SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2WB80TN-75-D"

Technical Data 1219 MY1H Series Auto Switch Mounting Auto Switch Proper Mounting Position Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AV Auto switch model D-A9 D-A9V A A Bore size A A 25 32 40 81 85 112.5 116.5 133.5 137.5 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.

S: B Throo h hole standard A Both ends ta d L Foot mount F Rod side Iia e Head side flan e Type of Auto Switch , No auto SWitch built in (high magnetic Bore Size D Clevis mount . ~ field resIstance ma net 50 50mm P7G 0P10 63 63mrn l'l14C D-P74 80 80mm i P7 D-P75 Cylinder Stroke D-PS P8!

D-DN This catalog is printed on recycled paper with concern for the global environment.

2 (On different faces or same face) 15 130 125 120 95 70 25 75 D-F5NTL 1 10 D-F5W D-J59W D-F5BAL D-F5F D-F5LF 2 (On different faces or same face) 15 130 125 120 90 70 25 75 10 1 1.12-14

A B C D E F G H J Bracket dimensions Bracket part no. Pressure gauge port size Port size Model AR425/435 AR625/635 AR825/835 AR925/935 80 98 126 160 145.5 155 216 241 3 7 5 10 1/4 1/4 1/4 1/4 1/4, 3/8, 1/2 3/4, 1 1 , 1 2 39.5 43 75 90 46.5 85 48 52 80 90 B24P B25P 67 78 110 140 73 78.5 94.5 4 1 2 1 109.5 464 SP093-001I Issued: Sep 2009 P.G.

A: Acceleration time B: Constant velocity time C: Deceleration time D: Resting time (0.4sec.)

8.50 3/4 NPT .75 5.13 1.31 1.32 3.25 4.25 3.000 1.63 9.00 Note: Pivot and cotter pins are included.

(mm) Model Order no. d: Thread nominal size H B C JS10-4-070 JS16-5-080 JS20-8-125 JS32-10-125 JS40-14-150 JS63-18-150 M40.7 3.2 8.1 DA00127 7 M50.8 4 9.2 DA00128 8 d M81.25 5 15 DA00036 13 M101.25 6 19.6 DA06 17 C M141.5 8 25.4 DA00186 22 M181.5 11 31.2 DA00188 27 H B D-X Technical Data 1157 JS Series Dimensions JS10, 16 M M Center of sphere U D J U F B C E G P H A R Use the precision spanner

V 10 100 10 10 10 1013 VBA Series Sizing ( ) Please use the Booster Regulator Model Selection Software on the SMC website, http://mssc.smcworld.com/brmss/ Tc Ts Pressure Stroke P2 P3 P1 L D Upper limit of pressure inside the tank P3 Necessary supply pressure to cylinder P2 Lower limit of pressure inside the tank P2 Inlet pressure P1 START Time Example Necessary conditions: D [mm]: Cylinder

System construction status No.0 No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 End EX600 EX600 EX600 EX600 EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -SEN3 plate -LAB1 -LAB1 -LBB1 -LBB1 -127No.EX-OMX1011 (6) When unit diagnostics is generated, the diagnostic information is displayed on the [SYSTEM CONFIGURATION STATUS] screen.

-Check the piping, and stop Large air consumption the leakage. 75-Air is leaking from the positioner. -Replace the pilot valve unit. (due to a seating failure of the pilot valve. ) 75-Others. -Contact SMC representatives. Automatic calibration -The angle of the feedback lever is -Refer to 2.

B IDFB4E to 15E A Power cable outlet 0.7 [17 mm] Grommet with membrane Signal cable outlet 0.7 [17 mm] Terminal block (Wire diameter 0.4 [9 to 11mm]) Grommet with membrane Power cable outlet 0.7 [17 mm] IDFB4E to 11E_Terminal block C D A B Terminal block Dimensions Unit: inch [mm] A B C D Model B B 9.0 [230] 2.6 [67] 7.0 [179] 1.3 [32] IDFB4E, 6E, 8E, 11E A Power cable outlet 0.7 [17 mm]

5 7 8 7 10 13 17 22 27 14.4 19 24.8 29 38.4 49.2 17 23 29.9 33.5 38 47.5 80 210 JS20-8-125 JS32-10-125 M8 x 1.25 M10 x 1.25 43.9 49.5 1100 2500 6000 11000 JS40-14-150 JS63-18-150 M14 x 1.5 M18 x 1.5 60 74.5 11 13.5 Rod end nut (mm) d: Thread nominal size 30 Description H B C D d JS10 nut M4 x 0.7 3.2 7 8.1 6.8 JS16 nut M5 x 0.8 4 8 9.2 7.8 JS20 nut M8 x 1.25 5 13 15 12.5 D C JS32 nut M10

d: Thread nominal size M20 x 1.5 M20 x 2.5 M22 x 1.5 M24 x 1.5 M24 x 2 M24 x 3 M26 x 1.5 M27 x 1.5 M27 x 2 M30 x 1.5 M30 x 2 M33 x 2 M36 x 1.5 M39 x 1.5 M42 x 3 M48 x 1.5 D C B B H H C D CE1 29 29 31 34 34 34 39 39 39 44 44 48 53 57 62 72 34.6 34.6 37 41.6 41.6 41.6 47.3 47.3 47.3 53.1 53.1 57.7 63.5 69.3 75 86.5 30 30 32 36 36 36 41 41 41 46 46 50 55 60 65 75 5.5 7 8 10 13 13 17 17 17 19

Additionally multiple components maybe added at D. (Example: Timer and Push Button combination for an automatic return or manual return.)

Additionally multiple components maybe added at D. (Example: Timer and Push Button combination for an automatic return or manual return.)

D/MS3102A20-15S Connect the DC cable connector of the heat exchanger. 6 Contact b for upper/lower temp. limit alarm (closed when alarm occurs) A F Alarm output connector D-sub 9 pin (pin type) 7-9 Unused G E B 6. Communication connector: D-sub 9 pin OMRON Corp. XM2D-0901 or equivalent, holding screw M2.6 Connection cable: With shielding 22AWG or more Pin No.

A: Acceleration time B: Constant velocity time C: Deceleration time D: Resting time (0.4sec.)

50.1 50.1 MXQ16B 20.6 20.6 20.6 20.6 20.6 20.6 20.6 20.6 20.6 33 23 23 23 29 38 63 63 63 MXQ20B 32.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2 30.9 31.9 31.9 31.9 44.9 44.9 46.9 69.9 69.9 D-M9V/M9WV A 10 20 30 40 50 75 100 125 150 10 20 30 40 50 75 100 125 150 MXQ6(A) 18 7.4 7.4 7.4 7.4 2 2.6 5.6 7.6 7.6 MXQ8(A,C) 13.9 13.9 13.9 13.9 13.9 13.9 7.1 7.1 7.1 13.1 30.1 7.1 MXQ12(A,C) 16.5 16.5