Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: None,
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket), Calibration Certificate
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: None
Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: EPDM Seal Material
Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: Analog
Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: Analog
Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 3/8, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: None, Made to Order: Analog
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material)
Series: 3000 (SY3000), Port Size: 1 (Standard), Thread Type: T (NPTF)
Series: 5000 (SY5000), Port Size: 1 (Standard), Thread Type: T (NPTF)
Series: 7000 (SY7000), Port Size: 1 (Standard), Thread Type: T (NPTF)
Series: 9000 (SY9000), Port Size: 1 (Standard), Thread Type: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping)
Function: 4 (3 Position Exhaust Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 01 (Base Mounted w/Sub-plate 1/8 Side Piping)
Function: 1 (2 Position Single), Piping: 30 (Body Ported/Common Pilot EXH), Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush)
Function: 2 (2 Position Double), Piping: 20 (Body Ported/Individual Pilot EXH), Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush)
Function: 1 (2 Position Single), Piping: 20 (Body Ported/Individual Pilot EXH), Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush)
Function: 1 (2 Position Single), Piping: 20 (Body Ported/Individual Pilot EXH), Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Thread: N (NPT)
Function: 1 (2 Position Single), Piping: 20 (Body Ported/Individual Pilot EXH), Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Thread: T (NPTF)