Installation at indoor site 1 In case of facility having a large installation area (that can vent the air naturally) Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2 In case of facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
Through the use of a booster, a pressure that is higher than that of the main air passage can be supplied.
, HNBR 9 Body Aluminum die-casted 799 IR1000-A/2000-A/3000-A Series Construction Basic type (Knob): IR10l0-A r r r r q w e OUT side passage IN side passage y u t OUT IN i o Basic type (Knob): IR30l0-A e e r q r w e OUT side passage IN side passage t u OUT IN o i Basic type (Knob): IR30l1 2-A e e r q r w e OUT side passage IN side passage t u OUT IN o i 800 Precision Regulator IR1000-A/2000
, HNBR 9 Body Aluminum die-casted 781 IR1200-A/2200-A/3200-A Series Construction Basic type (Knob): IR12l0-A r r r r q w e OUT side passage IN side passage y u t OUT IN i o Basic type (Knob): IR32l0-A e e r q r w e OUT side passage IN side passage t u OUT IN o i Basic type (Knob): IR32l1 2-A e e r q r w e OUT side passage IN side passage t u OUT IN o i 782 Regulator IR1200-A/2200-A/3200-A
Note 2) Valve type R cannot use a pressure switch for vacuum with energy saving function.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
If the leakage volume is 5 /min (ANR), the vacuum pressure of the S type is 80 kPa r t y, and for the L type it is 47 kPa r' t' y'. Thus, if the leakage volume is 30 /min (ANR) the L type can attain a higher vacuum pressure, and if the leakage volume is 5 /min (ANR), the S type can attain a higher vacuum pressure.
For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
O. () ) 22240psi (0.15 ~ 1.6MPa) 3/h(ANR)] ) 1.77SCFM(ANR)[3m 8-4 8-3 (ADH4000-04) IDFB Series 8-2 IDX-OM-W035 9 R 9 R 9-1 9-2 IDFB22E-11-R 15A 30mA IDFB22E/37E-23-R IDFB55E/75E-46-R 10A 30mA 9-3 (IDFB55E,75E) (IDFB55E,75E) 9-1 IDFB Series 9-1 IDX-OM-W035 9 R IDFB22E/37E 0.37inch (9.5mm) L N () PE () 0.26inch (6.5mm) IDFB55E/75E 0.4inch (10mm) 0.4inch (10mm) L1 L2 L3
IDX-OM-W034-B PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFB22E-11 IDFB22E-11 K,R,S,T,V IDFB22E-23 IDFB22E-23 K,R,T,V IDFB37E-23 IDFB37E-23 K,R,T,V IDFB55E-46 IDFB55E-46 L,R,T,V IDFB75E-46 IDFB75E-46 L,R,T,V This manual is intended to explain the installation and operation of the product.
Applicable model t ZH15DA-09-N03-11 ZH15DA-N02-N03-N03 2 Minimum C Factor of a Supply Valve Model C[dm3/(sbar)] ZH05A 0.12 ZH07A 0.23 ZH10A 0.47 ZH13A 0.80 ZH15A 1.06 ZH18A 1.53 ZH20A 1.88 ZH18DA-11-N03-13 ZH18DA-N03-N03-N03 1 ZH20DA-10-04-12 ZH20DA-03-04-04 ZH20DA-11-N04-13 ZH20DA-N03-N04-N04 t 2.
7 r !3 o r !0 w u t y !2 !3 !1 q i !4 e Meter-in type Meter-in type AS ASP ASN AQ ASV AK ASS ASR ASF Component Parts: Elbow Type Component Parts: Universal Type No. Description Material Note Body A Handle Body B Needle Gasket Seat ring Lock nut U seal Cassette Seal O-ring O-ring O-ring No.
2 Port for Steam Dimensions (mm) 1in = 25.4mm Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G (PF) 1/2 C R R E E B A H 2-P Port size 2-P A B H 2-M Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.
2 Port for Oil Dimensions (mm) (N.C.) 1in = 25.4mm Grommet: G Conduit: C Approx. 300 V D Approx. 280 D F Approx. 300 F Q Q Class H coil Broken line section C C G 1/2 R R E E A H A H B B 2-P Port size 2-P Port size 2-M, thread depth N 2-M, thread depth N L L K K DIN terminal: D Conduit terminal: T Cable 6.8 to 10 F S Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port
Model number Serial number Type and quantity of refrigerant How to read the serial number A R 001 April 2022 A R 001 Year Symbol Remarks Month Symbol Remarks Serial no. 4 R Repeated from O to Z in alphabetical order, with O for January and Z for December 2022 A 2023 B 5 S Repeat ed from A to Zin alphab etical order 2024 C 6 T Fig 1-1 Position of product label HRR Series 1.4 Product Label
Check using a feeler gauge that the clearance between the position indicator (109) and the electronics cover is 1 mm. 7 ND90 71 en 17 N O I T A C O L S U O D R A Z A H N O I T A C O L S U O D R A Z A H N O N ND9000H Valve Positioner Position Transmitter X300 Ui (Vmax) = 28 V Ii (Imax) = 120 mA Pi (Pmax) = 1 W Li = 53 uH Ci = 22 nF Ex i Barrier + 1 Uo (Voc) 28 V Io (Isc) 120 mA Po 1 W
Thread R(PT) Port B min. port size Weight (g) D2 L1 L2 L3 P A Q1 Q2 M1 M2 1 8 1 4 3 8 6 4 KM14-04-06-01S-3 13 14 17 18 13 10.4 38.2 16 9.9 17 68 71.5 73.5 19 26 39 4.5 KM14-04-06-02S-3 12.8 10.4 KM14-04-06-03S-3 64 65.5 67.5 1 8 1 4 3 8 8 4 KM14-04-08-01S-3 31 69.5 70.5 71 73.5 76.5 77.5 17 19 15.5 10.4 38.2 16 11.1 18.5 39 6 KM14-04-08-02S-3 15.2 10.4 KM14-04-08-03S-3 1 8 1 4 3 8 8 6 KM14
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be as follows.