OUTLET INLET Mounting hole Top view (Mounting hole on bottom) Porting Symbols OUTLET (Downstream) INLET (Upstream) 2PW 2PWA 2PWC q q q w 2 PORTS w w 3PWD 3PWE 3PWG 3 PORTS q q q e e e w w w 4PWM q e r 4 PORTS w 1114 A
Port size For sub-plate, manifold type 40, 41, 42, 43 Nil: Without sub-plate R port P, E port 3: Common exhaust type for main and pilot valve D: Push-turn locking slotted type R port P, E port (With gasket and screws) 01: 1/8 With sub-plate Electrical entry 24, 12, 6, 5, 3 VDC M8 connector 24, 12, 6, 5, 3 VDC 100,110, 200, 220 VAC 24,12 VDC 100,110, 200, 220 VAC Grommet L plug connector M
1 1-1/4 1-1/2 2 Maximum Rated Pressure (PSI) 5000 5000 5000 5000 4000 4000 4000 3000 Except the following port options in the noted size 03 (Male JIC 37) 3000 2000 05 (Male SAE O-Ring Boss) 2500 06 (Female JIC 37) 90 Housing Port 4000 3000 3000 2500 2000 06 (Female JIC 37) In-Line Housing Port 3000 2000 07 (Female NPSM) 4600 3000 2600 2100 1650 1500 Temperature Range (std seals) -40 to 250
E 21 S LQ1 LQ1 fittings Nut (including insert bushing), 1 location removed Fitting type E Union elbow T Union tee Applicable tube size Metric Inch Applicable tube size (mm) Applicable tube (inch) Reducing Reducing Size No.
Ordering Example of Cylinder Assembly Double clevis Cylinder model: CDJ2YD16-60Z-NW-M9BW-B Double knuckle joint Mounting D: Double clevis Pivot bracket N: Yes Rod end bracket W: Double knuckle joint Auto switch D-M9BW: 2 pcs.
Power supply connector Cable Qty. x size 3cores14AWG 3cores2.0mm2 *including ground N E(Earth) L Fig 3-3 Cable connection 5. Insert the power supply connector to the power supply connector socket. 6.
The table e is moved based on the user defined settings. -Necessary settings: Target position, speed, acceleration, deceleration and load mass.
MVAny MVtype Valve will work here, set up Normally Open E SCS-112 1/8 Stroke Completion Sensor (SCS) SCS-250 SCS SCS-375 3/8 SCS SCS-500 SCS www.poweraire.com 1-800-526-7661 22 Section III: Circuits Two Hand Extend Two Hand Retract Use this circuit, where a pinch point exists on both the extension and retraction of the linear actuator.
MVAny MVtype Valve will work here, set up Normally Open E SCS-112 1/8 Stroke Completion Sensor (SCS) SCS-250 SCS SCS-375 3/8 SCS SCS-500 SCS www.poweraire.com 1-800-526-7661 22 Section III: Circuits Two Hand Extend Two Hand Retract Use this circuit, where a pinch point exists on both the extension and retraction of the linear actuator.
Panel mount E Lead wire length 3 m L Panel mount + Front protection cover F Analog Output Suitable model: ZSE50F/ISE50--22/62(L)-(M) Series ISE50 Series ZSE50F Analog output value (V) Analog output value (V) Unit specification 5 5 Note 1) Nil M With unit switching function Note 2) Fixed SI unit 1 1 Note 1) Under the New Measurement Law, which has been in effect since October, 1999, sales
0.4 340 10 4.5 6 8 250 1.0 3 8 (10A) 340 0.4 10 10 1 2 (15A) 420 Note) Refer to Glossary on page 17-3-15 for details of max. operating pressure differential and max. system pressure.
, 300, 350, 400, 450, 500 Replacement Parts: Seal Kits 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit No. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.
B C Nil None With SUP blocking plate With EXH blocking plate With SUP and EXH blocking plates Port plug A Port plug B 1 2 3 Note) P R PR A B Cylinder port size 4 Note) 5 Note) E Note) The 3 position type uses two stations.
kbps 0 1 1 2 500 kbps 0 2 2 3 : : : : PGM 6 2 62 9 6 3 63 6 4 : : PGM 9 DeviceNetPGMHW/SW ON -21No.EX-OMN0029CN-D V_SEL SI () Settings1 SI 1 2 OFF OFF 32 4 byte() OFF ON 24 3 byte ON OFF 16 2 byte ON ON 8 1 byte Baud Rate EX600 Settings1 3 4 OFF OFF 1 Mbps() OFF ON 500 kbps ON OFF 250 kbps ON ON 125 kbps 1 Mbps() -22No.EX-OMN0029CN-D Settings2 1 2 OFF OFF 0 () 0 byte OFF ON
TUB-20 Series PEAPP Series PEAPP Polyurethane Tubing How to Order PEAPP 07 BU 153 Linear low density polyethykene tubing, Industrial grade Length per roll Length 100 (33m) 250 (100m) 500 (153m) 1000 (305m) Symbol 33 100 153 305 Tube O.D.
Turn power off and then on again. 1.6 Over current 500 ms 500 ms 0 1.0 5.0 1.3 1.2 Input signal Voltage [V] Flashing: Two ashing cycles of 250 ms at two-second intervals Error automatically resets when the supply ow rate is recovered (LED goes off). Insufcient supply ow rate Flow rate control Position control (Fully closed) 250 ms 250 ms 2000 ms 1 A
C D A B Side support B MY-SB 2 x J MY1B MY1B MY1H E A B MY1B C D MY1M (mm) MY1C A 61 70 87 B C D E F G H J Part no.
229 16 L n 12 273 262.5 239.5 17 10 235.5 225 208 14 11 248 237.5 218.5 15 13 273 262.5 239.5 17 14 285.5 275 250 18 15 285.5 275 260.5 12.5 16 298 287.5 271 13.5 10 248 237.5 218.5 15 11 260.5 250 229 16 13 285.5 275 250 18 14 285.5 275 260.5 12.5 15 298 287.5 271 13.5 16 310.5 300 281.5 14.5 L1 L2 L3 L4 L1 L2 L3 L4 33 3 Station table entries In the case of a standard type manifold, solenoid
Description Material Body Cap 1 2 3 4 5 6 7 8 12 Aluminum alloy Rolled steel Steel wire Stainless steel Zinc alloy Steel wire Zinc alloy Aluminum alloy NBR Cross-recessed head cap screw E type snap ring Handle Ring Lock nut Needle O-ring Replacement Parts No. Description Material Parts no.