Brown 2 A B-1 Red 1 A A-1 Cable length (L) Orange 6 B B-2 Yellow 5 B A-2 8m *1 8 Green 3 COM-A/COM B-3 10m *1 A Blue 4 COM-B/ A-3 Shield 15m *1 B Cable color Terminal no. Vcc B-4 Brown 12 *1) produced upon receipt of order. 20m *1 C GND A-4 Black 13 A B-5 Red 7 A A-5 Black 6 B B-6 Orange 9 Only Robotic type cable can be B A-6 Black 8 3 selected.
2 A A-A' Piston rod section A' !1 !3 !4 Component Parts Note Description Material No.
35 AFD40-06-A 50 52 25 8.5 12.5 70 2.3 34 Dimension:B of auto-drain and optional bowl assembly Option Semistandard 2 6 8 C 6C J 2J 6J 8J CJ 6CJ W 6W AFD20-A 87.4 87.6 87.6 87.6 91.4 93.9 91.4 91.4 91.4 AFD30-A 117.6 115.1 137.6 121.9 122.1 121.9 142.1 123.6 123.6 AFD40-A 149.6 147.1 169.6 153.9 154.1 153.9 174.1 155.6 155.6 AFD40-06-A 151.6 149.1 171.6 155.9 156.1 155.9 176.1
35 AFM40-06-A 50 52 25 8.5 12.5 70 2.3 34 Dimension:B of auto-drain and optional bowl assembly Option Semistandard 2 6 8 C 6C J 2J 6J 8J CJ 6CJ W 6W AFM20-A 87.4 87.6 87.6 87.6 91.4 93.9 91.4 91.4 91.4 AFM30-A 117.6 115.1 137.6 121.9 122.1 121.9 142.1 123.6 123.6 AFM40-A 149.6 147.1 169.6 153.9 154.1 153.9 174.1 155.6 155.6 AFM40-06-A 151.6 149.1 171.6 155.9 156.1 155.9 176.1
5 2 4 3 2 1 2(B) (A)4 (EA) (A) (P) (B) (EB) (EA)5 1 3(EB) (P) (Drawing shows a closed center type.)
AL-OMQ0006-C PRODUCT NAME LUBRICATOR MODEL / Series / Product Number AL10-M5(-2,3,6,R,Z)-A AL20-(F,N)01(F,N)02(B)(-2,3,6,C,R,Z)-A AL30-(F,N)02(F,N)03(B)(-2,3,6,8,R,3W,Z)-A AL40-(F,N)02(F,N)04(B)(-2,3,6,8,R,3W,Z)-A AL40-(F,N)06(B)(-2,3,6,8,R,3W,Z)-A AL50-(F,N)06(F,N)10(B)(-2,3,6,8,R,3W,Z)-A AL60-(F,N)10(B)(-2,3,6,8,R,3W,Z)-A Contents Page 1. SAFETY INSTRUCTIONS 1-5 2. APPLICATION 6 3.
VVPA4 5 0 04 04 1 Thread type Nil Rc G NPT NPTF VP 5 port Air operated manifold F N T 5 Base size Rc A, B Port size Rc 3 4 6 1 VVPA450 Symbol 04 Port size VVPA460 1 2 3 4 Mixed 1 06 10 M (2) Piping Note 2) In the case of mixed specifications, indicate M and specify port location sparately on a manifold specification sheet.
Power Valve: Economy Valve Series VEX5 Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. Standard Specifications Model VEX5504 06 10 VEX5710 12 VEX5914 20 The conventional valve combination circuit has been condensed into a single valve.
Maintenance detection signal ON OFF Output Requirement for maintenance detected ON OFF Input External switch signal 1, 2 455 IZN10 Series Dimensions 06 07 06 07 Energy saving static neutralization nozzle/IZN10-01 High flow rate nozzle/IZN10-02 20 Note 1) (110) 16 100 5 5 46 A 3.4 18.5 11 6 5 6 A 8 7 (Tap for ground wiring) M3 x 0.5 depth 4 40 25 12 A 93.6 A-A (mm) A Model 01 02 01 02 IZN1006
Rc G NPT C3SL-2(Z)-A Rc G NPT C3SL-23(Z)-A C3SL-2-A C3SL-23-A Appearance and part No. -11- 8 38 Semi-standard symbol Semi-standard: 38 Semi-standard: 8 Piping port thread ty pe Piping port thread ty pe (7) Part No. (7) Part No. Rc Rc C3LL-38-A C3LL-8-A G G NPT C3LL-38(Z)-A NPT C3LL-8(Z)-A Appearance and part No. Note 1) Part No. (7) includes Bowl seal (6). Refer to section [11.
B-1 2 L A A-1 1 B (B-2) 6 1 1.5m B (A-2) 5 COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m (3) Shiel d Vcc (B-4) 12 GND (A-4) 13 A (B-5) 7 A (A-5) 6 S B (B-6) 9 B (A-6) 8 3 (14.2) (2 ) 2 1 (8) (1 ) B1 A1 (14) (18) (17.7) 6 5 (3 ) 2 1 B6 A6 15 16 (11) (30.7) 15.2 [820m] (1) (2) -L A B-1 2 A A-1 1 B (B-2) 6 8 8m* B (A-2) 5 COM-A/COM B-3 3 A 10m* COM-B/ A-3 4 B 15m* (3) Shield
Stations Orifice diameter 1/4 3/8 1/2 Valve type Symbol Type 4 8 10 P P Manifold A A N.C. Stations are counted from station 1 on the left side, with the A (OUT) ports in front. A Non-locking Locking A A (OUT) port
PB B A B A B A N.C. N.O. Double acting Double acting With flow rate adjustment PA PA N.C. B A PB B A Double acting N.C. Double acting With by-pass PA PA N.C. PB B A B A Double acting N.C. Double acting With flow rate adjustment & by-pass PA PA N.C. PB B A B A Double acting N.C.
AN120-M5 AS3001F-06 AN110-01 SY3120-C6 SY3140-01 T0604 x 1 m T0806 x 1 m AS3001F-06 T0604 x 1 m T0806 x 1 m AS3001F-08 AS3001F-06 SY5120-01 SY5140-02 AS3001F-08 AN101-01 AN101-01 T1075 x 1 m T0604 x 1 m T0604 x 1 m T1209 x 1 m T1075 x 1 m AS4001F-10 SY7120-02 SY7140-03 AS3001F-06 AS4001F-10 AS3001F-06 AN110-01 AN200-02 T0604 x 1 m T1075 x 1 m T1209 x 1 m T0604 x 1 m T1075 x 1 m T1209 x 1
(SUP. port) (VAC. port) (EXH. port) ZB D A S 10 ZH 06 06 08 Body Ported ZA Accessories (Standard bracket/Silencer)2 Nozzle size ZX 05 0.5 mm 07 0.7 mm 10 1.0 mm 13 1.3 mm 15 1.5 mm 18 1.8 mm 20 2.0 mm Symbol Standard bracket Silencer Nil N S1 NS1 1 Options S and NS are not available for EXH. port with a screw-in connection. 2 Each accessory is not assembled with the product, but shipped
RE A B Model Recommended Speed Controller REC Model Elbow type Straight type In-line type CX REC20 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 REC25 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 CY REC32 AS2201F-01-06-X214 AS2301F-01-06-X214 AS3001F-08-X214 REC40 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way
Using a regulator on the secondary side When mounting a regulator on the secondary side (A port side), use a residual pressure relief regulator (AR2550 to 4050) or a check type regulator (AR2560 to 6060). With a standard regulator (AR1000 to 6000), the secondary side pressure may not be released when this valve is exhausted. 5.
ANm0m0-KMmm 5.2-4 40dB(A): High Noise Reduction Silencer Series ANA1 A high noice reduction style silencer keeps the noise level inside a plant below 85dB(A).
Symbol 0 A square plug set is normally used for the drain unit.