<br>When the LED is ON (red), this indicates a high-voltage error has occurred.<br>The main cause of this is usually foreign matter or water droplets adhering to the emitter (electrode needle).<br>Remove the cartridge and clean the emitter after stopping the power supply and air supply.
<br>Brackets can only be retrofitted for valves with an “XNB” part number suffix as they feature mounting holes on the bottom surface of the body. <br>Some VXD and VXZ series valves can be retrofitted with brackets depending on the model. <br><br>Note 1) The type with a resin body comes with brackets as standard.
<br>Keep in mind that if you wish to make changes after purchase, disassembly is required, which will void the product warranty. <br>Refer to the “Disassembly/Assembly Procedures” in the “Specific Product Precautions” section at the end of the catalog. (The VXZ series valve is not listed.) <br>The VX series catalog can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=fluid-process-valves&fa_id=10545
<br>Due to the pilot type structure, a pressure differential between the inlet and outlet sides is required. <br>Check the catalog to see if the product is suitable for your application. <br>The VQ20/30 series catalog can be found here.
<br>Therefore, these valves cannot be used in circuits that require the pure water to retain its level of purity. <br>For such circuits, consider using a product from the LV series. <br>The LV series catalog can be found here.<br><br>
<br>For piping connection, pipe the vacuum pump to the A port side of the valve. <br>If the B port side is used as a vacuum source, the service life of the product may be shortened. <br>Note) LVA and LVC series valves cannot be used with chemical gases. <br>Also, they cannot be used for vacuum retention. <br>The LVA series catalog can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=high-purity&fa_id=11182
<br>When using pure water (deionized water), select option “M” (deionized water piping). <br>This specification does not use copper-based materials for the wetted parts of the circulating fluid circuit. <br>Note 1) For details on water quality standards, refer to the HRS series “Specific Product Precautions.”
<br>Note 1) The discharge pressure can be set for HRSH series thermo-chillers. <br>Note 2) The pressure cannot be displayed for HRSE series thermo-chillers.
<br>Check that there is no restriction in the piping, including the customer’s device. <br>If there is restriction, thicken the piping or relieve the circulating fluid flow rate with a bypass piping set. <br>Depending on the problem, however, consider requesting maintenance from a maintenance company. <br>We can recommend service providers if needed.
<br>Alarm code “AL28” (pump maintenance) will be activated every 20,000 hours (every 8000 hours for option “T” and the HRS050/060) of operation. <br>Consider requesting maintenance from a maintenance company. <br>We can recommend service providers if needed.
<br>Even if there is no leakage, replacement of the mechanical seal is recommended. <br>The mechanical seal can be replaced up to 2 times. If foreign matter enters the circulating fluid, leakage may occur earlier. <br>For protection of the mechanical seal pump, we recommend the installation of a particle filter.
<br>When replacing, follow the replacement procedure in the operation manual and the element replacement procedure (published on the SMC website). <br>The FGD series catalog can be found here. <br>The FQ1 series catalog can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=industrial-filters&fa_id=10645
<br>Note) Single-side air driving of SMC hydraulic cylinders is possible, but the increased pressure will drop if air gets inside the air-hydro booster, so be sure to drive both sides with oil whenever possible.<br><br>
<br>Refer to the following formulas for converting the displayed values. <br>sonic conductance C x 5 = effective area S[mm2]<br>Cv x 18 ≈ effective area S[mm2]<br><br>
SMC's CLK2 series is a perfect choice for holding applications in either a clamped or unclamped state. CLK2 cylinders have a compact lock mechanism which minimizes the extension of the length dimension (2mm shorter), while maintaining the mounting interchangeability with the CLK1 existing product line. The CLK2 is capable of being locked at any position within the entire stroke. A dedicated
SMC's CLK2 series is a perfect choice for holding applications in either a clamped or unclamped state. CLK2 cylinders have a compact lock mechanism which minimizes the extension of the length dimension (2mm shorter), while maintaining the mounting interchangeability with the CLK1 existing product line. The CLK2 is capable of being locked at any position within the entire stroke. A dedicated
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com