SMC Corporation of America
Elite Part Number Search
Search Results "CDNGBN32TN-200-D-M9PWSDPC-C"

ZA A B t 2 x D ZX C ZM ZL ZH ZH ZH ZH -X267 ZH13 to 20DA 2 x D B ZHP A F E C ZU VQD-V Long clamping screw set for 1 station required for assembly needs to be ordered separately.

cable O.D. 6 to 8 (D, DL) Pilot port B (Air operated) L (Terminal with indicator light: DL) M (Conduit terminal: T) K (DIN terminal: D) I (Grommet: G) J (Conduit: C) 4 x 2-18 mounting hole Applicable flange Pilot port Rc A B C D E F G H I J K L M Model VNB5-32F VNB6-40F VNB7-50F 1 8 1 4 1 4 130 150 180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 100 105 120 36 42 54 12 12 14 244 259.5

ZZ + Stroke Model B C D E(h8) I K L NA Q x R S TC x R W X ZZ REA50 REA63 0 86 32 53 30-0.033 32-0.039 58.2 25 110 55 M8 x 1.25 x 16 176 M12 x 1.25 x 7.5 60 60 180 100 38 66 72.2 26 122 69 0 M10 x 1.5 x 16 188 M14 x 1.5 x 11.5 70 70 192 Mounting nuts/2pcs. packaged with each cylinder d C H d B C Part No.

Note) 200 V type only. 400 V type is provided with an earth leakage breaker as standard. 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 40 3-phase 380 to 415 VAC (50/60 Hz) HRZ Specifications HRZD Model HRS090-Wl-20-l HRS090-Wl-40-l Cooling method Water-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.15 Control method PID control Ambient temperature1 C 5 to

Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com c B part e f d 2.

ULUL1310Class2 6.2 2) AWG20(0.5mm (24V0V) 60 2) EMG AWG20(0.5mm (EMG+,EMG-) 60 8mm 21 - D (100) D 6.3 (CN2SW)ON (EMG+,EMG-) (LEC)EMG (CN2SW) RY CN4 CN2 EMG+ EMG24V 0V (CN2SW)ON EMG+,EMG-(LEC)OFF (LEC)(EMG+,EMG-) 22 - (LEC) ()LEC6 DC24V 0V Ry EMG+ Ry EMG(1 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (2 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (3 ) BK RLS EMG Ry C 24V 24V M

(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)

(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)

Stainless Steel (mm) A B C D E F G H J L Bracket part no.

50/60 Hz 9 Other Option How to Order Pilot Valve Assembly External pilot 00 VT3113 G 1 Coil rated voltage Electrical entry 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz G Grommet Conduit terminal DIN terminal TL D T Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot. 4 Conduit terminal with indicator light TS Conduit

(per unit) Applicable model A B C D HRSE012-AHRSE018-AHRSE024-A240 (335) 505 (540) HRW HRS-TK003 HECR HRSE012-A--T HRSE018-A--T HRSE024-A--T 240 (335) 555 (590) HEC HEB HED HEA IDH Anchor bolt (M8) D C (Prepared by user) Anti-quake bracket Material: Zinc steel plate Mounting view A B w Bypass Piping Set Note) To be mounted by user.

wire length 0.6 m Nil Grommet type Lead wire length 3 m L NPN open collector, double output Analog, no output, 200 degree setting 17 Lead wire length 0.6 m C Connector type Lead wire length 3 m CL NPN open collector, single output Analog, with output, 3 turn setting 18 Without connector CN NPN open collector, single output Analog, with output, 200 degree setting 19 With connector/How to

C 45 P.C.D. C 2 x M depth ML 11.6 P depth PL Air supply port 4 x M depth ML 4 x M depth ML 16.5 16.5 16.5 D D D XT661-10A-(R, L) XT661-8A-(R, L) P depth PL Air supply port P depth PL Air supply port 45 45 45 45 P.C.D. C P.C.D. C 4 x M depth ML 4 x M depth ML 16.5 16.5 D D ZP3 (mm) ZP3E Part no.

Auto Switch Specifications Grommet PLC: Abbreviation for Programmable Logic Controller D-F9W/D-F9WV (with indicator light) D-F9PW D-F9PWV D-F9BW D-F9BWV D-F9NW D-F9NWV Auto switch part no.

D-J51: 5ms or less MHZ2 Lead Wire Length MHZJ2 How to specify lead wire length MHQ (Example) MHL2 L D-A73 MHR Lead wire length 0.5m 3m L 5m Z N MHK MHS None Applicable to only connector type switch D-C MHC2 Note 1) Lead wire length Z: 5m Applicable to Reed switch: D-B53/B54, D-C73 (C)/C80C, D-A73 (C) (H)/A80C MHT2 Solid state switch: Made to order (Except D-F9, F9lV, F7lWV) D-A53/A54, D-Z73

) 51 (61) 55 (65) 59 (69) 63 (73) -XC34 C(D)UK10-D 60 (85) 66 (96) 72 (102) 78 (108) 84 (114) 90 (120) C(D)UK16-D 113 (147) 124 (164) 136 (176) 148 (188) 160 (200) 172 (211) 195 (235) 219 (260) C(D)UK20-D Precautions 212 (266) 229 (288) 246 (305) 263 (322) 280 (339) 297 (356) 335 (390) 370 (424) C(D)UK25-D Be sure to read before handling.

wire length 0.6m Nil Grommet type Lead wire length 3m L NPN open collector, double output Analog, no output, 200 degree setting 17 Lead wire length 0.6m C Connector type Lead wire length 3m CL NPN open collector, single output Analog, with output, 3 turn setting 18 Without connector CN NPN open collector, single output Analog, with output, 200 degree setting 19 With connector/How to Order

C C A B D A A B D B D Dimensions Dimensions Dimensions (mm) (mm) (mm) A B C D E F Y A B C D E F G Y A B C D E F Y Model Model Model ZP40HB ZP63HB ZP100HB 40 41.4 28.4 43.2 20.5 30 13 63 65.1 45.5 67.6 31.5 50 4.5 21.5 100 103.1 68.6 106.7 47.5 80 35.5 ZP50HB ZP80HB ZP125HB 50 51.9 35.7 54 24 40.5 16.5 80 83 58.4 85.1 37 64 5 27.5 125 128.5 88.6 135 56 44 105 13-11-95 Series ZPT/ZPR Replacement

D side parallelism to B side C side parallelism to A side C Dimensions D 2-M23 (Cross recessed head machine screw for precision instrument) M B W Port A Distance from 0 of gauge dial when guide block is moved full stroke after body is fixed on basic bases.