) 3. Input of set values Setting of Setting of P1L/n1L Setting of P_1/n_1 P1H/n1H P1/n1 H_1 WH1 (page 44) (page 41) (page 43) 4. Delay time Setting of dtH1(ON) dtL1(OFF) (page 42) 5. Selection of display colour rED/Grn/1SoG/1Sor/2SoG/2Sor (page 45) 6.
manifold assembly: sta. 1-4) NZXl101-KlsLZ-EC-M NZZXlO4-TB-A Parl Number / Configuration Six station manitold assembly: sra. 1) NZX 1071 -K3sMZ-F-M sta. 2-5) NZX1071-K1sLZ-EC-M sta. 6) zx'l-BABI NZZXl O6-TB-A 4tl 2 ' Part Number / Configuratlon Four station manifold assembly: sta. 1-2) NZX'I101-EC-M zx1-DR1-4 sra.3-4) NZXi071-EC-M zxl-DR16-4 NZZXl04-TB-A r:::r:l::t: l:l:l:lrrl:l:l:l :r:t:41
(SeeLECSS Operation Manual (Simplified Edition),section 6.3.2 for uploading.) -41- 6.8.2 To Load saved Parameters From the Project menu in the setup software, select Open. Please select the "drive path name project name" that you want to read parameters from. Click Open.
A 09 9N 9P BO (mm) Without boot With boot ,, ZZ+t+SlroItQ MM J 00 oE F GA GB GC GO GL GR J K L L2 16 32 10 85 15 26 54 10 10 M8xl.2S 6 30 71 40 500 20500 27 30 60 96 y. Y. 44 M14X l .5 M18X l .5 M\8X l .5 M22Xl.5 M26X1.5 , 50 -600 20-600 32 35 70 108 Y. Y. 52 63 !
Valve Direction: Single Solenoid Coil on Opposite Side of A and B Ports, Stations: 04, A, B Port Size: N3 (One-touch Fitting for ø5/32"), P, R Port Thread: T (NPTF)
Valve Direction: Single Solenoid Coil on Opposite Side of A and B Ports, Stations: 04, A, B Port Size: One-touch Fitting for ø5/32", P, R Port Thread: NPTF
Operation at occurrence of circulating fluid discharge pressure rise alarm RUN HIPRS ALARM(Alternately displayed) HRR Series 5.5 Advanced setting mode 5-33 HRX-OM-X084 Chapter 5 Display and Setting of Various Functions The user can decide the chiller behaviour if alarm "AL 09: circulating fluid discharge pressure rise" occurs.
HRR Series 5.5 Advanced setting mode 5-41 HRX-OM-X071 Chapter 5 Display and Setting of Various Functions Contact input signal 2 delay timer 24. Press the [] key. Displays screen for setting the Contact input signal 2 detection delay timer for reading. Time for starting detection of the contact input signal 2 (sec) can be set. Setting range: 0 to 300sec. (Initial value: 0sec.)
A 1.18 (30) 1.61 (41) B 1.34 (34) 1.57 (40) C D E F G 136314 2.76 (70) 2.97 (75.5) .21 (5.4) .26 (6.5) .61 (15.4) .31 (8) 2.17 (55) 2.09 (53) .09 (2.3) .09 (2.3) NARM2500 43.5 136414 NARM3000 30 15 Precautions 0 35.3 70.6 106 Be sure to read before handling.
63 71 75 Single Double Closed center Exhaust center Pressure center Dual 3 port valve Single Double Closed center Exhaust center Pressure center Dual 3 port valve Single Double Closed center Exhaust center Pressure center Dual 3 port valve 43 46 50 2 position 2 position C2 C2 SJ3l60-C2 SJ2l60-C2 2 onetouch fitting 2 onetouch fitting 3 position 4 position 3 position 4 position 71 65 73 46 41
(Manifold specification sheet on page 41.)