Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 240VAC, 50/60Hz, Electrical Entry: Y [DIN Terminal (EN175301-803) w/Connector], Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/2, Thread Type: NPTF, Actuation Type: N.C., Normally Closed, Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3
Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: Y [DIN Terminal (EN175301-803) w/Connector], Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/2, Thread Type: NPTF, Actuation Type: N.C., Normally Closed, Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3
Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Electrical Entry: DIN Terminal w/Connector, Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/8, Thread Type: NPT, Actuation Type: N.C., Normally Closed, Bracket: Bracket, Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3
Pilot, Pressure Specification: High-pressure Type, 1.0MPa, Coil Specification: Standard, Voltage: 24VDC, Electrical Entry: DIN Terminal w/Connector, Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/4, Thread Type: NPT, Actuation Type: N.C., Normally Closed, Bracket: Bracket, Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3
Pressure Specification: High-pressure Type, 1.0MPa, Coil Specification: Standard, Voltage: 24VDC, Electrical Entry: DIN Terminal w/Connector, Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Push-turn Locking Slotted Type, Port Size: 1/4, Thread Type: NPT, Actuation Type: N.C., Normally Closed, Bracket: None, Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3
Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 4 [220VAC (230VAC), 50/60Hz], Electrical Entry: DIN Terminal w/Connector, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 3/8, Thread Type: NPT, Actuation Type: N.C., Normally Closed, Bracket: None, Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3
Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Electrical Entry: DIN Terminal w/Connector, Light & Surge Suppressor: Light & Surge Suppressor, Non-polar, Manual Override: Non-locking Push Type, Port Size: 1/2, Thread Type: Rc, Actuation Type: N.C., Normally Closed, Bracket: None, Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3
Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: DIN Terminal w/Connector, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Push-turn Locking Slotted Type, Port Size: 1/2, Thread Type: NPT, Actuation Type: N.C., Normally Closed, Bracket: Bracket, Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3
Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Electrical Entry: Y [DIN Terminal (EN175301-803) w/Connector], Light & Surge Suppressor: Light & Surge Suppressor, Non-polar, Manual Override: Non-locking Push Type, Port Size: 1/8, Thread Type: NPT, Actuation Type: N.C., Normally Closed, Bracket: Bracket, Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3
m (95% filtered particle size)Max. 0.1 mg/m3 (ANR) (Before saturated with oil: 0.01 mg/m3 (ANR) or less, approx. 0.008 ppm) (2)PolycarbonateStandard250.22
m (95% filtered particle size)Max. 0.1 mg/m3 (ANR) (Before saturated with oil: 0.01 mg/m3 (ANR) or less, approx. 0.008 ppm) (2)PolycarbonateStandard450.44
m (95% filtered particle size)Max. 0.1 mg/m3 (ANR) (Before saturated with oil: 0.01 mg/m3 (ANR) or less, approx. 0.008 ppm) (2)PolycarbonateStandard250.22
m (95% filtered particle size)Max. 0.1 mg/m3 (ANR) (Before saturated with oil: 0.01 mg/m3 (ANR) or less, approx. 0.008 ppm) (2)PolycarbonateOption80.18
m3/sN02NPT1/4118 g90 gC01Rc1/8114 g86 g1 x 10?5 Pa?m3/s
m (95% filtered particle size)Max. 0.1 mg/m3 (ANR) (Before saturated with oil: 0.01 mg/m3 (ANR) or less, approx. 0.008 ppm) (2)PolycarbonateOption80.18
m (95% filtered particle size)Max. 0.1 mg/m3 (ANR) (Before saturated with oil: 0.01 mg/m3 (ANR) or less, approx. 0.008 ppm) (2)PolycarbonateStandard250.22
m (95% filtered particle size)Max. 0.1 mg/m3 (ANR) (Before saturated with oil: 0.01 mg/m3 (ANR) or less, approx. 0.008 ppm) (2)PolycarbonateStandard250.22
m3/sN02NPT1/4118 g90 gC01Rc1/8114 g86 g1 x 10?5 Pa?m3/s
m (95% filtered particle size)Max. 0.1 mg/m3 (ANR) (Before saturated with oil: 0.01 mg/m3 (ANR) or less, approx. 0.008 ppm) (2)PolycarbonateStandard250.22
m (95% filtered particle size)Max. 0.1 mg/m3 (ANR) (Before saturated with oil: 0.01 mg/m3 (ANR) or less, approx. 0.008 ppm) (2)PolycarbonateStandard250.22