Air suction filter 13-10-1 Series ZFA Using an ejector with a 2-stage nozzle, the ejector system can be used most efficiently. Air suction filter 13-10-4 Prevents problems related to vacuum circuits or airborne contaminants.
Bellows, O-ring Seal P.20 to P.25 105 to 10-6 10-10 10-11 2 Eliminates pump over loads XLDV (With solenoid valve) Standard For portable equipment not requiring air Standard XLH Bellows Seal Standard 105 to 10-6 10-10 10-11 0.1 P.26, P.27 Manual Particulate free completely cleaned Single acting (N.C.)
10 to 300 701800 Note2) Stroke 30 to 930 20 to 620 10 to 300 801900 Speed range [mm/s] 30 to 780 20 to 520 10 to 250 9011000 30 to 660 20 to 440 10 to 220 10011100 Actuator specification 30 to 570 20 to 380 10 to 190 11011200 20 to 500 30 to 500 10 to 250 1000 Driver type LECPA Note2) Stroke 30 to 500 20 to 440 10 to 220 Speed 10011100 range [mm/s] 30 to 500 20 to 380 10 to 190 11011200
Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.
CL 2 5 0 0 10 20 30 40 50 60 70 80 Vacuum pressure [kPa] 0 0 10 20 30 40 50 60 70 80 Vacuum pressure [kPa] ZP3E-50BM ZP3E-125BM ZP3 12 30 S, F S, F 25 Displacement [mm] Displacement [mm] ZP3E ZP3E 20 8 N N ZP2 15 U U 10 4 ZP2V CL CL 5 ZP 0 0 10 20 30 40 50 60 70 80 Vacuum pressure [kPa] 0 0 10 20 30 40 50 60 70 80 Vacuum pressure [kPa] ZPT ZPR ZP3E-63BM XT661 16 N, S, F Displacement [mm]
/F79F/F7NT 10 15 15 + 20 (n 2) (n = 4, 6)4 D-F7WV D-F7BAV 10 15 10 + 15 (n 2) (n = 4, 6)4 D-A7/A80 D-A7H/A80H D-A73C/A80C 5 10 15 + 10 (n 2) (n = 4, 6)4 D-A7H D-A80H 5 10 15 + 15 (n 2) (n = 4, 6)4 D-A79W 10 15 10 + 15 (n 2) (n = 4, 6)4 3: When n is an odd number, an even number that is one larger than this odd number is used for the calculation. 4: When n is an odd number,
) 24VDC (10%) 24VDC (10%) 100 to 240VAC (10%) 100 to 240VAC (10%) 100 to 240VAC (10%) 24VDC (10%) 100 to 240VAC (10%) Power consumption 20VA or less 10W or less 20VA or less 10W or less 20VA or less 10W or less 10W or less 20VA or less Between case and AC line: 1500VAC for 1 min.
6 KA 78 79 77 77 S 16 12 10 8 D 25 18 14 12 E 2 2 2 2 F 40 32 25 20 30 22 22 18 23 0<23> 0 0 10 0 0 0 M5 x 0.8 depth 7.5 M5 x 0.8 depth 8 M14 x 1.5 M6 x 1 depth 12 12 12 1/4 1/4 3/8 1/2 58 58 27 27 32 41 14<12> 14<12> 10 10 10 10 23 20 20 20 11 11 58 72 20<17> 20<17> 16 16 71 71 13 16 89 110 7 7 10 10 55 69 80 100 10 10 10 10 32 38 50 60 150 150 182 182 18 18 22 26 90 90 108 108 20 20 25
200 200 200 0 0 0 0 0 5 10 15 20 25 30 35 40 0 10 20 30 40 50 60 70 0 5 10 15 20 0 10 20 30 40 50 60 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 1000 800 800 800 800 Mep L3 [mm] L3 [mm] L3 [mm] L3 [mm] m 600 600 600 600 L3 Z 400 400 400 400 200 200 200 200 0 0 0 0 0 5 10 15 20 25 30 35 40 0 10 20 30 40 50 60 70 0 5 10 15 20 0 10 20 30 40 50 60 Work load [kg
to 10 (832) Integrated time setting; -10 to 10 (833) Differentiation time setting; -10 to 10 Table 13 Amount of change when set value is increased/ decreased by 1 Set value is 0 or more Set value is less than 0 Prop. gain 10% 10% Integ. time 50% 10% Deffer. time 10% 10% 8: When automation calibration is performed, PID constant is automatically set.
Bore size (mm) 10 15 25 10 15 25 Auto switch Nil Without auto switch Refer to the table below for auto switch model numbers.
Series 10-/11-/21-/22-CDG1 Series 10-/11-REC Series 10-/11-CDM2X Series Perpendicular entry is unavailable.
(Refer to page 127) 10 Pressure ramp up duration Configurable parameter. (Refer to page 127) 11 Soft start function Mechanical, configurable by an adjusting screw on the product. -40No.PF-OMA1007-B Timing Chart The following figure shows an example timing diagram for the NC type AMS##A and NO type AMS##B.
to an axial rotation angle.
Tighten the retaining screws to an appropriate tightening torque within the range given below. 6: 2.1 to 2.5 Nm, 10: 5.9 to 6.4 Nm, 16: 10.8 to 11.8 Nm 3.
3.14-10 Technical Information Channel selection function 13 Channel Selection Function is explained with an example when adsorbing work.
Please See Below for How to Order Piston Rod Assembly 7 Rod Bushing Bronze casting Available only as an Assembly Please See Rod/Head Cover NC1A400-10-124 NC1A200-10-124 NC1A250-10-124 NC1A325-10-124 8 Cushion Valve Carbon steel NC1A150-10-124 9 Tie Rod Carbon steel Please See Below for How to Order Tie Rod NCA325-13-Q6311 5008-131 NCA325-31-Q6311 NCA200-13-Q6309 5008-93 NCA250-13-Q6309 5008
70 0.01 2 40 6000 100 40 0.1 3 90 1000 20 1 4 10 +3 5 5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.
. 3 8 10 stations 10 Base type 01T, 10: 2 to 10 stations Base type 01C, 01F: 2 to 8 stations Symbol Porting specifications (A, B) Passage Symbol R1, R2 P 1 Side 2 Bottom Common Common Caution Option When using an exhaust cleaner, mount it downwards.
No freezing (for cylinders with or without an auto switch) Bore Size/Standard Stroke Symbol Specifications (mm) XA Change of rod end shape Rod end configuration XC3 Special port location Bore size (mm) Round bar, Chamfered type Roller type Lever type with shock absorber 12 10 10 16 10, 15 10, 15 20 10, 15, 20 10, 15, 20 32 10, 15, 20 40 Spring Force (Single acting) 20, 25, 30 20, 25, 30