1 to 12 stations Side 1 to 12 stations 26P P kit: Flat ribbon cable 420 20 20P 1 to 9 stations C8 (For 8) 10-SS5Q13-10-SQ131 J kit: Flat ribbon cable PC wiring system compatible L3 (For 3.2) L4 (For 4) L6 (For 6) L5 (M5 thread) 1 to 8 stations 420 20 Top Note 2) 1 to 12 stations L kit: Lead wire 460 35 1 to 8 stations 475 20 S kit: Serial transmission Note 1) One-touch fittings in inch sizes
Example) 4-20 mA 20-4 mA 0-10 V 10-0 V : If teaching is performed with the conditions below, the setting might be interrupted and the orange LED flashes 4 times. If teaching is performed at the start or end of the measuring range, magnet force is not detected. Minimum set measuring range: 1 mm -14No.D-S-OMU0002-A Switch output mode There are 4 modes for switch output.
Note) The min. bending radius of D-sub cable is 20 mm. Insulation resistance Mkm, 20C 5 or less 16 44 8 SMC Connector manufacturers example Fujitsu, Ltd. Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd.
Vacuum supply port 3.3 Gasket 16-6-12 7 Compact Pressure Switch Series ZSE2/ISE2 01 T1 Dimensions: ISE2Grommet type: ISE2-15 01 T1 01 T1 Connector type: ISE2-15C Pressure setting trimmer Pressure setting trimmer L H SET L H SET 15 15 ZSE ISE Indicator light (Red) Indicator light (Red) 20 20 PSE Z I SE3 600 (3000) PS 600 (3000) Z I SE1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way,
I l 50i 70 , iiFl.r* 0 q . . , . 50 6o ' 3 0 3o , , , . 3 0 , : LXPB5SA 40 40 '" .,1 Slide i Screw \ I i LXPB5SB 2D 2A LXSH2BC 100 50 220 High rigidity linear guide Ball LXSH2BD 100 50 90 Screw LXSH5BC 1 0 0 50 1 6 0 LXSH5BD 1 0 0 50 70 LXSH2SA 90 40 60 Slide LXSH2SB 45 20 30 Screw LXSHSSA 60 20 40 LXSH5SB 30 1 0 20 , \ | '-t 'oo"ot| I PLc I ll'i;!:-,?
16 18 20 16 11 13 11 Vacuum supply port 3.3 Gasket Vacuum supply port 3.3 Gasket 784 Compact Pressure Switch Series ZSE2/ISE2 01 T1 Dimensions: ISE2Connector type: ISE2-15C Grommet type: ISE2-15 01 T1 01 T1 Pressure setting trimmer Pressure setting trimmer L H SET L H SET 15 15 Indicator light (Red) Indicator light (Red) 20 20 600 (3000) 600 (3000) ZSE ISE ZSP 48.5 41 39 39 PS 3.5 3.5 ISA
Refer to page 3-13-4.) 20 or less 50 or less 10 3 Refer to the table below.
Note) The min. bending radius of D-sub cable is 20 mm. Insulation resistance Mkm, 20C 5 or less 16 44 8 SMC Connector manufacturers example Fujitsu, Ltd. Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd.
Maximum stations are 18. 16 4 17 5 18 6 19 7 20 8 21 1.
Start flag 0: no send Numerical data input 1 1: send Data writting RWwn Step data No 0 to 63 Operation Note) 1 1: Absolute 2: Relative H RWwn+1 L Speed 2 0 to 65500 mm/s 3 RWwn+2 2 Position 4 +/-2147483647 0.01mm 1 RWwn+3 0 H RWwn+4 L Acceleration 2 0 to 65500 mm/s2 ID1 Numerical data input H RWwn+5 L Deceleration 2 0 to 65500 mm/s2 Data writting Pushing force 1 0 to 30 10% RWwn+6 Trigger
Installation . 20 3.1. Mounting . 20 3.2. Wiring . 21 4. Commissioning . 24 4.1. Configuration . 24 4.2. Diagnostics parameter . 24 4.3. Safe valve power module . 25 4.4. PROFIsafe parameter . 25 4.5. Valves (32coils) module . 26 4.6. 1 Byte feedback information about the valve output status . 26 5. Specifications . 27 6. Indication and setting . 29 6.1. LED indicators . 29 6.2.
input current 147 m/s2 3 times each in directions of X, Y and Z respectively (De-energized) Impact resistance Max. load current 500 mA or less/output For use in Pollution Degree 2 Environment (UL508) Pollution degree Input (left) "0 to 7" green LEDs are On The input device is On.
Installation distance mm Min. installation interval mm Object that is not to be measured Sensor head Charged object 10 20 20 40 Installation distance 25 45 30 55 40 65 50 75 60 90 Min. installation interval 70 100 75 105 Electrostatic sensor is affected by electric field or electromagnetic field due to its operation principle.
(between FE and all accessible terminals) Insulation resistance 10 M or more (500 VDC is given between FE and all accessible terminals) Ambient temperature Operation: -10 C to 50 C Storage: -20 C to 60 C Ambient humidity 35% to 85% RH (non-condensing) 10 Hz to 57 Hz (constant amplitude) 0.75 mm 57 Hz to 150 Hz (constant acceleration) 49 m/s2 2 hours for each direction X, Y and Z Vibration
Applicable bore Shock absorber model ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 101 90 25 20 11 72 67.3 12 31 39.5 Max. 16.5 4.5 3 RB1412 120 107 30 25 16 93 73.2 15 38 49 Max. 20 5.5 6 RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 Max. 25 5.5 6 Side Support Side support A 2 x G E E F 2 x H A B Side support B 2 x J A B (mm) A B C D E F G H J Part no.
P10 P10F Max. 0.7 x 20 O-ring 4 Hexagon socket head screw 2 Option Description Part no.
(Refer to Precautions on page 16-2-24 for details.) 1.5 01: R 1/8 T1: NPT 1/8 Data ZSE40(F)/ISE40-W1 2-M4 x 0.7 thread depth 4 20 30 Rc 1/8 MPa 7 19 20 30 OUT2 OUT1 SET 6.5 R 6.4 18.35 Atmospheric release port Lead wire length 600 (3000) 3.5 12.4 7.8 7 2.5 2.6 30 15.2 42 10.7 4 6 For splash proof use (IP65), insert an air tube into the atmospheric release port.
to 9800mm/s2 Note) Note) There are cases in which the position, speed and acceleration designations are not realized, depending on the actuator that is connected and the operating conditions.
Specications [mm] Table 1 Cylinder Strokes Bore size Stroke 16 15, 20, 25, 30 20, 25 15, 20, 25, 30, 35, 40, 45, 50 32 to 63 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Ambient and uid temperature range 32 to 302F [0 to 150C] Seal material Fluororubber Grease Heat resistant grease Standard stroke See Table 1. Dimensions See below.
P (Port size) Operation P (Port size) Model CYV15 CYV32 Caution 5/16-24 UNF 7/16-20 UNF 1. The maximum operating pressure for the vacuum rodless cylinder is 0.3 MPa.