Problem 3 Red ON OFF Red Flashing W-SS W-SS LED flashes red or orange or is off Problem 4 Orange Flashing OFF Green Flashing Red Flashing Red ON W-NS W-NS LED does not turn on green. Problem 5 Red Green Alternate Flashing OFF Red Flashing W-MS W-MS LED does not turn on green.
This operation could be hazardous to personnel, as their hands or feet could get caught by the clamp arm, or could lead to equipment damage. Therefore, it is important to secure as a danger zone a cylindrical area with the length of the clamp arm as its radius, and the stroke plus 20 mm as its height.
A (Part no.: ZS-46-A1) 20 20 45 30 2 5.2 30 34.6 19 5.2 14.7 47 9.6 The bracket configuration allows for mounting in four orientations.
The Grounding point should be as near as possible to the controller. Keep the grounding cable as short as possible.
AMK Series Construction Size 20 to 40 q w OUT IN t Component Parts e No.
As a guide, adjust P2, so that it could be W + P2A = P0a.
As a guide, adjust P2, so that it could be W + P2A = P0a.
3.3 W 27 0.5 0.05 Piping port D B 2-M5 x 0.8 28 10 J 6 Mounting base side B D 10 9.5 Across AA MXP10-20 Without magnet and switch rail 8 2-M3 x 0.5, depth 3.5 2-M2 x 0.4, depth 3 For magnet mounting For rail mounting 4.7 2.5 6-M3 x 0.5, depth 4 15 15 L (mm) Model G M N W H S Z J V K L MXP10-10 8 21 6.5 40 32 10 60 52.4 44 20 20 MXP10-20 20 39 7.5 65 50 20 90 82.4 74 36 36 8-8-16 16 Precision
Prevent any kind of operation which generates moment as this may cause reduced performance or damage to the body. 4. The exhaust resistance should be as small as possible to obtain max. ejector performance. There should be no shield around the exhaust port for the silencer exhaust specification.
Output deviation factor (% F.S.) 20 0.5 30 Set pressure (kPa) 40 0 50 60 0.5 70 80 90 1.0 100 80 60 40 20 50 100 150 Flow rate (l/min(ANR)) VAC side pressure (Supply pressure) (kPa) 14-8-31 32 Dimensions ITV2090 Note) Do not attempt to rotate the cable connector, as it does not turn.
I Available as double acting or single acting.
: Universal Type Seal method: Gasket seal For M5, 10-32UNF Seal method: Sealant For R, NPT thread AS-FS AS-FSG Uni-AS-FS r !
Through holes Double end taps Extension locking Easy manual unlocking B Locked A 40 to 100 20 to 32 W Retraction locking Unlocked 40 to 100 20 to 32 W A B Wide variations from 20 to 100 Standard stroke (mm) Locking direction Bore size (mm) Mounting Series 5 10 15 20 25 30 35 40 45 50 75 100 20 Through holes, double end taps common 25 Extension locking 32 40 CLQ Through holes 50 Retraction
Description End block L End block R With PD port ZQ1L-2-BSB-AS ZQ1R-2-BSB-AS Without PD port ZQ1L-1-BSB-AS ZQ1R-1-BSB-AS 5 6 Ejector body gasket for manifold Exhaust block gasket ZQ-3-005-10AS Note 2) ZQ-3-009-10AS Note 2) Note 1) Refer to pages 1 and 2 for detailed description of How to Order. Note 2) 10 pcs. are included in one set.
Keep wiring as short as possible to prevent interference from electromagnetic noise and surge voltage. Do not use a cable longer than 20 m. Wire the DC(-) line (blue) as close as possible to the power supply.
Condition 1) Length to work In position ] Condition 2) Length to work In position 5 (Length to work) W Position[mm] c In pos[mm] k 10 0 5 10 15 20 25 Stroke [mm] INPOutput condition k In pos Length to work The INP output signal is turned on Actual force g TriggerLV (Length to work) 15 W Position[mm] c In pos[mm] k 10 0 5 10 15 20 25 Stroke [mm] INPOutput condition The INP output signal
Pressure gauge unit 2) w q w q w q Unit psig/bar MPa Code No code MPA Sample Order Number Port AP1001S e q FV4 FV4 FV4 FV4 w FV4 FV4 FV4 FV4 r 2PW 3PW 2PW 3PW 3PW 4PW 2) Pressure gauge unit MPa or psig/bar selectable.
As the circulating fluid temperature at this time is 20 oC, "AS.06" starts alarm monitoring at the same time as the operation start. Status (2): The circulating fluid temperature becomes within the set range of "AS.04", and starts "AS.04" alarm monitoring".
Burst Pressure Characteristics Curve and Operating Pressure How to Order 5 TPS0604 B 20 4 Burst pressure (MPa) Tubing model Burst pressure 3 Color Length per roll Color White Black Red Blue Yellow Green Symbol W B R BU Y G Length 20 m roll 100 m reel Symbol 20 100 Max. operating pressure 2 1 20 0 0 20 40 60 80 Operating temperature (C) 15-6-23 1 Miniature Tubing and Miniature Fittings Series
25 5 5 20 20 25 16 20 16 25 20 16 16 1 1 0.5 10 20 25 26 50 100 200 400 0.5 10 20 25 26 50 100 200 400 Stroke [mm] Stroke [mm] 460 Model Selection MGP Series Horizontal Mounting Ball Bushing (19) L = 50 mm, V = 200 mm/s or less (20) L = 100 mm, V = 200 mm/s or less MGPL16 to 25 MGPL16 to 25 10 10 25 25 25 20 25 20 5 5 20 16 20 Load mass m [kg] Load mass m [kg] 16 16 16 1 1 0.5 20 50 76 75