SMC Corporation of America
Elite Part Number Search
Search Results "NCGBA40-3000"

Ratio of discharge amount to fresh water (%) 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity (mPa s) mPas Silicone oil Lubricant Vegetable oil Water 60 to 80 1 6080 340 950 1500 3150 9800 Viscosity (mPa s) cp 0 100 1000 10 150 | 2650 45 | 2 3000 4500 Tomato juice Honey Medical barium Wooster source Cutting oil 4500 45 2000 to 3000 8 - 8.

3000 Ambient 40oC 2000 2000 Ambient 45oC 1000 1000 Ambient 45oC 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9.4-1 Cooling capacity(HRS050-A-20-R) 9.5 Heating capacity 2000 2000 Ambient 45oC 1500 1500 Ambient 40oC Ambient 45oC Heating Capacity [W] Heating Capacity [W] Ambient 40oC 1000 1000 Ambient 32oC Ambient 25oC

3000 facility water temperature facility water temperature 2500 2500 2000 2000 25 32 40 25 32 40 1500 1500 1000 1000 500 500 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature Circulating fluid temperature 50Hz 60Hz The cooling capacity will be reduced by 300W when option: T and MT are selected.

25 25 3000 32 32 40 40 2000 2000 1000 1000 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature[] Circulating fluid temperature[] 50Hz 60Hz *The cooling capacity will be reduced by 300W when option: T and MT are selected.

3000 32 32 2000 2000 40 40 1000 1000 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig. 9-4 Cooling capacity(HRS050--20-(BJM)) 9.5 Heating capacity 9.5.1 HRS050-A-20-(BJM) 2000 2000 Ambient Ambient temperature temperature 1500 1500 5 Heating capacity [W] Heating capacity [W] 5 20 20 25 25 1000 32 1000 32 40 40 500 500 0

3000 32 2000 2000 40 40 1000 1000 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature Circulating fluid temperature 60Hz 50Hz Fig. 9-4 Cooling capacity(HRS060--20-(BJM)) 1. 5 1. 5 1. 5 1. 5 1. 5 1. 5 kW kW kW kW kW kW 1 1 1 1 1 1 0. 5 0. 5 0. 5 0. 5 0. 5 0. 5 0 0 0 0 0 0 9.5 Heating capacity 0 2 0 2 0 2 0 1 2 0 1 2 0 1 2 HRS060-A-2050Hz HRS060-A-2050Hz HRS060-A-2050Hz

4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% for breaker capacity) For HRS100-A/W-46 HRS150-A/W-46 3.3 Installation HRS Series 3-14 HRX-OM-S004 Chapter 3 Transport and Setting Up Preparation for operation 1.

[oC] (2) Cooling capacity correction coefficient Less than 1000 m 45 1.00 1000 m or more Less than 1500 m 42 0.85 1500 m or more Less than 2000 m 38 0.80 2000 m or more Less than 2500 m 35 0.75 2500 m or more Less than 3000 m 32 0.70 3.2.2 Location Install the product only in a location that may be subject to any of the conditions in "3.2.1 Environment".

2500 Cooling capacity W 2000 Fluid: Water 1500 1000 Fluid: Fluorinert FC-77 500 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig. 6-5 Cooling capacity of HEC012 2) Heating capacity Radiating Water Temp.20 oC Radiating Water flowrate10L/min 3000 2500 Heating capacity W Fluid: Water 2000 1500 1000 Fluid: Fluorinert FC-77 500 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig

. -3No.LEY*-OMZ0010 1Rod type / LEY Series 1.1 Specification Model LEY 25E-X8 LEY 32E-X8 LEY 40E-X8 (3000 [mm/s2]) 20 40 60 30 45 60 50 60 80 Horizontal Work load [kg] Note1) (2000 [mm/s2]) 30 55 70 40 60 80 60 70 90 Vertical (3000 [mm/s2]) 7 15 29 10 21 42 12 26 52 Pushing force [N] Note2) Note 3) Note 4) 63 to 122 126 to 238 232 to 452 80 to 189 156 to 370 296 to 707 132 to 283 266 to 553

6 mm 1 Brown: 24 VDC (For solenoid valve) Nominal cross section AWG22 2 White : 0 V (For solenoid valve) Wire diameter (Including insulator) 1.5 mm 3 Blue : 24 VDC (For control) Min. bending radius (Fixed) 40 mm 4 Black : 0 V (For control) 5 Gray : Not connected -30No.EX-OMN0011-F (2) Cable with power supply connector (SPEEDCON) Part number: PCA-140180 4 Cable length (L) 4 1500 [mm] 5 3000

6 mm 1 Brown: 24 VDC (For solenoid valve) Nominal cross section AWG22 2 White : 0 V (For solenoid valve) Wire diameter (Including insulator) 1.5 mm 3 Blue : 24 VDC (For control) Min. bending radius (Fixed) 40 mm 4 Black : 0 V (For control) 5 Gray : Not connected -36No.EX-OMO0030-E (2) Cable with power supply connector (SPEEDCON) Part number: PCA-140180 4 Cable length (L) 4 1500 [mm] 5 3000

6 mm 1 Brown: 24 VDC (For solenoid valve) Nominal cross section AWG22 2 White : 0 V (For solenoid valve) Wire diameter (Including insulator) 1.5 mm 3 Blue : 24 VDC (For control) Min. bending radius (Fixed) 40 mm 4 Black : 0 V (For control) 5 Gray : Not connected -36No.EX-OMN0009-G (2) Cable with power supply connector (SPEEDCON) Part number: PCA-140180 4 Cable length (L) 4 1500 [mm] 5 3000

Applicable solenoid valve series Number Valve series Enclosure Mounting Valve interface SV1000/2000/3000/4000 VQ1000/2000 SY3000/5000/7000 IP20 EX120-SMJ1 Direct Plug-in EX121-SMJ1 SY3000/5000 Flat ribbon cable DIN rail EX122-SMJ1 SY3000/5000 EX124U/D-SMJ1 VQ2000/4000/5000 IP65 Plug-in SY3000/5000/7000 SV1000/2000/3000 VQC1000/2000/4000 Direct EX126D-SMJ1 IP67 -31No.EX-OMB0014-H Dimensions

SV1000/2000/3000/4000 SY3000/5000 VQC1000/2000/4000 S0700 -31No.EX##-OMO0019 Dimensions 1. SI unit for SV series valves (EX500-S001) 2.

. *5 Only for the NPT thread -19- How to Order of Pilot Valve Assembly AV 2 0 1 G B A Applicable size Symbol Description AV AV AV AV 2000 3000 4000 5000 Body size 2 AV2000-A, AV3000-A 4 AV4000-A, AV5000-A 1 AC100V 2 AC200V AC 3 AC110V [AC115V] *1 (50/60Hz) a d Rated coil 4 AC220V [AC230V] *1 voltage DC 5 DC24V 6 DC12V G GrommetLead wire length: 300mm D Type DDIN terminal/With connector

Fig. 8.4-4 Cooling capacity(HRSE018-A-20/23) 8.4.5 HRSE024-A-20/23-(T) Ambient 3000 3000 Ambient Temperature Temperature 2500 2500 25 35 40 25 35 40 Cooling capacity[W] Cooling capacity[W] 2000 2000 1500 1500 1000 1000 500 500 0 0 0 10 20 30 40 0 10 20 30 40 Circurating fluid temperature[] Circurating fluid temperature[] 50Hz 60Hz The cooling capacity will be reduced by 100W when option:

LEMB / LEMC LEMH / LEMHT Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] 0 48 250 48 250 1 75 500 75 500 2 100 1000 100 1000 3 150 1500 150 1500 4 200 2000 200 2000 5 250 2500 300 2500 6 300 3000 400 3000 7 350 4000 500 4000 8 400 5000 600 5000 9 450 6000 800 6000 10 500 7500 1000 7500 11 600 10 1200 10 12 700 12500 1400 12500 13 800 15000 1600 15000 14 900 17500 1800

) MRP (Media Redundancy Protocol) function supported (10) Maintenance alarm supported for the Fiber-optic cables(EX245-SPN1) (11) Integrated diagnostic and protection function (12) Maximum loop through current between power connectors is 10A (13) Galvanically isolated all power supplies (14) Free module configuration Corresponding solenoid valve manifolds SY3000/5000/7000 SV1000/2000/3000

Not guaranteed values. -30 -20 -10 0 0 1000 2000 3000 4000 5000 6000 Piping length [mm] mm Fig. A. Vacuum pressure for piping (ZK215) Tube TU0805 or T0806 Tube TU1065 or T1075 Nipple KQ2N08-99 Straight type of different diameter KQ2H08-10A Fig. B Example of piping -74No. ZK2-OM01301 In addition, the exhaust port should not be blocked or pressurized.