200 mm/s mm/s LE-CP-#-#-# 100 500 100 500 1 1 200 1000 200 1000 2 2 To MOT 50 200 50 200 3 3 or PC To PWR USB cable (A-miniB type) Part No.
MGQ 12, 16 M L 10, 20, 30, 40, 50, 75, 100 2020, 30, 40, 50, 75, 100 125, 150, 175, 200 Data MGQ 20, 25 M L M L MGQ 32, 40 50, 63 80, 100 25, 50, 75, 100, 125 150, 175, 200 OUT (N) IN (N) Theoretical Output (N) Bore size (mm) Operating pressure (MPa) Rod size (mm) Operating direction Piston area (mm2) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Made to Order Specifications (For details, refer to
200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 Controller power supply To PWR 24VDC PC Power supply plug (Included) or USB cable
JX C D 1 LEFS16B-100B-S1CD17S LEFS16B-100 D DeviceNet DeviceNet 1 1 DC24V S T T 7 8 DIN <> LEHZ10K2-4 < >LECPMJ SVRE 1.5 7 - 2.3 *1 DeviceNet PLC JXC-CD-TJXC-CD-S DC24V P5062-5 *1 LE-CP-LE-CP---S ENC *2 120.3 120.3 mm mm MOT 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 PWR DC24V USB A-miniB type JXC-CPW AWG200.5mm 2
I.D. 427 TU0425-100-X3 TU0604-100-X3 TU0805-100-X3 TU1065-100-X3 TU1208-100-X3 4 6 8 10 12 2.5 4 5 6.5 8 285 Max. operating pressure 142 0 4 32 70 105 140 10Clean Series Operating temperature F Only available in 20m rolls.
, 125, 150 -X 10, 20, 30, 40, 50, 75, 100 125, 150, 175, 200 For long strokes, it will be made-to-order.
N.O. 1 2 3 4 5 6 7 8 J 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz 1 2 3 VXD21 VXD22 VXD23 Symbol Nil 2 Valve Symbol Nil 2 Valve N.C. N.O.
kPa (Detection distance 0.01 to 0.25 mm) 50 to 200 kPa (Detection distance 0.03 to 0.50 mm) Set pressure range 0 to 98 kPa 0 to 0.98 MPa 0 to 101 kPa 100 to 100 kPa 10 to 101.3 kPa 0.1 to 1 MPa 0 to 100 kPa 0 to 1 MPa 0 to 101 kPa 0.1 to 0.45 MPa 0.1 to 0.4 MPa 20 to 101 kPa 101 to 101 kPa 0.1 to 1 MPa 0.4 to 10 MPa 0.5 to 15 MPa 100 to 100 kPa 0.1 to 1 MPa 0 to 1 MPa Voltage 12 to 24 VDC
175 185.5 5 77.5 88 162.5 173 4 67 77.5 150 160.5 3 56.5 67 150 160.5 2 46 56.5 137.5 148 VQ4 25 35.5 112.5 123 L1 L2 L3 L4 VQZ Dimensions/Top entry connector [FU] (mm) VQD n L 1 100 110.5 16 15 250 260.5 14 237.5 248 13 237.5 248 12 225 235.5 11 212.5 223 10 200 210.5 9 187.5 198 8 175 185.5 7 162.5 173 6 162.5 173 5 150 160.5 4 137.5 148 3 125 135.5 2 112.5 123 L3 L4 100 110.5 VZS How
series Cylinder stroke (mm) 80 100 50, 75, 100, 125, 150, 175, 200 50, 75, 100, 125, 150, 175, 200 CKGA series End bracket Nil Y None Double knuckle joint (with tap) CKPA series Note) A knuckle pin, cotter pins and flat washers are provided as a standard for Y.
Additional Weight Ensuring Safety Unit: g Caution 12 13 16 32 20 100 25 100 32 200 40 200 50 350 63 350 Bore size (mm) With arm Rod flange (including mounting bolt) If one side of the piston is pressurized by supplying air with the clamp arm attached, the piston will move vertically while the clamp arm rotates.
W Double rod K* Non-rotating * available for 150, 200 and 250 bores only ** use single rod designation when ordering XC11 kit Note: XC10 seal kit order 2 single rod kits *** not available with K option How To Order Tie Rods NC1A 150 11 2759 0400 How To Order Cylinder Tube Double Acting Single Rod Applicable Bore Tie Rod Size Bore 150 150 2759 200 200 2760 250 200 2760 325 325 2761 400 325
TYPE1 TYPE1 TYPE1 TYPE1 TYPE1 TYPE1 TYPE1 TYPE1 MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN (mm) 1 2 3 4 5 6 7 8 Stations Rail length L1 110.5 123 148 173 185.5 210.5 223 248 Mounting pitch L2 100 112.5 137.5 162.5 175 200 212.5 237.5 Manifold length L3 L4 82 102 122 142 162 182 202 222 12 12 12.5 12.5 13 13
Standard Strokes Bore size [mm] Standard stroke [mm] Max. manufacturable stroke 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 45 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 56 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 63 25, 50, 75, 100, 125, 150
Table 7.1-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulphate ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70
Conversion cable 25 - (2) Connection with a PC Controller PC 120.3 120.3 mm mm 200 200 mm/s mm/s USB cable (A-miniB type connector) Communication 100 500 100 500 1 1 200 1000 200 1000 2 2 cable 50 200 50 200 3 3 SI When using the LEC-W2, it is necessary to connect a conversion unit (P5062-5) to the communication cable.
Conversion cable 21 No.JXC-OMY0002-A 2 Connection with a PC Controller PC 120.3 120.3 mm mm 200 200 mm/s mm/s Communication cable USB cable (A-miniB type connector) 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 SI When using the LEC-W2, it is necessary to connect a conversion unit (P5062-5) to the communication cable.
Controller USB cable Communication 120.3 120.3 mm mm 200 200 mm/s mm/s (type A to mini-B) cable 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN3 PC (PC is prepared by the user.) 20 - 4.4 CN4: Counter connector (option) Connect the controller to the Multi-counter (CEU5) using the counter cable (LATH3-). Refer to section 6.2 Counter plug wiring (P.24).
ISA2-G ISA2-H Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 2.0 0.05 0.03 Supply pressure Supply pressure 50 kPa 100 kPa 0.04 30 kPa Hysteresis (mm) Hysteresis (mm) 0.02 0.03 100 kPa 0.02 200 kPa 0.01 200 kPa 0.01 0 0 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 0 0.05 0.1 0.15 0.2 0.25 Detection distance (mm) Detection
, 200, 300 (N) 100, 200, 300, 400, 500 15 750 1 axis Operating pressure (MPa) Piston area (mm2) 100, 200, 300, 400, 500, 600 20 Bore size (mm) 1000 0.3 0.2 0.4 0.5 0.6 0.7 100, 200, 300, 400, 500, 600, 800 25 1200 10 15 23 78 31 39 54 46 100, 200, 300, 400, 500, 600, 800, 1000 25 2 axis 15 35 52 176 70 88 123 105 1500 32 20 62 94 314 125 157 219 188 Note) Strokes are manufacturable in 1 mm