30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/
or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal
kW Input signal Rated load voltage 48 VAC or less/30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (not usable for inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting
is not provided for the 12 VDC specification.
Current consumption in power supply voltage range 22.8 to 26.4 VDC 2.0 A or less, according to the solenoid valve station specification Solenoid valve power supply Output type PNP (negative common) / source Connected load Solenoid valve with surge voltage suppressor of 24 VDC and 1.5 W or less (manufactured by SMC) Solenoid valve connecting specification Insulation Power supply for SI unit
Setting of the response time may improve the condition. 65 No.PF-OMU0002-D Error indication Problem Possible causes Investigation method Countermeasure Incorrect power supply Check if the power supply voltage is 24 VDC 10%. Power supply voltage is 24 VDC 10%.
Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% 1 Electric spec.
Black Continuous Energization (24 VDC) Black 1. Power consumption 80 W specification: Not possible When operating with an energy saving driver, continuous energization with the holding voltage of 3 to 6 VDC is possible. Symbol 2.
valve with surge voltage suppressor of 24 VDC and 1.5 W or less (manufactured by SMC) Insulation type Photo coupler insulation type Residual voltage 0.4 VDC or less -25No.EX-OMN0011-F Network communication specifications Item Specifications Protocol EtherCAT EtherCAT mode Direct Mode (No MAC address) : Does not support Open Mode.
Cable colour: Signal Cable O.D. 5.0 mm 1 Brown : 24 VDC (For solenoid valve) Nominal cross section AWG22 2 White : 0 V (For solenoid valve) 3 Blue : 24 VDC (For control) Wire diameter (Including insulator) 1.27 mm 4 Black : 0 V (For control) 5 Green/Yellow: Not connected Min. bending radius (Fixed) 21.7 mm -31No.EX-OMP0005-I Seal cap For M12 connector socket: 10 pcs.
Supply 24 VDC 10% to the power supply for the input and control.
Current consumption in power supply voltage range 22.8 to 26.4 VDC 2.0 A or less, according to the solenoid valve station specification Solenoid valve power supply EX260-SPR1/-SPR3/-SPR5/-SPR7 PNP (negative common) / source Output type EX260-SPR2/-SPR4/-SPR6/-SPR8 NPN (positive common) / sink Solenoid valve connecting specification Solenoid valve with surge voltage suppressor of 24 VDC and
System error (Er0, 4, 6, 7, 8, 9) is displayed. (2) Check if the power supply voltage is in the range 12 to 24 VDC 10%. (2) Supply power in the range 12 to 24 VDC 10%. "HHH" is displayed. 6 (1) Reset applied pressure to a level within the set pressure range. (1) Check if the pressure exceeds the upper limit of the set pressure range.
condition at the time of communication error Output HOLD/CLEAR Connected load Solenoid valve with surge voltage suppressor of 24 VDC and 1.5 W or less (manufactured by SMC) Insulation type Photo coupler insulation type Residual voltage 0.4 VDC or less -36No.EX-OMP0013-E Communication specifications Item Specifications Protocol Ethernet (IEEE802.3) Transmission medium Standard Ethernet cable
VK300-82-2-01 VK300-82-2-03 110 VAC 110V VK300-82-2-02 200 VAC 200V VK300-82-2-04 220 VAC 220V DIN terminal type VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD Indicator light (Built-in connector) Marking Circuit with indicator light AC circuit diagram 12 VDC or less circuit diagram 24 VDC or more circuit diagram
VK300-37-2-01 VK300-37-2-02 VK300-37-2-07 VK300-37-4-51 VK300-37-4-06 VK300-37-3-05 VK300-37-3-53 A1 A2 A3 LW06 LW2 LD4 LD8 100 VAC 200 VAC 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC 4-13-3 4 For details about the applicable products conforming to international standards, visit us at www.smcworld.com. 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 How to Order Valves Electrical entry
Electrical entry G Body Coil voltage Lead wire length 0.6 m 5: Plug lead sub-plate 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Lead wire length 1.5 m Grommet H Function Nil Y(1) R(2) Standard type (1 W) Low wattage type (0.5 W) External pilot Seal 0 1 Metal seal Rubber seal Note 1) Note 2) Applicable to DC specifications.
, 100 VDC or less 50mA, 40mA, 20mA IC circuit, Relay, PLC No Reed switch D-A90 D-M9B, D-F8B D-M9N, D-F8N 2-wire 3-wire 24 VDC relay, PLC 24 VDC relay, PLC Solid state switch Yes 24 VDC (10 to 28 VDC) 24 VDC (4.5 to 28 VDC) Yes 2.5 to 40 mA 40 mA or less Refer to page 212 for a list of applicable auto switches. 204 Rotary table MSQ 1122Specifications Suction flow rate of vacuum suction type
Voltage AC and 100 VDC 24 VDC or less Terminal no. 1 + () With indicator light With indicator light Terminal no. 1 (+) F.R.L.
) 100 or less (at 12 VDC) Brown LINE(+) Brown DC(+) Load Main circuit Main circuit (Analog output) 1 k Black OUT 12 to 24 VDC + 12 to 24 VDC + Load Blue LINE() Blue DC() Load Install the load either on the LINE (+) or LINE () side.