(A clearance of 40 or more is required.) (60) (74.7) 101.7 60 (40) 80 40 74.7 27 27 4H7 depth 5 Motor 72 43.5 50 42 60 102 102 50.4 40 5 5.1 40 3.5 40 Long hole depth 5 Controller 4 15.5 6 7.2 5.6 (Max. 8.6) 14.4 6.5 4H7 2-6.5 counterbore depth 3.3 28 (60.3) 87.3 2 x 2-3.3 through hole 4 152 + Stroke 4-M4 x 0.7 depth 7 FG terminal M3 T-slot section for mounting I/O cable (9 wires) 5.8 3.5
The cushion effect (smooth start-up, soft stop) is not available an intermediate stop or return from an intermediate stop using an external stopper, etc. When using an intermediate stop with the above information taken into account, implement measures to prevent particulate generation and set the operating pressure to no more than 0.3MPa.
flange) Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.
It will lead to an operation failure. Caution 1. This product does not have a filtering function. Install an air filter on the supply side close to the product. Select an air filter with a filtration degree of 5 m or finer. 2. Compressed air containing large amounts of drainage can cause a malfunction of this product and other pneumatic equipment.
Note 3) K (High pressure) and Y (Low wattage) are not available. Electrical ently: L/ M plug connector only.
Never use in an atmosphere of explosive gases. The structure of switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Mount switches in locations without vibration (98m/s or less) or impact (490m/s or less). 3. Do not use in an area where surges are generated.
I l 50i 70 , iiFl.r* 0 q . . , . 50 6o ' 3 0 3o , , , . 3 0 , : LXPB5SA 40 40 '" .,1 i Slide Screw \ I i LXPB5SB 2D 2A LXSH2BC 100 50 220 High rigidity linear guide Ball LXSH2BD 100 50 90 Screw LXSH5BC 1 0 0 50 1 6 0 LXSH5BD 1 0 0 50 70 LXSH2SA 90 40 60 Slide LXSH2SB 45 20 30 Screw LXSHSSA 60 20 40 LXSH5SB 30 1 0 20 , \ | '-t 'oo"ot| I PLc I ll'i;!:-,?
Connector with cable or without cable may be selected when placing an order for the power supply cable. When only an e-con is required, place an order for it as a part.
, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 Surge voltage suppressor Diode (Non-polar: Varistor) 32 1 Indicator light LED Note) The S and Z types of surge voltage suppressor have an internal circuit allowing voltage drop, so use within the following allowable voltage range.
In the case of mixed wiring, use the option symbol "-K".
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: A (w/Caster Adjuster-foot)
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: AK (w/Caster Adjuster-foot and Fluid Fill Port)
Cooling Capacity: 100 (10 kW), Cooling Method: W (Water-cooled), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: A (w/Caster Adjuster-foot)
Cooling Capacity: 100 (10 kW), Cooling Method: W (Water-cooled), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: AK (w/Caster Adjuster-foot and Fluid Fill Port)
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: w/Caster Adjuster-foot
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: w/Caster Adjuster-foot and Fluid Fill Port
Cooling Capacity: 10 kW, Cooling Method: Water-cooled, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: w/Caster Adjuster-foot
Cooling Capacity: 100 (10 kW), Cooling Method: W (Water-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: AK (w/Caster Adjuster-foot and Fluid Fill Port)
Cooling Capacity: 100 (10 kW), Cooling Method: W (Water-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: KW (w/Fluid Fill Port, Manual Fill and SI Unit Only)