Do not indicate suffix N for no lead wire on D-A3A/A44A/G39A/K39A models. 100 V Reed switch Solid state switch Relay, PLC 100 V, 200 V Connector 12 V Yes 2-wire 24 V PLC Terminal conduit 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector IC circuit 3-wire (NPN) 2-wire
Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure (P2) MPa 0.8 Subsonic 0.9 0.6 Critical pressure 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 VXK211l 2 50 100 150 200 250 300 350 VXK2l2l 3 100 200 300 400 500 600 VXK2l3l 4.5 200 400 600 800 1,000 1,200 VXK2 4l 3 2 6 500 1,000 1,250 3 2 VXK2 5l 8 500 700 Flow rate Q l/min (ANR) How to read the graph The sonic range pressure
200 300 300 0.4 MPa 0.4 MPa 150 150 0.3 MPa 0.3 MPa 200 200 0.3 MPa 0.3 MPa 100 100 0.2 MPa 0.2 MPa 0.2 MPa 0.2 MPa 100 100 50 50 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MPa 50 100 150 200 0 0 50 100 150 200 0 40 80 120 160 200 0 40 80 120 160 200 Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) 476 Parallel Style Air Gripper: Wide Type Series MHL2 Model Selection
degrees 3 turns 200 degrees 3 turns 200 degrees 200 degrees 17 mA or less (When 24 VDC is ON) 25 mA or less (When 24 VDC is ON) 17 mA or less (When 24 VDC is ON) Current consumption 0.2 MPa Max. operating pressure Note 1) When using an ejector, there is no problem if pressure of 0.5 MPa is applied for 1 second or less.
300 0 100 200 300 100 200 300 Load (N) Load (N) Load (N) 25 25 25 Lr = 200 mm 0.08 MXQ25-150 MXQ25-150 MXQ25-150 MXQ25-10 MXQ25-10 MXQ25-20 MXQ25-20 MXQ25-30 MXQ25-30 MXQ25-40 MXQ25-40 MXQ25-100 MXQ25-125 MXQ25-150 MXQ25-50 MXQ25-75 MXQ25-10 MXQ25-20 MXQ25-30 MXQ25-40 MXQ25-50 MXQ25-50 MXQ25-75 MXQ25-75 0.12 0.10 MXQ25-75 MXQ25-75 MXQ25-75 MXQ25-40 MXQ25-40 MXQ25-40 Table displacement amount
120 250 W = 300 LAT3m-30 4 200 150 200 150 W = 0 W = 100 W = 200 200 150 300 100 W = 0 W = 100 W = 200 3 300 100 600 50 600 50 2 0 0 0 5 10 15 20 25 30 Stroke(Positioning distance) St [mm] 0 5 10 15 20 25 30 Stroke(Positioning distance) St [mm] 1 Operating condition Model: LAT3F-m Mounting orientation: Horizontal/Vertical Step data input version: Takt time entry method (Triangular drive)
Nil 6 50, 100, 150, 200 1 pc.
Rating symbol DC 24 VS V100-61-5-05 24 VDC DC 12 VS V100-61-5-06 12 VDC 100/110 VS V100-61-4-01 100 VAC 200/220 VS V100-61-4-02 200 VAC 100/110 VS V100-61-4-01 110 VAC 200/220 VS V100-61-4-02 220 VAC 240 VS V100-61-4-07 240 VAC With Light/Surge Voltage Suppressor Rated voltage Part no.
, 250, 300, 350 400, 450, 500 15 1000 Note 2) 20 1500 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25, 32 3000 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 3000 Note 1) Contact P/A if the maximum stroke will be exceeded.
0.03 mm 0.30 0.03 0.15 0.20 0.02 0.10 0.01 mm 0.10 0.01 0.05 0.05 mm 0.02 mm 0 0 0 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Supply pressure [kPa] 75 100 125 150 175 200 225 Piping length: 5 m Piping length: 5 m Piping length: 5 m Reference pressure 0.06 Reference pressure 0.30 Reference pressure 0.60 The distance of switch ON [mm]
/Port exhaust) Suction flow rate (Branch/Port exhaust) Vacuum pressure [kPa] Vacuum pressure [kPa] 600 600 Suction flow rate (Silencer exhaust) Suction flow rate (Silencer exhaust) 500 500 400 400 Air consumption 300 300 Air consumption 200 200 100 100 0 0 Supply pressure [MPa] Supply pressure [MPa] Flow Rate Characteristics (Representative value) ZL3H (04P) ZL3M (04P) Supply pressure: 0.5
, no output, 200 degree setting 55 Types LN and MN are equipped with sockets (2 pcs.).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
Status (7): TEMP READY signal output continues since the temperature is now back within the Out Time range of 200 sec even though it was temporarily outside the Low range. Status (8): TEMP READY signal turns OFF when 200 sec has passed after the temperature rises above the High range. TEMP READY alarm (AL12) is simultaneously activated.
This parameter is fixed when shipped, and cannot be modified. (200) Operation direction Direct3 (dir) or Reverse4 (rvS) can be selected. The default when shipped is direct (dir). setting 100% 200=dir 200=rvS Stroke 0% 0% 100% 0% 100% Input current Fig. 24 When the operation direction is modified, it is reflected on each item in accordance with Table 9.
On size 70, 100 and 200 the bearing cannot be removed as the bearing is press-fitted.
1500 0 150 300 450 600 750 900 1050 1200 1350 1500 Distance [mm] Distance [mm] 5) 6) Supply pressure 0.4 MPa Consumed flow rate 316 L/min (ANR) Supply pressure 0.5 MPa Consumed flow rate 390 L/min (ANR) 200 200 150 150 2s 1.5s 100 100 50 50 1.5s 1s 0.5s 1s 0.5s 0 0 -50 -50 -100 -100 -150 -150 -200 -200 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900 1050 1200 1350
Table 7-1 Water Quality Standards for Fresh Water (Tap Water) Substance Facility water Circulating water spec. spec. pH (25C) 6.5 to 8.2 6.0 to 8.0 Electrical conductivity (25C) (s/cm) *Circulating fluid 1 to 500 100 to 800 0.5 to 300 Chloride ion (mgCl-/L) Max. 200 Max.50 2-/L) Max.200 Max.50 Sulfate ion (mgSO4 Acid consumption (pH4.8) (mgCaCO3/L) Max.100 Max.50 Total hardness (mgCaCO3/L
LEMH 25 25 LEMHT32 LEMH32 20 20 Workload m[kg] Workload m[kg] 15 15 LEMHT25 LEMH25 10 10 5 5 0 0 0 200 400 600 800 1000 1200 1400 0 200 400 600 800 1000 1200 1400 Support spacing [mm] Support spacing [mm] 6.2 Handling Caution 1.
Mounting side Closed C B A A Open D Open E F F Mounting side MHL2-25DZ-X86/X86A MHL2-25D Z-X86/X86A 1 2 200 200 160 160 Gripping force [N] Gripping force [N] Pressure 0.6 MPa Pressure 0.6 MPa 0.5 MPa 120 120 0.5 MPa 0.4 MPa 0.4 MPa 80 80 0.3 MPa 0.3 MPa Closed F (Fingers closed) 40 40 0 0 40 80 120 160 200 0 0 40 80 120 160 200 [mm] Model A B C D E F Weight [g] MHL2-25DZ-X86(A) 9 106 128