(1) LECSS2-TAC200V240V (4) (4) RA1 ON OFF RA1 MC MC SK MCCB CNP1 MC (7) MC (6) (11) (10) L1 CNP3 (6) AC 200 V 240 V U U L2 AC200240V V V L3 M W NW P3 (1) (10) (1) (9) PE P4 CNP2 P+ (2) C (2) (11) (3) (10) (3) D CN2 L11 L21 (7) (8) CN3 CN3 DC 24 V ( 12) DC24V (11) (5) 2 EM2 DOCOM (5)2 (5) (5) (4) RA1 ALM (4) DICOM DC 24 V ( 12) DC24V (11) (8) CN8 (9) () () 1. P3P4() 2.
O-ring MY1B25-PS MY1B32-PS MY1B40-PS Note) For the replacement procedure of replacement parts/seals, refer to the Operation Manual. 1192 MY1B Series Mechanically Jointed Rodless Cylinder Basic Type Standard/Centralized Piping Type 25, 32, 40 MY1B25 /32 /40 Z Stroke (LL) L 2 x 2 x B counterbore depth C LD through-hole 4 x MM depth M P(MY1BG) (Hexagon socket head taper plug) PA YW PP QQ RR QW NW
SV1000 SV2000 SV3000 0 NW QW 1 2 3 P, E port position Input block Supply/Exhaust block assembly specification Input block type Without input block M12: 2 inputs M12: 4 inputs M8: 4 inputs (3 pins) A, B port size For mixed mounting, indicate the port size, such as C3 or C4, instead of a "" in the a section of the station table.
Magnet: Built-in, Mounting: Double Clevis, Bore: 16mm, Stroke: 200mm, Head Cover: Perpendicular to Axis, Pivot Bracket: Pivot Bracket not Assembled, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: C80C, Lead
Magnet: D (Built-in Magnet), Mounting: D (Clevis), Type: N (Rubber Bumper), Bore: 20mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 200mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: N (Pivot Bracket not Assembled), Rod End Bracket: W (Double Knuckle Joint), Auto Switch: M9PA--Solid State, Water Resist., 3 Wire PNP
Magnet: D (Built-in), Series: J2, Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 200mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: N (Pivot Bracket not Assembled), Rod End Bracket: W (Double Knuckle Joint), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No
Magnet: Built-in Magnet, Mounting: Clevis, Type: Rubber Bumper, Bore: 20mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 200mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: Pivot Bracket not Assembled, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: C80C, Lead
Valve Type: XYC (In-line Type, Double Acting, Bellows Seal), Flange Size: 80, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: 1, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: Z (5m), Number: A [2 pcs (Valve Open/Closed)]
Flange Size: 40, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)
Valve Type: XLFV (Normally Closed, O-ring Seal), Flange Size: 50, Flange Type: KF (NW), Valve Direction: F (w/Indicator, Left Flange Surface), Version: 2 (Refresh), Auto Switch: M9// (w/o Auto Switch w/Built-in Magnet), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: G [Grommet (Lead Wire Length 300mm)], Surge Suppressor: S (w/
Valve Type: XYA (In-line Type, Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Port Direction: A (w/Indicator, Flange Side; w/Indicator, Rear Flange Surface), Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: , Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: L (3m), Number: A [2 pcs (Valve Open/Closed)]
Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 40, Motor Mounting Position: In-line, Motor Type: NW (Mounting Type W), Lead Screw: B (LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm), Stroke: 150mm
Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: B (1pc, Valve Open)
Flange Size: 50, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: Z (5m), Number: A (2pcs, Valve Open/Closed)
Flange Size: 80, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: Z (5m), Number: A (2pcs, Valve Open/Closed)
Valve Type: XLD (Smooth Exhaust, Normally Closed, Bellows, O-ring Seal), Flange Size: 80, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed)
Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Valve Direction: F (w/Indicator, Left Flange Surface), Version: 2, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 4 (220 VAC, 50/60 Hz), Electrical Entry: G [Grommet (Lead Wire Length 300mm)]
Accuracy: Basic Type, Size: 63, Motor Mounting Position: Top Mounting, Motor Type: NW (Mounting Type W), Lead Screw: L (LEY63, 2.86], Stroke: 150mm, Dust/Drip Proof: P (IP65, Dust/Drip Proof Specification w/Vent Hole Tap), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: D (Double Clevis)