When the upper limit of the scale is set to 5000, and the lower limit of the scale is set to 1000, the result will be as follows. 1000 1 V is input 2000 2 V is input 3000 3 V is input 4000 4 V is input 5000 5 V is input 3. The resolution from 1 to 5 V is 1/1000 based on the calculation (5 V 1 V) / (5000 1000) = 1/1000.
Parameter Initial value Initial value Selection range (value) 2 (mm) Value/Range Setpoint 1 (SP1) 250 12.5 mm D-MP025 0 to 500 Setpoint 2 (SP2) 230 11.5 mm Measuring range 0 to 500 25 mm Setpoint 1 (SP1) 500 25 mm D-MP050 0 to 1000 Setpoint 2 (SP2) 480 24 mm Measuring range 0 to 1000 50 mm Setpoint 1 (SP1) 1000 50 mm D-MP100 0 to 2000 Setpoint 2 (SP2) 980 49 mm Measuring range 0 to 2000 100
17500 15 1000 20 2000 20 48 No.JXC-OMU0030-A 11.
L/min Pressure loss PFMB7501 (500 L/min) PFMB7102 (1000 L/min) PFMB7202 (2000 L/min) -69No.PF-OMS0002-B Straight inlet piping length and accuracy (reference value) The smaller the piping size, the more the product is affected by the straight piping length.
Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz, when the actuator was tested in both an axial direction and a perpendicular direction to the lead screw. (The test was performed with the actuator in the initial state.) Note 6) Only when the motor option, "with lock", is selected.
3000 4000 Current (% to the capacity of the main breaker of this product) Figure 3-7 Breaker operating characteristics curve HRZ010-WS HRZ010-W1S HRZ010-W2S 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min MAX 30s 20s 10s 5s MIN 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600 700 1000 1500 2000 3000 4000 5000 7000 1 0 Current (% to the capacity of the main breaker
ZK2-OM00201 (7) Connector assembly ZK2 LV W K A Valve type: J Valve type: K, R Applicable valve type Lead wire length Nil 300 mm Valve type K, R 6 600 mm W (With supply valve and release valve) 10 1000 mm 20 2000 mm S Valve type J (Supply valve only) 30 3000 mm (8) One-touch fitting assembly (Purchasing order is available in units of 10 pieces.)
Allowable Kinetic Energy Mounting Brackets/Part No. 2000 Bore size [mm] 32 40 50 63 80 100 125 125 1000 100 Axial foot Note 1) MB-L03 MB-L04 MB-L05 MB-L06 MB-L08 MB-L10 MB-L12 80 500 Rod/Head flange MB-F03 MB-F04 MB-F05 MB-F06 MB-F08 MB-F10 MB-F12 300 400 63 Single clevis MB-C03 MB-C04 MB-C05 MB-C06 MB-C08 MB-C10 MB-C12 50 Double clevis MB-D03 MB-D04 MB-D05 MB-D06 MB-D08 MB-D10 MB-D12 200
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states to the axis and right angle direction of the main valve and armature. (Value in the initial stage.) Note 2) At the rated voltage.
0.2 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 Minimum operating pressure (MPa) 0.16 0.16 40 1500 2000 0.14 0.15 0.12 0.15 Note 1) Contact SMC if the maximum stroke will be exceeded.
Screw lead LC1-1(Either T-nuts or T-brackets for mounting) LC1-1-1000 (Controller connector) LC1-1-2000 (Controller connector) (Refer to page 85.) F H L 6mm 10mm 20mm Note) The following options are necessary for operating and setting the controller.
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2000 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing September, 2000 D-SMC.L.A. P-80 (N)
Note 2) Model MGPL (ball bushing) cannot be used as a stopper. 1 5 20 30 40 50 10 Transfer speed: (m/min) Bore Sizes 32 to 100/MGPM32 to 100 (Slide bearing) MGPM32 to 100 (Slide bearing) m m 2000 l: Approx. 50mm l: Approx. 50mm 100 1000 80 Weight of transfered object: m (kg) 63 500 400 50 300 40 200 When selecting a model with a longer l dimension, be sure to choose a bore size which
2000 2000 *When the required stroke is longer than the standard stroke , refer to the specifications for Made to Order q (p.5.4-79) longer stroke styles.
(Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve when pilot signal is ON and OFF.
(Value in the initial stage) Vibration resistance: No malfunction from test with 45 to 2000 Hz one sweep, to axis and right angle direction of main valve, each one time when pilot signal ON and OFF. (Value in the initial stage) Note 4) As per JIS C 0920 Manifold possible. When requiring bottom piping, please specify it.
(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.