Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ How to Order Vacuum Pad Note) Refer to page 1252 for combination of cylinder and pad. In the case of pad direct mounting In the case of rod end male ZPT U N 02 B4 ZP U N 04 X11 Vacuum entry (Mounting thread diameter) Pad dia. (mm) Pad dia. (mm) Thread dia.
Piping tubing length 0.4 0.8 Response time (sec) Response time (sec) Piping tubing length 10 m 0.3 0.6 8 m 8 m 5 m 0.2 0.4 5 m 3 m 3 m 0.1 0.2 1 m 0 0 0.35 0.05 0 0 0.16 0.02 0.3 0.25 0.2 0.15 0.1 0.14 0.12 0.1 0.08 0.06 0.04 Detection distance (mm) Detection distance (mm) Piping tubing lengthResponse time Piping tubing lengthResponse time Nozzle Shape Please keep the nozzle shape as illustrated
t L d m t D d9 D d9 l l Part no.
VT/O317-G(-02) VT/O317-GS(-02) VT/O317-H(-02) VT/O317-HS(-02) VT/O317-C(-02) VT/O317-CS(-02) VT/O317-T(-02) VT/O317-TS(-02) VT/O317-TZ(-02) VT/O317-D(-02) VT/O317-DS(-02) VT/O317-DZ(-02) Coil no. PVT317-001GBPVT317-G PVT317-001GB-L06 PVT317-G-06 PVT317-001CBPVT317-C Coil assembly with terminal part no.
Description Material Note q w e r t y u i o !0 !1 !2 !3 !4 !
1 o w !0 !1 e w r e Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com u r u t t y y q q Component Parts Description Material No. Option Standard Stainless steel Body C37 q w e r t y u i o !0 !
AW-OMS0038-C PRODUCT NAME FILTER REGULATOR MODEL/ Series AW20-(F,N)01(F,N)02(B,C,E,G,H,M)(-1,2,6,C,J,N,R,Z)-B AW30-(F,N)02(F,N)03(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW40-(F,N)02(F,N)04(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW40-(F,N)06(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW60-(F,N)06(F,N)10(B,C,D,E,G,M)(-1,2,6,8,J,N,R,W,Z)-B Contents PAGE 1. SAFETY INSTRUCTIONS 16 2. APPLICATION 7 3.
AW-OMT0013-B PRODUCT NAME FILTER REGULATOR MODEL/ Series AW20K-(F,N)01(F,N)02(B,C,E,G,H,M)(-1,2,6,C,J,N,R,Z)-B AW30K-(F,N)02(F,N)03(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW40K-(F,N)02(F,N)04(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW40K-(F,N)06(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW60K-(F,N)06(F,N)10(B,C,D,E,G,M)(-1,2,6,8,J,N,R,W,Z)-B Contents PAGE 1. SAFETY INSTRUCTIONS 16 2.
How to Order Type 40 1(P) port Stations VV5Z3 05 40 2 M5 Rc 1/8 4(A), 2(B) port size 1(P), 3/5(R) port thread type 02 2 stations 3, 5(R) port M5 M5 x 0.8 Nil Rc 4(A), 2(B) port Rc 1/8 F G 20 20 stations M5 x 0.8 N NPT Z NPTE How to Order Type 41 VV5Z3 05 41 1 M5 Applicable solenoid valve Stations 4(A), 2(B) port size 1(P), 3/5(R) port thread type 3/5(R) port 02 2 stations G L M D G L M
Tubing size (O.D. x I.D.) mm: 12 x 9 IDG30 IDG50 0 m 20 1 m 19 3 m 17 5 m 16 Note) In cases other than above model numbers, if the tube length is 5 m or less, an increase of the outlet air at the atmospheric pressure dew point will be 1C or less. Refer to pages 14-19-28 to 29. Construction Refer to pages 14-19-30 to 31.
VE VY The oil that has been pumped from the tank passes through felt q where it is filtered, and is fed into the case through nozzle w. When the volume of oil in the case reaches a certain level, float e ascends, valve t descends via lever r, nozzle w closes, and the feeding of oil stops, thus completing the oil feeding process.
8 w $4 t e $2 !5 $3 y!7 @8 !4 !
Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air New Series VX21/22/23 Reduction of power consumption Reduction of power consumption (DC specification) (DC specification) 6 W 4.5 W 6 W 4.5 W 8 W 7 W 8 W 7 W 11.5 W 10.5 W 11.5 W 10.5 W Low power consumption type: Low power consumption type: 0.8 W 0.8 W (Held at 24 VDC) VX Series New VX Series now on sale!
i ng W hen t he bracket i s m ount ed t o t he product D i rect m ount i ng Bracket m ount i ng f or m ount i ng i t ont o t he panel or devi ce, f i x t he bracket t o t he product w i t h t he screw s provi ded. ( See t abl e above f or t i ght eni ng t orque) .
How to Order Valve (Applicable to VQZ200/300 rubber seal style only) VQZ332 5YZB 02 W IP65 rated No (standard) (1) IP65 rated W Note 1) The pilot exhaust of the IP65 valves is common with main valve exhaust.
As a guide, adjust P2, so that it could be W + P2A = P0a.
Moving forward Moving backward Actuator 10-17-6 Air-hydro Unit Series CC Hydro Unit Air port size Rc RE A B REC CX CY Lube-plug 4-T Mounting hole MQQ M RHC MK(2) RS Q G Rc 1/8 Pilot air port port (Stop valve side) Rc 1/8 Pilot air port port (Stip valve side) RS H A Manual push button RZQ MI W S CEP1 CE1 CE2 Oil port size Rc Oil draining hole Rc 1/4 Throttle valve locking screw ML2B C J G5
-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rc 1/8 Pilot air port size RHC MK(2) Oil port size Rc RS Q G Throttle valve locking screw RS H A RZQ Oil port size Converter side Oil port size Cylinder side 2-S Wall mounting screw Unit port U1, U2 MI W S CEP1 CE1 CE2 (mm) Model Oil port size Rc A B CA CL GB GL KA KB KL L QA M NB NL QB QL R T GA 18
As a guide, adjust P2, so that it could be W + P2A = P0a.
As a guide, adjust P2, so that it could be W + P2A = P0a.