Install an air filter. Install an air filter on the inlet side in close proximity with the regulator. Select a type with 5 m or smaller filtration. 2. Install an after cooler, air dryer or mist separator (drain catch) to remove drainage. Compressed air containing excessive drainage may cause malfunction of the regulator, pressure switch or other pneumatic equipment. 3.
Install an air filter. Install an air filter on the inlet side in close proximity with the regulator. Select a type with 5 m or smaller filtration. 2. Install an after cooler, air dryer or mist separator (drain catch) to remove drainage. Compressed air containing excessive drainage may cause malfunction of the regulator, pressure switch or other pneumatic equipment. 3.
IO-Link device) 12 to 24 VDC 10% with 10% voltage ripple or less Power supply voltage When used as an IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Current consumption 35 mA or less Protection Polarity protection Power supply Accuracy Display accuracy 2% F .S. 1 digit (Ambient temperature of 25 3C) Repeatability 0.2% F .S. 1 digit Temperature characteristics 2% F .S. (25C standard
to 8E-10 IDU3E-10, 4E-10 500 VA IDF-TR500-2 Output sealing C A Output outlet Input fuse 5A Voltage selector B 220V INPUT 200V 230V 240V E D 4-5.5 x 10 long hole F Input cord 2 m Transformer part no.
Applicable bore size Dd9 L1 L2 m d Drill through Included split pin Included flat washer Clevis Knuckle 2 x d Dd9 CDP-2A 40 10 0.040 0.076 46 38 4 3 3 x 18 L Polished round 10 L1 L2 m L1 L2 m CDP-3A 50 40, 50, 63 12 0.050 0.093 55.5 47.5 4 3 3 x 18 L Polished round 12 2 x d Dd9 CDP-4A 63 16 0.050 0.093 71 61 5 4 4 x 25 L Polished round 16 L1 L2 m CDP-5A 80 18 0.050 0.093 76.5 66.5 5 4
Load weight m (kg) Load weight m (kg) 30 CXW 30 40 50 32 20 CXS 10 20 CXT 5 4 10 MX 3 5 MXU 200 2 3 4 5 20 30 40 50 10 1 100 1 100 10 200 20 30 40 50 2 3 4 5 Eccentric distance l (mm) Eccentric distance l (mm) MXS 75 to 124 stroke 50 to 74 stroke MXQ 100 100 200 63 P=0.5MPa P=0.5MPa MXF 80 50 40 50 100 MXW 40 Load weight m (kg) Load weight m (kg) 30 40 50 32 MXP 20 30 MG 10 20 MGP 5 4 3
Lead wire length symbols: 0.5 mNil (Example) A53 3 m L (Example) A53L 5 m Z (Example) A53Z Auto switches marked with are made-to-order specifications.
The range in the chart below that is delineated by bold solid lines indicates the relation between load weights and maximum driving speeds. 6 8 10 4 Bore size (mm) 0.05 to 0.5 Operating piston speed (m/s) 3.8 x 10-3 6.25 x 10-3 9.35 x 10-3 12.5 x 10-3 Allowable kinetic energy (J) 10 6 8 10 1 Load weight kg 4 0.1 0.01 0.1 1.0 0.01 Maximum speed V (m/s) 22 Series CUJ Specific Product Precautions
Without arm Q R M MK MK 20 MK2T 8 19 CK1 17 0.1 0.2 Q (mm) CLK2 Q (mm) Rod state Clamp stroke 10 mm Model Q 10 mm 20 mm Clamp stroke CLKG Rod state Bore size 50 mm 20 mm 30 mm 50 mm Retracted 146.5 175.5 166.5 205.5 186.5 235.5 226.5 295.5 R M Q 82 82 83 83 91.5 91.5 85 85 96.5 96.5 100 100 R 33.5 63 35.5 65 50 85 57.5 92.5 65.5 104.5 65 104 M Q 126.5 126.5 130 130 R 95.5 164.5 95 164 M MK63
-m-m PFA750-m-m Dry air, N2 Heater type 1 to 10l/min (0.04 to 0.35SCFM) 0.1l/min (0.004SCFM) 5 to 50l/min (0.18 to 1.77SCFM) 0.5l/min (0.02SCFM) l/min, CFM x 10-2 Instantaneous flow rate Cumulative flow rate Display units l, ft3 x 10-1 0 to 0.5MPa (0 to 72psi) 1.0MPa (145psi) 3kPa (50l/min) [0.44psi (1.77SCFM)] 0 to 9l (0 to 35,300 ft3) 0 to 50C (32 to 122F) with no condensation 5% F.S.
M B O L S NAM450-N06D 34 225 106 10 NAM550-N10D 1" 259 122 10 NAM650-N14D 112" 361 160 10 NAM850-N14D 2" 473 220 10 Manual and Autodrain types are same overall dimensions.
F: Angle adjustment range 5 E: Angle adjustment range 5 E: Angle adjustment range 5 B port Angle adjustment screw A port Clockwise rotation 0 8 0 e Allowable Lateral Load to the Piston Rod End gl 10 n a e nt gl e an m st t en u dj m a m st u ju m i in ad M Using friction fittings makes it easier to mount the load to the piston rod end.
Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for every additional 5 m. (At 15 m: Reduced by up to 20%) 12. When checking the conductivity of the cable, be careful not to deform the connectors mating hole and terminals.
m 0.3 MPa Graph (5) F 0.4 MPa Graph (6) m 0.5 MPa Graph (7) F 9-6-6 7 Model Selection Series MNB Selection Graph Graph (5) Graph (2) 0.3 MPa P < 0.4 MPa 0.3 MPa P < 0.4 MPa 1000 1000 500 400 300 500 400 300 100 100 80 80 200 200 63 63 100 100 50 50 40 40 80 80 100 100 Load weight: m (kg) Load weight: m (kg) CL 63 63 50 40 30 50 40 30 32 32 50 50 40 40 CL1 20 20 32 32 MLGC 10 10 CNG
m 0.3 MPa Graph (5) F 0.4 MPa Graph (6) m 0.5 MPa Graph (7) F 9-6-6 7 Model Selection Series MNB Selection Graph Graph (5) Graph (2) 0.3 MPa P < 0.4 MPa 0.3 MPa P < 0.4 MPa 1000 1000 500 400 300 500 400 300 100 100 80 80 200 200 63 63 100 100 50 50 40 40 80 80 100 100 Load weight: m (kg) Load weight: m (kg) CL 63 63 50 40 30 50 40 30 32 32 50 50 40 40 CL1 20 20 32 32 MLGC 10 10 CNG
Furthermore, it cannot be used as an emergency cutoff valve.
D-M9m m: Operating range Size q m: Operating range q d: Hysteresis range 10, 15 170 20 20, 30 100 15 40 86 10 Actuated position: ON Auto switch d: Hysteresis range OFF D-S/T99(V)m, S9P(V), S/T79, S7P, D-97/93A, 90/90A, R73/80m (OFF) Magnet Size q m: Operating range q d: Hysteresis range 10, 15 110 10 20, 30 90 40 52 8 Note) Since the figures in the above table are provided as a guideline
Set the mounting band perpendicularly to cylinder tube. 20 50 63 80 100 25 32 40 D-B7/B80 8 10 9 10 10 11 D-B73C/B80C D-C7/C80 8 10 9 10 10 11 D-C73C/C80C 8 10 9 10 10 11 D-B5/B64 11 11 MX Mounting correctly Mounting incorrectly 13 13 14 14 14 17 D-B59W 18 16 D-G79/K79 8 10 9 10 10 11 Auto Switch Mounting Bracket Part No.
vr'hen 3 pos to. manifold a lalves m!
Confirm that the value is within the operating range of the point of application L = 60 mm. 10 10 RZQ 5 5 MI W S CEP1 1 1 kg 1 CE1 CE2 0.25 kg ML2B 10 20 40 5 10 20 30 C J G5-S 32.5 m/min Transfer speed (m/min) Transfer speed (m/min) 12 m/min CV Procedure 3: Confirmation of allowable lateral load MVGQ MIW12 MIS12 1.