(5.1) 10 5.8 4 5.5 36 1 0.2 6.5 6.5 1 3 39 28 10.5 3.3 T-slot A +0.030 0 depth 4 +0.030 0 depth 4 C 4H9 L-M6 Refer to Cross section C-C.
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% VS4 VQ7 EVS Conditions VFN Base mounted Series MB Series CS1 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 6A x 1 m AS4000-02 AN200-02 10A x 1 m AS420-03 AN300-03 Base mounted Series MB Series CS1 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 10A x 1 m AS4000-03 AN300-03 15A x 1 m AS420-04 AN400-04 SGP (Steel
(For 20, 41, 42 and 45 Types) Pilot pressure range SS5YA Fill the same as SS5Y . 3 5 7 3 5 7 Pilot pressure MPa (Refer to Best Pneumatics No. 1-1.) Specify the part numbers for valves and options together beneath the manifold base part number.
C Pressure gauge mounting bore 1/8 4-R R 4-R 36.8 E 36.8 E R P P D D + + MADE IN JAPAN MADE IN JAPAN SMC SMC Model Port size A B C D E G H I K L M N P Q R AV2000-02-G AV2000-02-GS AV2000-02-D AV2000-02-DZ AV2000-02-Y AV2000-02-YZ AV3000-03-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000
(C) Correction factor 1.14 Ambient temp. (C) Correction factor 1.10 Ambient temp. (C) Correction factor 1.2 Ambient temp.
OUT (2) 2 Port size (1) IN Port size 1/8 (6A) Symbol 01 02 03 04 06 Class 3 Class 2 Class 4 Voltage 1/4 (8A) 3/8 (10A) 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC 1/2 (15A) 3/4 (20A) Orifice size Orifice size (mm) Class 3 Class 2 Class 4 Symbol 2 3 4 5 7 10 Please consult with SMC regarding other voltages. 2 3 4 5 7 10 Electrical entry G Grommet C Conduit Note) Note
Alarm indication and trouble shooting . 7-1 7.1 Alarm Display . 7-1 7.2 Alarm buzzer stop . 7-3 7.3 Troubleshooting . 7-4 7.3.1 Alarm contents, causes and remodies . 7-4 7.3.2 How to release the fan breaker trip . 7-8 7.3.3 How to release the pump thermal trip . 7-10 7.4 Other Errors . 7-12 Chapter 8 Control, Inspection and Cleaning . 8-1 8.1 Control of Circulating Fluid, facility water Quality
Control, Inspection and Cleaning . 7-1 7.1 Quality Control of Circulating Fluid and Facility Water . 7-1 7.2 Inspection and Cleaning . 7-2 7.2.1 Daily check . 7-2 7.2.2 Monthly check . 7-4 7.2.3 Inspection every 3 months . 7-5 7.2.4 Inspection during winter season . 7-7 7.3 Consumables . 7-7 7.4 Operation Stop for an Extended Period of Time . 7-8 7.4.1 Discharge of the circulating fluid .
Component parts Replacement parts No. 1 2 3 4 5 6 No. 7 8 Description Description Sub-plate Pilot valve Note Aluminum die-casted No.
Flow Characteristics Series Flow characteristics C [(dm3/sbar)] b Cv 0.12 0.21 0.74 0.36 0.32 0.35 0.46 0.83 2.9 SYJ3000 SYJ5000 SYJ7000 Cover (stainless steel) Rubber seal 4/5 Port Solenoid Valve Series SYJ3000/5000/7000 Variations Option Manual override Sonic conductance: C [dm3/(s.bar)] Type of actuation Series Voltage Electrical entry With light/surge voltage suppressor SYJ3000 For DC
Size d Model H D1 D2 D3 D4 L1 L2 L3 L4 L5 L6 A1 A2 M1 T Weight (g) 17 ASD230F-M5-04D ASD230F-M5-06D ASD330F-01-06SD ASD330F-01-08SD ASD430F-02-06SD ASD430F-02-08SD ASD430F-02-10SD ASD530F-02-06SD ASD530F-02-08SD ASD530F-02-10SD ASD530F-02-12SD ASD530F-03-06SD ASD530F-03-08SD ASD530F-03-10SD ASD530F-03-12SD ASD630F-04-10SD ASD630F-04-12SD 4 9.3 29.4 17.5 12.9 8 9.6 10 4.7 11.7 30.7 31 0.7
34.7 26 2 x M3 x 0.5 thread depth 10 11 291 *1 Dimension of the resin part in described in the Mounting Warning note 3 (page 24). 18.31 One-touch fitting (Elbow) IZN10E-mm 16 17 D B C Applicable tubing O.D. d 180 [mm] Model d B C D IZN10E-mm16 6 22 16 11.5 IZN10E-mm17 1/4" 24.5 18.5 12 Female threads for piping (Rc1/8) IZN10E-11mm 14 Rc1/8 5 Width across flats 12 10.6 17 Nozzle Type Ionizer
COIL TEMPERATURE CLASS CHART Class A 105 C / 221 F Class B 130 C / 226 F Class F 155 C / 311 F Class H 180 C / 356 F Class N 200 C / 392 F Class C 220 C / 428 F 86 86 SOLENOID VALVES . . . Valve Types and Function Three-Way Valve a valve that has two orifices and three ports. One orifice is always open when the other is closed and one port is always open to one of the other two ports.
Port size ASV Model M3 x 0.5 ASV120F-M3 0.3 0.3 AK M5 x 0.8 ASV220F-M5 1.3 1.3 R 1/8 ASV310F-01 8 7 ASS R 1/4 ASV310F-02 8 7 R 1/8 ASV410F-01 14 13.5 ASR R 1/4 ASV410F-02 14 13.5 R 3/8 ASV410F-03 14 13.5 ASF R 1/4 ASV510F-02 27 23 R 3/8 ASV510F-03 29 27 R 1/2 ASV510F-04 29 27 10-32 UNF ASV220F-U10/32 1.3 1.3 NPT 1/8 ASV310F-N01 8 7 NPT 1/4 ASV310F-N02 8 7 NPT 1/8 ASV410F-N01 14 13.5 NPT 1
(For details, refer to catalog on page 22.) 17 Series SYJ500 Construction c f a e b d c f a e b d N.C. N.O.
connectors, so switching from the F kit (D-sub connector) to the S kit (serial transmission) can be done simply by changing the kit section. 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 6 7 8 9 10 (Refer to the connector wiring diagram.)
O 5/32 P 3/16 U 7/32 R 1/4 A 9/32 S 5/16 T 3/8 V 5/64 B 1/2 C 5/8 D 1 E 1 1/2 Y 3/4 F 2 W 3 D No Option Ports T Metering (1/32 1/8 orif.)
HRZ x V x C x iT it m x C x (T0 Tt) it Q = = HRZD 1 x 150 x 4.186 x 103 x 10 900 = = 6977 [J/s] 7.0 [kW] m x C x (T0 Tt) it x 860 x V x 60 x C x iT it x 860 HRW Q = = Cooling capacity = Considering a safety factor of 20%, 7.0 [kW] x 1.2 = HECR 1 x 150 x 60 x 1.0 x 103 x 10 15 x 860 8.4 [kW] = HEC Q x t: Heat capacity [kJ] Thermo-chiller Water bath 6977 [W] = 7.0 [kW] 20C HEB Cooling
D D C CHK H B B H Material: Carbon steel Material: Carbon steel CHN Part no. d H B C D Applicable bore size (mm) NT-02 NT-03 NT-04 AC-NI-50 Part no. d H B C D Applicable bore size (mm) SO-02 SO-03 SO-04 SO-05 CHM CHM 8 8 9 11 5 6 8 10 12.5 16.5 21.0 23 20 25 32 40 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 26 32 38 41 30 36.9 43.9 47.3 15.0 19.6 25.4 27.7 20 25 32 40 M22 x 1.5 M24 x 1.5 M30