Replacement Parts: Seal Kit 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit no. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.

100 200 300 400 500 100 200 300 400 500 Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K. NO NO YES Is it possible for cable of stroke reading cylinder to be wired separately from the power line? Is there any influence of noise? YES NO YES NO Can the system be operated below 14.5 mT? Do not use it since it will result in a miscount.

To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.

Refrigerant Air connection 300 2.2 IDU3D 350 Series IDU High inlet air temperature type Rated temperature of 50 to 60C Rc 3/8 60C 430 3.7 IDU4D 500 Small Medium Small Medium Large R134a 1 to 4 R 1/2 640 5.5 IDU6D 750 55C R 3/4 Air cooled Air cooled 850 7.5 IDU8D 1000 IDU11D R134a 1300 11 R 3/4 1500 IDU11C 1300 55C 2400 IDU15C 15 2050 R 1 3700 IDU22C/22C1 22 3150 R22 5 to 8 6100 IDU37C/37C1

oscillator Oscillator Optical system CH1 Oscillator CH1 CH2 Cooling capacity [kW] Total 5, 9.5 Temperature stability [C] 0.1 0.5 Set temperature range [C] 15 to 25 CH1+0 to 15 Footprint reduced by 21% Space saving Dual thermo-chiller 1 unit Thermo-chiller 2 units Optical system Optical system Oscillator Oscillator HRLE090 HRS012 HRS090 + Reduced by 0.13 m2 + 0.43 m2 0.37 m2 0.19 m2 965 mm 970 mm 500

fluid temperature [C] Circulating fluid temperature [C] HRSE018-A-20/23-(T) [50 Hz] [60 Hz] 2000 2000 Ambient temperature Ambient temperature 25C Cooling capacity [W] Cooling capacity [W] 25C 1500 1500 35C 1000 1000 35C 500 500 40C 40C 0 0 0 10 20 30 40 0 10 20 30 40 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSE024-A-20/23-(T) [50 Hz] [60 Hz] 3000 3000 Ambient

Air Flow Max. flow line Pressure drop (MPa) Max. air flow rate (m3/min (ANR)) Air flow rate (l /min (ANR)) Model Selection Select the model in accordance with the following procedure taking the inlet pressure and max. air flow into consideration. (Example) Inlet pressure: 0.6 MPa Max. air flow capacity: 5 m3/min (ANR) 1.

Max. air flow rate (m3/min (ANR)) JIS Symbol P . 14-20-55 Inlet pressure (MPa) Caution Be sure to read before handling.

0.5 ~0.6 Nm + G 1/2 M3 0.5 ~0.6 Nm M3 0.5 ~0.6 Nm A-A () 1) 2) 3) 30 1) 2) 1 0.1MPa 5 VN-OMP0002 Series Series Series Series 1 DC AC VT307 VNA ( ) (JIS B2301)(JIS B 2302) VNA (JIS B 6349) VNA 1 ISO VG32 VNA ( JIS K 6439) VNA VNA VNA VNA AS AS AS AS VNA AS 10A 111 420-03 3/8 B(9.5) 12 12 12 12(P1) (P1) (P1) (P1) 10(P2) 10(P2) 10(P2) 10(P2) 12(P1)10(P2) 15A 211 420-04 1/2 B

Compressed air 1.0MPa Fluid Max. operating pressure Min. operating pressure (1) 0.05MPa 1.5MPa Proof pressure Ambient and fluid temperature Filtration rating 5 to 60C 0.01m(95% particle size collection) Oil mist removal rate Max.0.1mg/m3 (ANR) (2) (At saturation of element oil, less than 0.01mg/m3(ANR){0.008ppm}) 2 years or when pressure drop reaches 0.1MPa Element life Note 1) With N.O.auto

Auto Switch Mounting Direct mount Rail mount Watchmakers screw driver Auto switch mounting screw (M3 x 0.5 x 10l) Set screw Auto switch spacer Auto switch D-A9 D-F9 Auto switch mounting nut When tightening the mounting screw, use a watchmakers screw driver with a handle about 5 to 6 mm in diameter. Tighten with a torque of 0.10 to 0.20 Nm.

1) 3 A L 3)Assy R 1) V PV PS 1 1) V V (2)PV (3)PD PS PV PD PS PV PD L B C R B C 8 - No.ZQ-OM01401-B 2. 2.1 () (PE) (2 ) (P) (V) (PS) (PV) V 9 - No.ZQ-OM01401-B (PE) (2 ) (P) (2 ) (4 ) (PV) PS 1 PD PD 2 EXH 2 10 - No.ZQ-OM01401-B 3. 3.1 3.1.1 () 1) (2x3.2) 2) (0.54~0.66Nm) 2 3.1.2 () 1) (ZQ1-BK1-A) (2x 3.2) (4x3.2) 2)0.54~0.66Nm 4 3.1.3 1) () PD M3

No.4 No.3 125 kbps 0 0 1 0 250 kbps Communication speed 0 1 500 kbps Caution 1 1 After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly. Safety cannot be assured in the case of unexpected malfunction.

Rated Flow Range: 2 (2.5 to 100 L/min), Output Specifications: K (OUT: Analog 4 to 20 mA; Remote Type Sensor Unit), Port Size: 6 (3/4; Applicable to LFE2), Thread: Rc, Option: 2 (Lead Wire w/M12 Connector; Bracket; L/min Unit Specification), Insulation Type: None, Piping Port is connected to Negative Ground of the Power Supply), Piping Connection: X8 (Stainless Steel 304)

Rated Flow Range: 3 (5 to 200 L/min), Output Specifications: K (OUT: Analog 4 to 20 mA; Remote Type Sensor Unit), Port Size: 8 (1; Applicable to LFE3), Thread: N (NPT), Option: Lead Wire w/M12 Connector; L/min Unit Specification, Insulation Type: None, Piping Port is connected to Negative Ground of the Power Supply), Piping Connection: X8 (Stainless Steel 304)

Rated Flow Range: 1 (0.5 to 20 L/min), Output Specifications: J (OUT: Analog 1 to 5 V; Remote Type Sensor Unit), Port Size: 4 (1/2; Applicable to LFE1), Thread: Rc, Option: 2 (Lead Wire w/M12 Connector; Bracket; L/min Unit Specification), Insulation Type: None, Piping Port is connected to Negative Ground of the Power Supply), Piping Connection: X8 (Stainless Steel 304)

Rated Flow Range: 3 (5 to 200 L/min), Output Specifications: K (OUT: Analog 4 to 20 mA; Remote Type Sensor Unit), Port Size: 8 (1; Applicable to LFE3), Thread: N (NPT), Option: 2 (Lead Wire w/M12 Connector; Bracket; L/min Unit Specification), Insulation Type: Z (Piping Port is Insulated with the Power Supply), Piping Connection: X8 (Stainless Steel 304)

Connection, IN OUT: 0 (Rc), Port Size: 02 (Rc, NPT, TSJ, UOJ; 1/4), Made to Order: X8 (Aluminum Case)

Piping connections come in C37 brass as standard, while the -X8 option offers 304 stainless steel.  LFE is IP65 rated, and CE and RoHS compliant. Flow ranges (lpm): 0.5-20, 2.5-100, 5-200; Port Sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1 (flow range dependent); Temperature rating: 0-85°C; Output options: 1-5v, 4-20mA; Accuracy: ±4% F.S.; Repeatability: ±2% F.S.

The X8 option is a dust-proof and water-jet-proof specification equivalent to IP67.  This spec is achieved with the addition of several unique features above the standard LEY.  The motor is sealed within an aluminum cover, fitted with M-type metal cable connectors.  The rod passes through a scraper and employs a lubrication retainer to prevent oil film washout.