SMC Corporation of America
Elite Part Number Search
Search Results "LEY25DEA-50C-R1C918"

5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)10.5 MPa?5 to 50C Note 1)20 times/minVertical upwards1/2?9.5751/83.180

5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)10.5 MPa?5 to 50C Note 1)20 times/minVertical upwards3/8?8541/8260

5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)5.5 MPa?5 to 50C Note 1)20 times/minVertical upwards1/2?8.7 ?861/83.180

5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)10.5 MPa?5 to 50C Note 1)20 times/minVertical upwards3/4?131401/45.6100

5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)10.5 MPa?5 to 50C Note 1)20 times/minVertical upwards1/2?9.5751/83.180

5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)5.5 MPa?5 to 50C Note 1)20 times/minVertical upwards1/2?8.7 ?861/83.180

1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?

5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)10.5 MPa?5 to 50C Note 1)20 times/minVertical upwards3/8?3.9 ?151/8260

5 to 50C Note 1)Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)10.5 MPa?5 to 50C Note 1)20 times/minVertical upwards1/2?5.2 ?291/83.180

0.12% (Full span)/C0 to 50C (No condensation)Equivalent to IP65 ?Built-in One-touch fittingsFor single unitFor single unitManifoldManifold100 g or less (without option)

pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC , Response time (0.5MPa) w/o indicator light and surge voltage suppressor: 32ms or less , Ambient and fluid temperature: 50C

See individual series information for replacements. 5 port solenoid valve, metric - old style see replacement series SYJ7000 - New Style , Operating pressure range: 0.1 to 0.7MPa , Response time (0.5MPa): 20 (2 position), 50 (3 position) , Ambient and fluid temperature: Max. 50C , Lubrication: non-lube, VZ5000, VALVE, VZ5000 SOL VALVE 4/5 PORT, 2D, VZ5000, 0.62463 lb

See individual series information for replacements. 5 port solenoid valve, metric - old style see replacement series SYJ7000 - New Style , Operating pressure range: 0.1 to 0.7MPa , Response time (0.5MPa): 20 (2 position), 50 (3 position) , Ambient and fluid temperature: Max. 50C , Lubrication: non-lube, VZ5000, VALVE, VZ5000 SOL VALVE 4/5 PORT, 2D, VZ5000, 0.25325 lb

See individual series information for replacements. 5 port solenoid valve, metric - old style see replacement series SYJ7000 - New Style , Operating pressure range: 0.1 to 0.7MPa , Response time (0.5MPa): 20 (2 position), 50 (3 position) , Ambient and fluid temperature: Max. 50C , Lubrication: non-lube, VZ5000, VALVE, VZ5000 SOL VALVE 4/5 PORT, 2E, VZ5000, 0.528 lb

Manifold options include control unit, serial interface unit and a coaxial fitting.Fluid: air, Operating pressure range: 0.1MPa 1.0MPa, Effective area mm 2 (Cv): 5.4 13.2 (0.3 0.73), Coil rated voltage: 6, 12, 48VDC; 24, 48, 110, 220VAC, Protection structure: dust proof (protection class 0 based on JIS C0920), Ambient and fluid temperature: -10 to 50C, VZS3000, VALVE, VZS3000 SOL VALVE

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient and fluid temperature: max. 50C SY100 SOLENOID VALVE.

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient and fluid temperature: max. 50C, VALVE, SOL, BODY PT,

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient and fluid temperature: max. 50C, VALVE, SOL, BODY PT,

35 (3 position) , Ambient and fluid temperature: Max. 50C , Lubrication: non-lube, VZ3000, VALVE, VZ3000 SOL VALVE 4/5 PORT, 2E, VZ3000

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient and fluid temperature: max. 50C, DIN CONNECTOR, VALVE