Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 5 Port/Base Mounted Common SUP Individual EXH, Stations: 17 Stations, A B Port Size: Base Mounted M5X0.8, P R Port Thread: -
Valve Mounting Direction: Single Solenoid Coil on the Same Side as A,B Ports, Piping: 4 Port/Base Mounted Common SUP Common EXH, Stations: 17 Stations, A B Port Size: 5/32" One-touch Fitting NPTF, P R Port Thread: -
Valve Mounting Direction: Single Solenoid Coil on the Same Side as A,B Ports, Piping: 5 Port/Base Mounted Common SUP Common EXH, Stations: 17 Stations, A B Port Size: Base Mounted M5X0.8, P R Port Thread: -
Valve Mounting Direction: Single Solenoid Coil on the Same Side as A,B Ports, Piping: 4 Port/Base Mounted Common SUP Common EXH, Stations: 17 Stations, A B Port Size: Base Mounted M5X0.8, P R Port Thread: -
Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 5 Port/Base Mounted Common SUP Common EXH, Stations: 17 Stations, A B Port Size: Base Mounted M5X0.8, P R Port Thread: NPTF
Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 5 Port/Base Mounted Common SUP Common EXH, Stations: 17 Stations, A B Port Size: 5/32" One-touch Fitting NPTF, P R Port Thread: -
Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 5 Port/Base Mounted Common SUP Individual EXH, Stations: 17 Stations, A B Port Size: Base Mounted M5X0.8, P R Port Thread: NPTF
Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 5 Port/Base Mounted Common SUP Individual EXH, Stations: 17 Stations, A B Port Size: 5/32" One-touch Fitting NPTF, P R Port Thread: -
Series: 1 (JSY1000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 2 (1.5m), Valve Stations: 8 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 1 (0.6m), Valve Stations: 8 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 5 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 1 (0.6m), Valve Stations: 6 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 2 (1.5m), Valve Stations: 7 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 2 (1.5m), Valve Stations: 8 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 6 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C4 (ø4 One-touch Fitting)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 2 (1.5m), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting)
10)C4 (One-touch fitting for ?4) C6 (One-touch fitting for ?6) C8 (One-touch fitting for ?8)2 to 10 stations: W = 47n + 15611 to 20 stations: W = 47n + 190
Model: 10 (Side Ported), Number of Cores - Lead Wires: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 3 Stations, P, E Port Locations: D (D Sides), SUP/EXH Block: S (Internal Pilot/Built-in Silencer), A, B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate), DIN Rail Option: 0 (w/o DIN Rail with Bracket)