AMD AMH Data A: Inlet Air Temperature Data B: Ambient Temperature Data C: Inlet Air Pressure AME Inlet air temperature Ambient temperature Inlet air pressure MPa psi Correction factor F C Correction factor AMF Correction factor IDFB3E to 37E IDFB55E, 75E 1.31 F C 77 90 95 100 104 25 32 35 37.8 40 75 100 110 120 125 150 175 200 232 0.53 0.70 0.76 0.83 0.86 1.03 1.21 1.38 1.60 1.24 0.95 ZFC
(40) AS32l1FG-02-08(S)A 8 13.2 22.7 33 14.2 41 (41) AS32l1FG-02-10(S)A 10 15.9 26.7 37 35.7 15.6 42 (42) AS32l1FG-02-12(S)A 12 18.5 29.7 40 34.5 17 43 (43) AS32l1FG-03-06(S)A 6 10.4 21.8 32.1 36.4 50 48.4 44.5 42.9 1/4 19 16.6 13.3 29 (30) AS32l1FG-03-08(S)A 8 13.2 22.7 33 14.2 AS32l1FG-03-10(S)A 10 15.9 26.7 37 28 15.6 30 (31) AS32l1FG-03-12(S)A 12 18.5 29.7 40 26.8 17 32 (33) AS42l1FG-
Connector entry direction D side U side Electrical entry External pilot supply port Indicator light IP65 compatible U0 U1 U2 U3 U side D0 D1 D2 D3 D side Without cable Cable length 1.5 m Cable length 3 m Cable length 5 m Kit F Kit F U0 U1 U2 D0 D1 D2 1 to 12 stations Cable length 0.6 m Cable length 1.5 m Cable length 3 m Kit L Kit L 1 to 12 stations Type of connection T1 S kit (Serial transmission
P: PTFE F: FKM For VCS30 OR-2380-130P P: PTFE F: FKM For VCS40 OR-2600-180P P: PTFE F: FKM Manifold For VCS20 e OR-1400-178P P: PTFE F: FKM OR-2670-178P r P: PTFE F: FKM Wave washer For VCS30, 40 When the loosened clip is pulled out in direction e using pinchers, etc., the coil can be removed and replaced in direction r.
54 54 66 66 F 30 41 50 50 70 70 P 28 57 73 73 H 22 23 26 25 35 35 E 47 47 D 25 40 53 70 70 90 95 A B 77 115 142 176 176 250 268 J 5.4 6.5 8.5 8.5 11 11 K 8.4 8 10.5 10.5 13 13 C 26 36 38 40 38 41 45 L 40 53 70 70 90 90 M 2.3 2.3 2.3 2.3 3.2 3.2 AL10 AL20 AL30 AL40 AL40-06 AL50 AL60 M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 25 40 53 70 75 90 95 Optional specification
Calculation of applied lateral load The lateral load F equals the total load of the work piece. Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 70 Lateral load F (N) 60 0.4MPa 50 40 2. Confirmation of allowable lateral load From the graph, the allowable lateral load at L=50mm and P=0.4MPa is 18N. 2.
Local Area: (800) 258-9200-www.stevenengineering.com SYJA5 20 1 M5 Body ported SYJA5 40 2 Base mounted Port size Thread type Type of actuation Nil Rc G NPT NPTF Without sub-plate Nil 4 3 2 position double 2 position single 2 1 1/8 With sub-plate 01 F N T JIS Symbol Body ported 3 position closed center 3 position exhaust center 5 3 position pressure center 2 position single 2 position double
Calculation of applied lateral load The lateral load F equals the total load of the work piece. Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 70 Lateral load F (N) 60 0.4MPa 50 40 2. Confirmation of allowable lateral load From the graph, the allowable lateral load at L=50mm and P=0.4MPa is 18N. 2.
4/5 Port Air Operated Valve SYJA3000 Series How to Order Bracket With bracket F Nil Without bracket *Refer to page 1475 for the details of the brackets.
Speed Controller with Indicator AS-FS Series RoHS Numerical indication of knob rotation for flow rate AS-F AS-F Universal reduces flow setting time and setting errors! reduces flow setting time and setting errors!
1] [F] 2 2 2 2 2 () [F 1] OUT1 28 ( ) ON OFF 50% 5% ON OFF [F 2] OUT2 36 ( ) ON OFF 50% 5% OUT1 26 No.LFE*-OMY0008 [F 3] 40 1 [F10] 41 [F20] 45 [F22] 46 OFF [F30] 47 OFF[] [F32] 48 OFF[] [F33] 50 FR0 [F34] 51 OFF [F80] 52 [] [F81] 53 OFF [F82] 54 [*] [F90] 55 OFF [F98] 56 OFF [F99] 57 OFF 30 [F10](41 ) OUT2 (20L/min ) OFF OFF OFF OFF 27 No.LFE
C u t o f f M O D E < 7 0 . 0 C sensor (Ex. : 70.0 C). Function : Sets upper limit of temp. which the internal temp. sensor detects and judges the unit should be shut off. When the temp. set in this item is reached, the alarm [ERR12] arises. L o w T e m p . C u t o f f 9. Low Temp.
0.3 0.4 0.5 0.6 Suction flow (l/min(ANR)) Supply pressure (MPa) ZQ110 Exhaust characteristics ZQ110 Flow characteristics Maximum suction flow (l/min(ANR)) Air consumption (l/min(ANR)) Maximum vacuum pressure (kPa) Maximum vacuum pressure (kPa) Maximum vacuum pressure -80 -80 60 -60 -60 50 40 -40 -40 30 Air consumption 20 -20 -20 10 Maximum suction flow Suction flow (l/min(ANR)) 25 20 15
Roller Lever Adjustable Rod Lever P3.5-40 P3.5-34.
OUT1 [CoL] [] , ON OFF ON OFF [F 1] OUT1 -36No.PF-OMS0001CN-A [F 2] OUT2 OUT2 (29 )(30 ) OUT2()[---] <>OUT2 [F 2] [oUt2][]() OUT2 [---] [oU2] [] [2ot] [] 38 39 40 41 -37No.PF-OMS0001CN-A a.
Ambient Ambient temperatur temperatur Heating capacityW Heating capacityW 1500 e e 1500 40 32 25 20 5 40 32 25 20 5 1000 1000 500 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature Circulating fluid temperature 50Hz 60Hz Fig. 9-6 Heating capacity(HRS060-W-20-(BJM)) HRS Series 9.4 Cooling capacity 9-7 HRX-OM-R005 Chapter 9 Documents 9.6 Pump capacity 9.6.1
20 10 0 100 Suction flow [L/min(ANR)] Air consumption [L/min(ANR)] Vacuum pressure Vacuum pressure [kPa] Vacuum pressure [kPa] 80 60 Suction flow 40 20 Air consumption 0 0 10 20 30 40 Supply pressure [MPa] Suction flow [L/min(ANR)] ZHP-10 ZHP-10 (Supply pressure: 0.35 MPa) 100 90 80 70 60 50 40 30 20 10 0 0 0.1 0.2 0.3 0.4 0.5 0.6 100 90 80 70 60 50 40 30 20 10 0 100 Suction flow [L/min(
Body Ported Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB/CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQZ1121-C6 Courtesy of Steven Engineering,
[F 1] OUT1 23 - [F 2] OUT2 OUT2 ONOFF OUT2 OUT2ON (P_1 H_3OFF)OFF ON(P_1 H_2ON), ON ONOFF H_2H_4 (H_1 H_2 + H_4 ) P_1-70.0 kPaH_1:10.0 kPaH_2:5.0 kPaH_3:0.0 kPaH_4:1.0 kPa OUT2 () OUT1 (V) H_2 24 - <> [F 2] ON OFF OFF ON ON [F 2] OUT2 1 2 2 3ON(H_4)OFF(H_2) 25 - [F 3] <> [F 3] , [F 3] 26 - [F 4] <> [F 4] , [F 4] , (28 -) ,ON/OFF 27 - OUT1 , AP1 OUT1 OUT1 OUT1 A1L