SMC Corporation of America
Elite Part Number Search
Search Results "25A-MXQ20-20C"

(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) When operating the locking type manually, apply torque of 0.2 Nm or less. Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) When operating the locking type manually, apply torque of 0.2 Nm or less. Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

Linearity 3% F .S. or less AMR Lubrication Not required (Use turbine oil Class 1, ISO VG32, if lubricated.) 0.9 0.9 1.0 1.4 1.4 Weight (kg) ITV Proportional Solenoid Specifications IC 1 (Applicable power amplifier: VEA25) Proportional solenoid recognition symbol VEA25 VBA Applicable power amplifier VEF3121 (Flow type) VEP3121 (Pressure type) Max. current 1 A VE Coil resistance 13 (20C) Rated

The value of the max. operating pressure is at a temperature of 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube.

Note 2) The above data is based on a room temperature of 20C. Note that you may obtain different figures, depending on temperature conditions. Note 3) The above data shows compatibility guidelines based upon component parts. Therefore, it is no guarantee of product performance.

Inch size 1/4" 1/8" 5/32" Flow rate (l/min(ANR)) 170 100 120 150 IN OUT Effective area (mm2) 2.6 1.5 1.8 2.3 IN P1 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20C.

Note) Insulation resistance M/km, 20C For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308. The minimum bending radius of D-sub cable assembly is 20 mm. 5 or less Positive common specifications Negative common specifications As the standard electrical wiring specifications, double wiring (connected to SOL. A and SOL.

Note 2) When mounted on a heat dissipating base at an ambient temperature of 68F (20C). Note 3) The pushing force varies depending on the operating environment, pushing direction and table position. Refer to Pushing force characteristics (Front matter 4). Note 4) When the temperature of the Card Motor is 68F (20C).

(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) When operating the locking type manually, apply torque of 0.2 Nm or less. Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

ANR: 20C atmospheric pressure, relative humidity 65% 200 300 , 0.2 AMC-EL3 BE30 1,000 1 4 3 8 1 4 , 3 4 1 2 0.12 AMC-EL2 BE20 0.5 AMC-EL5 BE50 5-10-11

Correction Factor by Ambient Temperature Mounting Caution (Example) Inlet air temperature: 100C, Ambient temperature: 20C, Amount of air: 2000 l/min (ANR), Air pressure: 0.7 MPa, Model: HAA22-14 Outlet Air Temperature at Above Conditions Use outlet air temperature of 38.5C from outlet air temperature table. At this time correction factor line becomes . 1.

(Example) Inlet air temperature: 100C, Cooling water temperature: 20C, Cooling water flow: 17 l/min Air flow: 2000 l/min (ANR), Air pressure: 0.7 MPa, Model: HAW22-14 Outlet air temperature at above conditions Use outlet air temperature of 37C from outlet air temperature table. At this time correction factor line becomes .

: 32C, w Circulating uid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 200 VAC 4 q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: CH1 20C/CH2 25C, r Load: Same as the cooling capacity, t Circulating uid ow rate: Rated ow, y Power supply: 200 VAC, u Piping length: Shortest 5 With the pressure control mode by inverter.

5) q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: 20C, r Load: Same as the cooling capacity, t Circulating uid ow rate: Rated ow, y Power supply: 200 VAC, u Piping length: Shortest Note 6) When circulating uid outlet port pressure return port pressure = 0.25 MPa.

Note 5) The capacity at the thermo-chiller outlet when the circulating uid temperature is 20C. Note 6) Required ow rate for cooling capacity or maintaining the temperature stability. The specication of the cooling capacity and the temperature stability may not be satised if the ow rate is lower than the rated ow.

Accessories Weight10 [kg] 45 1 It should have no condensation. 2 If tap water is used, use water that conforms to Water Quality Standards of the Japan Refrigeration and Air Conditioning Industry Association (JRA GL-02-1994 cooling water system circulating type make-up water). 3 q Ambient temperature: 25C, w Circulating uid temperature: 20C, e Circulating uid rated ow, r Circulating uid: Tap

Note 4) The capacity at the circulating fluid outlet when the circulating fluid temperature is 68F (20C). Pump capacity at 60 Hz indicates the maximum capacity of the HRWlll-HS (pump inverter type). Note 5) Applicable to the HRWlll-HS (pump inverter type) only. Note 6) Minimum volume required for operating only the Thermo-chiller.

Contacts/Bulb gland Pressure Source Nil W Nil B C 1a1b (Standard) 2ab Contact Warning Enclosure Type A 20a (Standard) Type A 20b Type A 20c Bulb gland 1.

FR one-touch fittings: Series KR-W2 Metal one-touch fittings: Series KQB2 Applicable fittings 0.8 MPa At 20C Max. operating pressure 0.65 MPa At 40C How to measure the minimum bending radius 0.5 MPa At 60C Burst pressure Refer to the burst pressure characteristics curve.

Weight (kg) 0.9 Note) The non-lubricated specification is not applicable to these models. 0.9 1.0 1.4 1.4 Proportional Solenoid Specifications VEF3121 (Flow type) VEP3121 (Pressure type) 1 (Applicable power amplifier: VEA25 ) Proportional solenoid recognition symbol Applicable power amplifier VEA25 Max. current 1 A Coil resistance 13 (Ambient temperature 20C) Rated power consumption 13 W