Function: 3 (3 Position Closed Center), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 06 (Sub-plate Plug-in
Function: 6 (3 Position Perfect), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 06 (Sub-plate Plug-in Terminal
Function: 2 (2 Position Double), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: C (Locking Knob Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 06 (Sub-plate Plug-in Terminal 3/4,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 06 (3/4), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))
Flow Range: 11 (10~100 l/min), Thread: Rc, Port Size: 06 (3/4), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))
Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 06 (3/4), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 6 (12VDC), Lead Wire: G (Grommet)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: P (Stainless Steel Body & Shading Coil, EPR Seal, Class H Coil), Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: G (Grommet)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 4 (220VAC 50/60HZ), Lead Wire: G (Grommet)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: G (Grommet)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 6 (12VDC), Lead Wire: C (Conduit)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: B (Brass or BC6, Copper Body & Shading Coil, EPR Seal, Class B Coil), Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 6 (12VDC), Lead Wire: C (Conduit)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: C (Brass or BC6, Copper Body & Shading Coil, PTFE Seal, Class B Coil), Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: D (BC6, Copper Body & Shading Coil, FPM Seal, Class H Coil), Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: C (Conduit)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: D (BC6, Copper Body & Shading Coil, FPM Seal, Class H Coil), Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: G (Grommet)