Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Rubber cushion, Operating Pressure(
Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: NPT, Stroke: 400mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of
Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: NPT, Stroke: 400mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Pre-wired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 2
The CNA2 series cylinder with lock is suitable for mid-stroke stops, emergency stops, and drop prevention. An equal holding force in extending and retracting directions make it possible to lock at either end of the stroke. High reliability and stable holding force are maintained by using a substantially lengthened brake shoe with superior wear resistance. The locking mechanism is isolated
The CNA2 series cylinder with lock is suitable for mid-stroke stops, emergency stops, and drop prevention. An equal holding force in extending and retracting directions make it possible to lock at either end of the stroke. High reliability and stable holding force are maintained by using a substantially lengthened brake shoe with superior wear resistance. The locking mechanism is isolated
The CNA2 series cylinder with lock is suitable for mid-stroke stops, emergency stops, and drop prevention. An equal holding force in extending and retracting directions make it possible to lock at either end of the stroke. High reliability and stable holding force are maintained by using a substantially lengthened brake shoe with superior wear resistance. The locking mechanism is isolated
The CNA2 series cylinder with lock is suitable for mid-stroke stops, emergency stops, and drop prevention. An equal holding force in extending and retracting directions make it possible to lock at either end of the stroke. High reliability and stable holding force are maintained by using a substantially lengthened brake shoe with superior wear resistance. The locking mechanism is isolated
(Inlet pressure is 0.7 MPa, at pressure drop of 0.02 MPa) Series Filtration Temperature C Pressure MPa Page Replacement of element Disc type SFA10 26 SFA20 70 P . 299 HAA HAW AT 0.01 m SFA30 140 Filtering efficiency 99.99% ( ) IDF IDU Membrane element ( ) IDF FS Cartridge type Disposable type IDFA SFB10 45 0.99 5 to 80 Replaceable P . 302 Straight type IDFB IDH ID IDG Nominal IDK 120 m 400
Count Pressure characteristics Flow characteristics Supply pressure: 0.2MPa Set pressure: 0.05MPa Relief flow characteristics Supply pressure: 0.2MPa 0.15 1.0 0.25 Output deviation factor (%F.S.) 0.20 0.5 Set pressure (MPa) Set pressure (MPa) 0.10 Set point 0.15 0.0 0.10 0.05 0.5 0.05 1.0 0 200 400 600 0.00 0.0 0.1 0.2 0.3 0 200 400 800 600 Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
Thomas Liquid Diaphragm Pump Flow Rate: 400 ml / min , 400 ml / min, Max Pressure: 15 m H20 , 15 m H20, Max Suction: 6 m H20 , 6 m H20, Voltage (DC): 24, DC Motor Type: Standard, Net Weight: .41 lbs. / .19 Kg Series Configured Datasheet.
Thomas Liquid Diaphragm Pump Flow Rate: 400 ml / min , 400 ml / min, Max Pressure: 15 m H20 , 15 m H20, Max Suction: 6 m H20 , 6 m H20, Voltage (DC): 24, DC Motor Type: Standard, Net Weight: .41 lbs. / .19 Kg Series Configured Datasheet.
Thomas Liquid Diaphragm Pump Flow Rate: 400 ml / min , 400 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 24, DC Motor Type: Standard, Net Weight: .41 lbs. / .19 Kg Series Configured Datasheet.
Thomas Liquid Diaphragm Pump Flow Rate: 400 ml / min , 400 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 12, DC Motor Type: Standard, Net Weight: .41 lbs. / .19 Kg Series Configured Datasheet.
Thomas Liquid Diaphragm Pump Flow Rate: 400 ml / min , 400 ml / min, Max Pressure: 15 m H20 , 15 m H20, Max Suction: 6 m H20 , 6 m H20, Voltage (DC): 12, DC Motor Type: Standard, Net Weight: .41 lbs. / .19 Kg Series Configured Datasheet.