Symbol Foot (mm) A AL D I B B1 C H1 H W GA GB H2 J KA LC LD LH LS LT LX LZ M MM NA P S X Y Z ZZ Bore size (mm) 20 25 32 40 50 63 80 100 12 20 5 12 14 4 33 10 14.5 34 13 8 6 4 26 M4 x 0.7 6 20 (3) 32 44 3 M8 x 1.25 24 M5 x 0.8 57 15 7 32 83 Width across flats 6 length 3.5 12.5 23 6 15 16.5 4 36 10 17.5 38.5 17 10 7 4 31 M5 x 0.8 6 22 (3) 36 49 3.5 M10 x 1.25 29 M5 x 0.8 60 15 7 35 89.5 Width
Suffix of how to order (@) U2: M-5AU-2,U4: M-5AU-4-X83 U6: M-5AU-6-X83,02: KJH02-M5 04: KJH04-M5, 06: KJH06-M5 ZP3B-T2A(J/K)6-B5 ZP3B-T2A(J/K)10-B5 ZP3B-T2A(JB/K)15-B5 ZP3B-T2A(JB/K)20-B5 Note 1) ; in the table indicates the pad material. Note 2) @ in the table indicates the vacuum inlet. Note 3) Fitting is ordered separately.
Suffix of how to order (@) U2: M-5AU-2,U4: M-5AU-4-X83 U6: M-5AU-6-X83,02: KJH02-M5 04: KJH04-M5, 06: KJH06-M5 ZP3B-T2A(J/K)6-B5 ZP3B-T2A(J/K)10-B5 ZP3B-T2A(JB/K)15-B5 ZP3B-T2A(JB/K)20-B5 Note 1) ; in the table indicates the pad material. Note 2) @ in the table indicates the vacuum inlet. Note 3) Fitting is ordered separately.
Suffix of how to order (@) U2: M-5AU-2,U4: M-5AU-4-X83 U6: M-5AU-6-X83,02: KJH02-M5 04: KJH04-M5, 06: KJH06-M5 ZP3B-T2A(J/K)6-B5 ZP3B-T2A(J/K)10-B5 ZP3B-T2A(JB/K)15-B5 ZP3B-T2A(JB/K)20-B5 Note 1) ; in the table indicates the pad material. Note 2) @ in the table indicates the vacuum inlet. Note 3) Fitting is ordered separately.
x 0.8 Mixed C4 C6 M5 M 1 2 3 4 5 5 6 24VDC 12VDC Match to the voltage specifications of the manifold.
Load voltage Auto switch model Lead wire length (m) 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Wiring (output) Special function Tie-rod mount Pre-wired Type Electrical entry Applicable load 40 to 100 32 40 to 100 32 Band mount AC DC connector None G59 G5P K59 M9N 3-wire (NPN) F59 5 V, 12 V IC circuit M9P Grommet 3-wire (PNP) 24 V F5P M9B 12 V 2-wire J59 Reed auto switch Solid state
Pilot Solenoid Valve Specifications Internal pilot solenoid / External pilot solenoid Model VEX3121, VEX3221, VEX3321, VEX3421 VEX3122, VEX3222, VEX3322, VEX3422 Pilot valve V114, V115 Symbol Electrical entry Grommet (G), L plug connector (L), M plug connector (M), DIN terminal (D) Rated coil voltage [V] AC (50/60 Hz) 100 V, 110 V, 200 V, 220 V DC 3 V, 5 V, 6 V, 12 V, 24 V Allowable voltage
Direction Horizontal, Upward, Downward (Using elbow fittings for upward or downward) C6, C8, N7, N9 (Inch size elbow fitting is not available.) 1(P), 3/5(E) port Port size C2, C4, N1, N3, M3 SJ2000 4(A), 2(B) port C2, C4, C6, N1, N3, N7, M5 SJ3000 Weight W (g) Note 2) W = 51n + m + 133 n: Number of SUP/EXH blocks m: Weight of DIN rail Note 1) When many valves are operated simultaneously,
A VZ 11 17.5 VT 47.8 (GZ, GS: 48.8) [48.8] G: 300 H: 600 VT 48.6 (GZ, GS: 49.3) [50.3] (Lead wire length) VP Manual override VG (Non-locking) (M5 X 0.8) 41.5 [48] VP (External pilot port) 33.5 28.5 29.1 R P X 22.5 13 5 5 VQ 23 7.5 10 8.6 3-M5 X 0.8 (Piping port) VQZ [ ] for AC VZ L plug connector (L): SYJ3l4-lLll-M5 M plug connector (M): SYJ3l4-lMll-M5 VS 28 28 17 3 2-3.2 17 3 2-3.2 (Mounting
JIS B2401G35 3 pcs. 56 Series AMF Dimensions AMF150C to 350C P Q T S R F E D N Bracket L U (Accessory) O K G M V W J B OUT IN C I A Maintenance space (mm) A Model Port size Bracket related dimensions B C D E F G I 98.5 N 56 J 20 K 5 U 6 V 6 L 12 M 6 W 10 O 35 P 70 Q 26 R 54 S 4.5 T 1.6 AMF150C AMF250C AMF350C 10 54 63 7.5 63 10 1/8, 1/4 83 14 73 76 5 76 10 121 66 24 8 6 6 12 6 10 40 80 28
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% Conditions Base mounted Tubing bore x Length Speed controller Silencer Series CJ2 Series CM2 6 x 1 m AS2301F-06 AN120-M5 AS2001F-06 Series CJ2 Series CM2 4 x 1 m AS1301F-04 AN120-M5 Body ported Tubing bore x Length Speed controller Silencer SYJ3140-M5 SYJ3120-M3 1-5-5 Series SYJ3000 How to Order Light/Surge voltage suppressor Bracket
Add M to the end of the part number for 1 m, L for 3 m, and Z for 5 m. Example) -2M9NL !
NFB MC CNP1 NFB MC L1 L1 Three phase 200 to 230 VAC Single phase 200 to 230 VAC CNP3 CNP3 L2 L2 U U U Motor U Motor L3 L3 V V V V M M N () N W W W W P1 P1 PE PE P2 P2 CNP2 CNP2 P (+) P Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should be connected to L1 and L2 terminals, with nothing connected
12 V Relay, PLC Grommet Yes 24 V 3-wire (NPN) 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 3-wire (PNP) 2-wire 12 V Yes No Yes No 100 V Reed auto switch Relay, PLC IC circuit 100 V or less Grommet 24 V 2-wire 12 V 100 V, 200 V 200 V or less Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid
M5 x 0.8 (A, B port) 10 5 10 2-3.2 (For mounting) 22 2.5 Manual override B A 11 A B 34.4 G: Approx. 300 H: Approx. 600 (Lead wire length) 78.8 [83.2] (Light/surge voltage suppressor) 41.5 [48.5] + 35.6 26.1 R1 P R2 13 5 10 10 10 M5 x 0.8 (P, R1, R2 port) 17.5 14 28 L plug connector (L): SYJ3240-L-M5 M8 connector (W0): SYJ3240-W0-M5 M plug connector (M): SYJ3240-M-M5 Approx. 300 (Lead wire
indication (2-color display) Relay PLC 24 V Yes 12 V 5 V, 12 V 2-wire Water resistant (2-color display) Grommet IC circuit With diagnostic output (2-color display) 4-wire (NPN) Latch type with diagnostic output (2-color display) F7LF Lead wire length symbol 0.5 m ...
19 1.5 4-M5 x 0.8 Prepared hole dia. 4.2 4-M4 x 0.7 depth 4.5 Piping port 2-M5 x 0.8 (Plug: M-5P) 22 0.05 W 8 0.05 33 D B Operating port 2-M5 x 0.8 10 J 5 Mounting reference planes B D 12 9.5 Section AA MXP12-25B Without magnet and switch rail 2-M2 x 0.4 depth 3 For magnet mounting 8 2-M3 x 0.5 depth 3.5 For rail mounting 5.7 3.5 6-M4 x 0.7 depth 4.5 20 20 L (mm) L K MA V J S Z H M W Model
, V = 200 mm/s or less (6) Over 30 stroke, V = 200 mm/s or less 44 (20) 44 (20) 22 (10) 22 (10) 25 20 11 (5) 11 (5) 25 Load mass m lbs (kg) Load mass m lbs (kg) 16 20 12 16 2.2 (1) 2.2 (1) 12 0.22 (0.1) 10 50 100 200 0.22 (0.1) 10 50 100 200 Eccentric distance L (mm) Eccentric distance L (mm) MGPL32 to 100, MGPA32 to 100 (7) 50 stroke or less, V = 200 mm/s or less (8) Over 50 stroke, V =
, PLC Yes Grommet 24 V IC circuit Diagnostic indication (2-color display) 5 V, 12 V 12 V Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.
state switch Relay, PLC 12 V Yes Yes No Grommet 24 V IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 12 V 3-wire (NPN equivalent) A96 A96V 5 V 24 V Grommet A93 A90 A93V A90V Relay, PLC 100 V 2-wire 12 V IC circuit 100 V or less Solid state auto switches marked with are produced upon receipt of order.