4 A 4 A 4 A 4 A R 62 41.5 (58) 39.5 P B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 25.5 1 21 44.5 63.5 P = 17.5 2n-C4,C6,C8 A, B port Dimensions Formulae L1 = 17.5n + 52 L2 = 17.5n + 74.5 n: Stations (max. 16 stations) L n 1 69.5 92 112.5 123 2 87 109.5 137.5 148 3 104.5 127 150 160.5 4 122 144.5 175 185.5 5 139.5 162 187.5 198 6 157 179.5 200 210.5 7 174.5 197 225 235.5 8 192 214.5 237.5 248 9 209.5
Pin description A B Output specification 1 DC(+) Output for display unit only 42 62 2 NC/Analog output 3 DC() Output for display unit + Analog output 52 72 4 OUT Flow direction 22 Series PF2W Dimensions: Remote Type Sensor Unit for Water PF2W511-(N)B 148 32 80 70 58 46 45 36 2-Port size 45 2 4-5.5 (44.2) A (mm) A B Output specification Output for display unit only 63 77 Output for display
Fiber element (Cotton) Housing O-ring material N V NBR FPM Part number Dimensions Filtration accuracy (m) Element symbol Element sealing method 0.5 1 5 10 20 50 75 100 EH10G EH39R10GV EH23R10GV EH19R10GV EH15R10G EH11R10G EH10R10G EH8R10G HX50 H001 H005 H010 H020 H050 H075 H100 Options Flat gasket (D.O.E) 1 N/A Bracket Quick plug Nil B P Housing material 65 x 250mm Cover SUS304 Case SUS304
For transfer load of 1kg Positioning time (sec) Positioning distance (mm) 100 200 50 10 1 50 2.1 4.1 1.1 0.3 0.1 Speed (mm/s) 100 1.1 2.1 0.6 0.2 0.1 200 0.6 1.1 0.3 0.1 0.1 Refer to page 302 for acceleration time. 249 Series LXP CE Marking Guide Rod Type With Motor Brake/Without Motor Brake How to Order LX P B 2 S 1 S B 100 F9N Q B CE marking Guide rod type P Actuator configuration Number
m P 0.1 x m + m P D 1.6 x D 5.0 x D 5.0 x m m mv P Pv m > mv P > Pv Determination of allowable load mass & pressure Inclined operation (Refer to page 1548
M3E Y m x g From the results above, Find the value M3Emax when Va = 350 mm/s from Graph (11) b. n = 0.72 1, so the cylinder can be used. n = 1 + 2 + 3A + 3B = 0.07 + 0.19 + 0.37 + 0.09 = 0.72 Judgement [Graph 5] Allowable load mass by stroke 25 [Graph 9] Allowable load mass on guides m 400 100 B 10 Load mass m [kg] Load mass m [kg] C CY3B CY3R 100 CY1S25-Z 1 y, Z = 100 CY1S CY1S 0.1 CY1L
Series ZPT ZPT H-A16 (Male thread) 100 125 ZPT H-B (Female thread) 100 125 Width across flats 60 M16 x 1.5 70 Hexagon width across flats 22 4 x M5 x 0.8 1/8 (Rc, NPT, NPTF) Width across flats 60 4 x M5 x 0.8 70 10 Hexagon width across flats 24 A B 8 A B 40 40 C M12 x 1.75 100 ZPT100H-B16 103 M16 x 1.5 Model A 100 ZPT100H-B12 B 103 B 103 125 ZPT125H-A16 128 Model A 100 ZPT100H-A16 125 ZPT125H-B12
B IDFB4E to 15E A Power cable outlet 0.7 [17 mm] Grommet with membrane Signal cable outlet 0.7 [17 mm] Terminal block (Wire diameter 0.4 [9 to 11mm]) Grommet with membrane Power cable outlet 0.7 [17 mm] IDFB4E to 11E_Terminal block C D A B Terminal block Dimensions Unit: inch [mm] A B C D Model B B 9.0 [230] 2.6 [67] 7.0 [179] 1.3 [32] IDFB4E, 6E, 8E, 11E A Power cable outlet 0.7 [17 mm]
MA B D-F9BAL A 32 to 100 Proper auto switch mounting positions (mm) D-Z7, D-Z8, D-Y5 D-Y6, D-Y7 D-Y7V, D-Y7WV D-Y7BAL B Bore size (mm) D-Z7 D-Z8 D-Y5 D-Y7 D-Y7W B 18 21.5 26.5 31 39 46.5 A 13.5 19 19 21.5 24.5 34.5 32 40 50 63 80 100 B A D-Y6 D-Y7V D-Y7WV Auto switch mounting heights (mm) Bore size (mm) D-Y7BAL SMC MA SMC 32 40 50 63 80 100 33 37.5 43.5 52 62.5 75 Approx.
B F Accumulated pulse output Brown 1 Load ON OFF OUT1 Main circuit Main circuit 4 Black Analog output White A 50 msec 2 + 24 VDC Load DOWN MODE SET U P 3 Blue C 2-G 60 Load is an analog input equipment such as a voltmeter, ammeter.
Real-time switch output Hysteresis mode ON Flow rate conversion YES OFF P-1 P-2 Normal condition {0C, 101.3 kPa, Dry air} or standard condition (ANR) {20C, 101.3 kPa, 65% RH} can be selected.
Power supply 24 VDC B B B Ground with a ground resistance of 100 or less without connecting the DC1 () lead (Blue) of the power supply cable to the power supply 0 V. Red A A +24 V Black Blue Charged object Charged object 0 V Reduced-wiring Fieldbus System F.G. (mm) Ground with a ground resistance of 100 or less. A B When using the autobalance sensor (body-mounting type) 10 20 20 40 3.
(Values at the initial period) Note 3) At rated voltage Flow Characteristics/Weight Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Weight Valve model Grommet C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT317 VT317V (Vacuum spec. type) VT317E (Continuous duty type) 0.29 kg 2.4 0.26 0.62 2.6 0.34 0.67 2.8 0.25 0.67 2.5 0.37 0.66
P.24 P.36 P.43 32 point I/O unit Wired to PLC I/O card via connection cable and wires connecting equipment to the terminal blocks. 32 point output reduced common unit Wired to PLC I/O card via connection cable and wires connecting equipment to the terminal blocks.
Size/Standard stroke (mm) Rotating angle 32 40 5, 10, 15, 20, 25, 30, 40, 50, 75, 100 A B 80 to 100 170 to 190 Refer to pages 11-10-18 to 11-10-19 for middle and long strokes other than standard stroke.
P #Vacuum Ejector or Pump and Number of Vacuum Pads Ejector and number of pads Vacuum pump and number of pads Vacuum line Tank P P P P P P P P P Ideally, one pad should be used for each line. When more than one pad is attached to a single vacuum line, take the countermeasures listed below.
2 4(A) SYA w (B) 2 (A) 4 (A) 4 (B) 2 w y SYJA 1 (P) (EB)3 5(EA) VFA3000 VFA5000 VZA t (A)4 2(B) 3 (EB) 5 (EA) 1 (P) 5 (EA) 3 (EB) 1 (P) VFA VFA r y 1 (P) (EA)5 3(EB) VFRA 2 position double VPA4 Symbol 2 position double SYJA r t q q VFA1000 (B)2 4(A) w w (A) 4 (B) 2 (A) 4 (B) 2 VZA 5(EA) 1 (P) (EB)3 VTA VFA3000 VFA5000 2(B) (A)4 VGA 3 (EB) 5 (EA) 1 (P) 1 (P) 5 (EA) 3 (EB) t r (EA)5 1 (P) 3
Model PSE30 Set (differential) pressure range 50 to 500 kPa 0.2 to 2 kPa 0.1 to 1 MPa 10 to 100 kPa 10 to 101 kPa 101 to 101 kPa Pressure range Note 1) For positive pressure For low pressure For vacuum For compound pressure For low difference pressure Rated (differential) pressure range 0 to 500 kPa 0 to 100 kPa 0 to 1 MPa 0 to 101 kPa 100 to 100 kPa 0 to 2 kPa 12 to 24 VDC, Ripple (p-p)
For critical applications use A at 2 PSI P . A 10 PSI P will save money and mounting space. Method 2: Chart Index Cv against Bore Size vs. Inches of stroke per second. Assuming 80 PSI and P = 80%.
For critical applications use A at 2 PSI P . A 10 PSI P will save money and mounting space. Method 2: Chart Index Cv against Bore Size vs. Inches of stroke per second. Assuming 80 PSI and P = 80%.