SMC Corporation of America
Elite Part Number Search
Search Results "MDWBD50-500-V"

For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.

G T L S M kit (Flat ribbon cable with terminal block) kit (Terminal box) kit (Lead wire) kit (Serial transmission unit) kit (Multi-connector kit) Number of pins: 20 (VQ2000 only) 2-4-113 Valve Specifications Sonic conductance Type of actuation Voltage Electrical entry Manual override C [dm3/(sbar)] 4/2 5/3 (A/B R1/R2) 12 V 24 V DC 100 V 110 V AC 200 V 220 V AC 50/60 Hz 50/60 Hz Push type

Designation Content 1 SV24 V (PWR(V)) +24 V for valves 2 SV0 V (PWR(V)) 0 V for valves 3 SI24 V (PWR) +24 V for logic/sensors 4 SI0 V (PWR) 0 V for logic/sensors Fig. 2-4 Pin allocation of M12 4 pin plug A-coded connector Power-supply line for valves and power-supply line for logic/sensors operation are isolated. Be sure to supply power respectively.

600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500 700 900 10 500 700 900 10 700 1,000 Flow rate Q l/min (ANR) How to read the graph The sonic range pressure to generate a flow rate of 500 l/min (ANR) is P1 0.14 MPa for a 6 orifice (VX2 4), and P1 0.3 MPa for a 4.5 orifice (VX23). 3 2 For Saturated Steam [663] (179) Upstream pressure of valve P1 1.0 MPa

Operating: 0 to 50C, Stored: 25 to 85C (with no condensation and freezing) Operating temperature range 1000 VAC for 1 min. between external terminal and case Voltage resistance 50M or more (500 VDC Mega) between external terminal and case Insulation resistance 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration in each X, Y, Z direction for 2 hrs., whichever is smaller.

(The SI unit type is provided for use in Japan.) 01 02 03 04 06 10 1/8 V 1/4 V V V 3/8 V V 1/2 V 3/4 V V 1 V 17 Series AC Spacers and Brackets Accessories Spacer (X) D Center of F.R.L. body C 1 X-X B X RELEASE 2 Y200 Y400 X Applicable model A 6 3 4 5 5 B 27 35.5 47 57 61 C 15 18.5 26 31 33 D 33 48 59 65 70 Model Y100 Y200 Y300 Y400 Y500 Seal AC10, AC10A, AC10B AC20 AC25, AC30 AC40 AC40-

function: 20, 100, 500, 1000 or 2000 ms selected) Short circuit protection Provided Repeatability 0.2%F.S. 1 digit Hysteresis Hysteresis mode 0 to variable 1 Window comparator mode Voltage output 2 Output Voltage (rated pressure range) 1 to 5 V 2.5%F.S. 0.6 to 5 V 2.5%F.S.

Designation Content 1 L+ +24 V for logic/input 2 P24 +24 V for output 3 L0 V for logic/input 4 C/Q IO-Link communication data 5 N24 0 V for output Fig 2-1. Pin allocation of M12 5 pins plug A-coded connector The power supply for logic/input and the power supply for output are isolated. 2.2.

$ $ G59 G5P K59 G39 K39 G59W G5PW K59W G5BA 3-wire (NPN) IC circuit 5 V, 12 V 24 V 3-wire (PNP) Grommet 12 V 2-wire 100 V, 200 V Solid state auto switch Reed auto switch 3-wire (NPN) 2-wire Terminal conduit 12 V 3-wire (NPN) IC circuit Yes Relay, PLC 5 V, 12 V Diagnostic indication (2-color indication) 3-wire (PNP) 12 V 2-wire 24 V Grommet 3-wire (NPN) 3-wire (PNP) 5 V, 12 V M9PA

12 V 3-wire (PNP) 24 V Grommet 12 V 2-wire 100 V, 200 V Reed auto switch Solid state auto switch 3-wire (NPN) Terminal conduit 12 V 2-wire 3-wire (NPN) Relay, PLC IC circuit Yes 5 V, 12 V Diagnostic indication (2-color indication) 3-wire (PNP) 2-wire 24 V 12 V Grommet 3-wire (NPN) 5 V, 12 V 3-wire (PNP) Water resistant (2-color indication) 2-wire 12 V 4-wire (NPN) 5 V, 12 V IC circuit

Lead wire length Model 3m (~9ft) 0.5m (~1 1/2ft) D-Y7PW(V)/3 wire PNP output 53 (1.9) 10 (0.35) D-Y7N, Y7P 50 (1.8) 9 (0.3) D-Y7B DC (+) Brown [Red] Dimensions (mm) Main switch circuit 1in = 25.4mm OUT Black [White] D-Y7W Mounting screw M2.5 x 4 l Slotted-head set screw 2.5 DC () Blue [Black] Indicator light 3.4 SMC 6.2 D-Y7BW(V)/2 wire 29 (500) (3000) (5000) OUT (+) Brown [Red] 5 l Operating

Apparent power (VA) Volt-ampere is the product of voltage (V) and current (A). Power dissipation (W): For AC , W = V/A cos. For DC, W = V/A. (Note) cos shows power factor. cos = 0.6 2. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. 3.

Normally closed Normally open Double acting VNA01 VNA02 VNA03 Coil rated voltage (V) AC (50/60 Hz) 100 V, 200 V, Other voltage (Option) 24 V, Other voltage (Option) 15% to +10% of rated voltage 35C or less (When rated voltage is applied.) 5.6 VA (50 Hz), 5.0 VA (60 Hz) 12 VA (50 Hz), 10.5 VA (60 Hz) 3.4 VA (50 Hz), 2.3 VA (60 Hz) 7.5 VA (50 Hz), 6 VA (60 Hz) DC 12 (P1) 12 (P1) 10 (P2) Allowable

100 V, 200 V 12 V 2-wire 24 V CJ1 No 200 V or less Relay, PLC Yes Connector 24 V or less 5 V, 12 V No IC circuit CJP Grommet Diagnostic indication (2-color indication) Yes 3-wire (NPN) 3-wire (PNP) IC circuit CJ2 5 V, 12 V Grommet 12 V 2-wire CM2 Connector 3-wire (NPN) IC circuit Relay, PLC 5 V, 12 V Diagnostic indication (2-color indication) Yes 3-wire (PNP) 24 V CG1 Courtesy of Steven

Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 50 63 80 100 125 140 160 180 200 250 300 Average speed (mm/s) Series 1000 1100 Perpendicular, upward actuation 900 Horizontal actuation 800 700 600 500 400 300 200 100 VK VQ7-8-FG-S-A03 VQ7-8-FG-S-RA03 VZ VF 0 1000 1100 VFR 900 800 700 600 500 400 300 200

Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 50 63 80 100 125 140 160 180 200 250 300 Average speed (mm/s) Series 1000 1100 Perpendicular, upward actuation 900 Horizontal actuation 800 700 600 500 400 300 200 100 VK VQ7-8-FG-S-A03 VQ7-8-FG-S-RA03 VZ VF 0 1000 1100 VFR 900 800 700 600 500 400 300 200

Note 13) When option Y is selected, V for (4) exhaust sealing valve cannot be selected. -10No. ZKJ-OM00201-D 2.

Applicable cable of the power supply connector Cable cross section Single wire, stranded wire 0.2 mm2 to 2.5 mm2/AWG24 to 12 Power supply connector for solenoid valve Terminal Wire colour Connection 24 V For solenoid valve +24 V 0 V For solenoid valve 0 V Note Wiring should be carried out with the power supply turned off.

Description Function 1 SV24 V +24 V for solenoid valve. 2 SV0 V 0 V for solenoid valve 3 SW24 V +24 V for SI unit and Input Block 4 SW0 V 0 V for SI unit and Input Block 5 FE Ground -13No.EX-OME0014-F Maintenance Addition of Input Block Remove screws from End Plate. Mount attached tie rod. Connect additional Input Block.

24 V DC 100 V 110 V AC 200 V 220 V AC 50/60 Hz 50/60 Hz 4/2 5/3 (A/B R1/R2) 3 position Closed center Double Single Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal VQ130 0.73 0.84 Plug lead Cassette Plug-in Series VQ1000 Latching Latching Latching Latching Latching VQ131 1.0 0.84 P. 2-4-10 P. 2-4-8 VQ040 0.50 0.36 Series