KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 32 35 39 43 16 18 32 35 39 43 6 8 10 12 6 8.5 10 20.5 22 20.5 22 11.5 Port plug VVQ1000-58A The plug is used to block the cylinder port.
the connections from Rc to NPT is enclosed as an accessory.
HF10% or less 10 to 40oC Note 2) HF5% or less Hydrofluoric acid and Nitric acid mixture HNO35% or less Nitric acid HNO35% or less Hydrochloric acid HCl5% or less Copper sulfate solution H2SO496% or less 10 to 50oC note) HED007:10 to 30oC Note 2) Sulfuric acid H2SO496% or less 10 to 50oC note) HED007:10 to 30oC Note 2) Ozone 10 to 60oC Ammonium hydroxide NH35% or less 10 to 60oC Note
Connect the remote control cable and the switch to the connector for the contact input/output, supplied as an accessory. Then, mount the ferrite core (3 turn) supplied as an accessory. (See below) (This is an example of wiring. Refer to the Operation Manual for communication for details.)
Select an air-hydro type in combination with an air-hydro unit. Since good operation of an air-hydro type depends on its combination with an air-hydro unit, carefully select an appropriate air-hydro unit. Maintenance Caution 1. Bleed air from the air-hydro type on a regular basis. Since air may accumulate inside the air-hydro type, bleed air from it, for example before starting work.
This value can be used for the selection of the power supply. * 9 Only when the motor option, "with lock", is selected. *10 For an actuator with lock, add the power consumption for the lock.
Note 3) When connecting the M8 plug connector, the tightening torque must be 0.2 Nm 10%. If tightened with an excessive tightening torque, this may cause the connector thread of the Unit to break.
5.25 21 F9E8 63976 10 5 20 BCF4 48372 5 2.5 10 8000 32768 0 0 0 430C 17164 -5 -2.5 -10 0618 1560 -10 -5 -20 0 0 -10.5 -5.25 -21 Data format Byte0 Byte1 CH0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD value LSB Byte2 Byte3 CH1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD value LSB -21No.EX-OMN0038-C (2)Signed binary data format and twos complement data format Input signal range: 0 to 10 V
Connect the remote control cable and the switch to the connector for the contact input/output, supplied as an accessory. Then, mount the ferrite core (3 turn) supplied as an accessory. (See below) (This is an example of wiring. Refer to the Operation Manual for communication for details.)
Double clevis type mm Bore size (mm) Stroke range (mm) CD hole H10 Shaft d9 CL CD CT CU CW CX CZ L A B 63 107 55 30 to 100 93 14 8 20 30 22 44 8 80 129.5 63.5 40 to 100 111.5 18 10 27 38 28 56 10 100 155 76 L CU CW RR 40 to 100 133 22 13 31 45 32 64 12 CX CZ +0.4 +0.2 0.1 0.3 B + Stroke CL + Stroke A + Stroke Bore size (mm) Stroke range (mm) 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75,
An example of an environment of this degree is a factory. Degree 3 Degree 4 Conductive pollution that holds its conductivity due to conductive dust, rain or snow. An example of an environment of this degree is the outdoors.
Specifications Model MSUA1 MSUA3 MSUA7 MSUA20 Vane Type Single vane Rotating angle *1) 90 o 180 o 90 o 180 o 90 o 180 o 90 o 180 o +/10 o +/10 o +/10 o +/10 o +/10 o +/10 o +/10 o +/10 o Fluid Air (Non-lube) Proof pressure 1.05 MPa 1.5 MPa Ambient and fluid temperature 5 to 60 oC Operating pressure range 0.2 to 0.7 MPa 0.15 to 0.7 MPa 0.15 to 1.0 MPa Rotation time adjustment range 0.07 to
SS5V2-10 SS5V3-10 SS5V4-10 Note) The value is for manifold base with 5 stations and individually operated 2 position type.
to 10 (832) Integrated time setting; -10 to 10 (833) Differentiation time setting; -10 to 10 Table 12 Amount of change when set value is increased/ decreased by 1 Set value is 0 or more Set value is less than 0 Prop. gain 10% 10% Integ. time 50% 10% Deffer. time 10% 10% 8: When automation calibration is performed, PID constant is automatically set.
^ rtl-,| 1 q 1 0 s l a l o n s Add an adansk (*) at lhe bginning of slsclro.pneumalic regulator part Note) A DIN raitwirh t.le length specilied by ihe numberol stalions is atlached 10 the manifold.
5.5 M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1.0 32 38 47 52 5 6 8 10 3.5 3.5 4.5 5 15.5 20 25.5 28 3.5 3.5 5.4 5.4 M4 x 0.7 M4 x 0.7 M6 x 1.0 M6 x 1.0 6.5 6.5 9 9 7.5 7.5 9 11 7 7 10 10 4 4 7 7 0.5 0.5 1 1 Note 1) Threaded through hole is used for the standard of 20 with 5 to 10 mm strokes and 25 with a 5 mm stroke.
10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 10 102 1.
ZK2-OM01301 Manifold ZZK2 04 A A 1 L 00 00 (1) (2) (3) (4) (5) (6) Remains blank when no option is selected. (1) Number of stations Note 1) Symbol Stations 01 1 station 02 2 stations 10 10 stations Note 1) In the case of an ejector, for an adequate performance, the number of stations when operated simultaneously depends on the nozzle diameter.
^ rtl-,| 1 q 1 0 s l a l o n s Add an adansk (*) at lhe bginning of slsclro.pneumalic regulator part Note) A DIN raitwirh t.le length specilied by ihe numberol stalions is atlached 10 the manifold.
If a surge voltage suppressor is installed, the return speed decreases. r Operate at a voltage in the range of 10% to +10% of the rated voltage. Environment Caution q Operate under conditions that are free of vibration and impacts. w Operate in an ambient temperature range between 0C and 50C. e Operate in an ambient humidity range between 35% to 85% (no condensation).