Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Stroke: 25mm, Body Option: C (with Rubber Bumper), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel
Magnet: None, Mounting: B (Through-hole, Standard), Bore Size: 50mm, Stroke: 25mm, Body Option: C (with Rubber Bumper), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)
Magnet: D (Built-in), Rod Type: Standard, Mounting: A (Both Ends Tapped), Bore Size: 63mm, Stroke: 25mm, Body Option: C (Rubber Bumper), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: C (with Rubber Bumper), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the
Magnet: D (Built-in), Rod Type: Standard, Mounting: A (Both Ends Tapped), Bore Size: 63mm, Stroke: 25mm, Body Option: C (Rubber Bumper), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 40mm, Stroke: 25mm, Body Option: C (with Rubber Bumper), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Port Thread Type: Rc, Stroke: 25mm, Body Option: C (Rubber Bumper), Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: C (Rubber Bumper), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: L (Shipped Together)
Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: C (Rubber Bumper), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector
Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 12mm, Stroke: 25mm, Body Option: C (Rubber Bumper), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)
Size Order no. 27 16 LE-D-2-7 25 LE-D-19-3 32 LE-D-19-4 Replacement Parts/Grease Pack Applied portion Order no.
2 LE FB16 LEFB16 0 0 500 1000 1500 2000 V (mm/s) -13- 2.3.
LE C A 6 N A (DC24V) (LE ) LESH16RAJ-50BS-R16N1D 6 64 LESH16RAJ-50 I/O N NPN DIN P PNP 1 1.5m D DIN 3 3m 5 5m <> NPNPNP LESH16RAJ-50 NPN NPN 7 - 2.3 1 I/O LEC-CN5-* PLC 1 3 DC24V CN5 CN3 CN4 2 1 () LE-CA-* CN2 120.3 120.3 mm mm 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 3 50 200 50 200 3 3 CN1 DC24V <> AWG20 (0.5mm 2) USB A-miniB type USB LEC-W2
P DC24V (LE ) LEHZ10LK2-4AF-R16N1D 6 64 LEHZ10LK2-4 / I/O N NPN DIN P PNP 1 1.5m D DIN 3 3m 5 5m <> /NPNPNP LEHZ10K2-4 NPN 7 - 2.3 1 I/O LEC-CN5-* 1 PLC 3 / DC24V CN5 CN4 1 CN3 LE-C*-*-* LE-C*-* -*-S 2 CN2 120.3 120.3 mm mm 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN1 3 DC24V USB A-miniB type <> AWG20 (0.5mm 2) USB LEC-W2
C P MJ (LE ) LEFS16B-100B-S1MJS P (DC24V) [LEFS16B-100] MJ CC-Link D DIN S T T <> LEHZ10K2-4 7 - 2.3 *1 CC-Link *4 PLC *3 LEC-CMJDC24V CN5 *1 *2 CN4 LE-CP-LE-CP---S CN3 120.3 120.3 mm mm 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2 *3 DC24V USB A-miniB type CN1 <> ( 2) AWG20 (0.5mm (3m) USB ) LEC-T1-3G LEC-W2 *1 *2 http:/
Tube gasket O-ring O-ring Material Special resin Stainless steel Special resin NBR NBR NBR NBR NBR No. 14 15 22 50 51 52 53 54 Qty. 1 1 2 2 2 2 4 2 14 Series MY2C 16, 25, 40 MY2C G Bore size Stroke Q + Stroke PG (LL) L 4-MM, depth M 4-B depth of counter bore C LA Work piece mounting center line LD through hole PA Work piece mounting center line Cylinder mounting center line PB PC MW LC LE
5 @2 %0 %1 %2 %3 %4 8-13-17 18 Series MY2 16, 25, 40 MY2C G Bore size Stroke Q + Stroke PG (LL) L 4-MM, depth M 4-B depth of counter bore C LA Workpiece mounting center line LD through hole PA Workpiece mounting center line Cylinder mounting center line PB PC MW LC LE Cylinder mounting center line QW PF NX 4 x 2-square nut J PD LB NH NT NW PE PE LW NV Courtesy of Steven Engineering, Inc.-
5 @2 %0 %1 %2 %3 %4 8-13-17 18 Series MY2 16, 25, 40 MY2C G Bore size Stroke Q + Stroke PG (LL) L 4-MM, depth M 4-B depth of counter bore C LA Workpiece mounting center line LD through hole PA Workpiece mounting center line Cylinder mounting center line PB PC MW LC LE Cylinder mounting center line QW PF NX 4 x 2-square nut J PD LB NH NT NW PE PE LW NV Courtesy of Steven Engineering, Inc.-
Applied portion Order no. 21 25 LE-D-2-2 32 LE-D-2-3 Piston rod GR-S-010 (10 g) GR-S-020 (20 g) * Apply grease on the piston rod periodically.
Size Order no. 25 LE-D-6-2 14 32 LE-D-6-3 40 LE-D-6-4 -12- 3. Product Outline 3.1 System construction Refer to the Driver operation manual for system construction. 4.Elictric actuators / Common precautions 4.1 Wiring/Cables Warning 1. Adjustment, installation, inspection, or wiring changes should be conducted after the power supply to this product has been turned off.