SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2B50-100-D-M9PSDPC"

-14No.EX-OMP0004CN-I D 3 -15No.EX-OMP0004CN-I LED LED LED L ERR L RUN PWR ON OFF PWR(V) ON OFF -16No.EX-OMP0004CN-I DIP (0.2 Nm) -17No.EX-OMP0004CN-I 5 L ERRLED 00 65 L ERRLED HOLD/CLEAR HOLD/CLEAR No.1 HOLD ON CLEAR OFF No.2 ON 110 OFF -18No.EX-OMP0004CN-I EX260-SMJI/O (1 32 /32 ) SI [01] QJ61BT11N EX260-SMJ1/2 I/O (1 ) (RY) (RX) (RX) (RY) E0H RX0FRX00

LC1-1-S1 (PC-98 (MS-DOS) edition LC1-1-W1 (Windows 95 edition) and LC1-1-R (dedicated communication cable) Power supply 1 2 Note 2) 100/110VAC 50/60Hz 200/220VAC 50/60Hz or LC1-1-T1(Teaching box) are required. For ordering information, refer to the option part numbers on page 62.

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: C (Rubber Bumper), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint), Auto Switch: M9BWV--Solid State, 2-color Indication, 2 Wire, Vertical, Lead Wire

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint), Auto Switch: M9PV--Solid State , Gen

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 50mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 50mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 45mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 80mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 35mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: C (Rubber Bumper), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

K M H 2-4.5 mounting hole D N-FA Applicable tubing O.D. MS T VMG Applicable tubing O.D.

AUTO-SWITCH, ACTUATOR, AUTO-SWITCH ACCESSORY, 22, AUTO-SWITCH (ACCESSORY), 0.03527 lb

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25

Resistance to ground should be 100 ohms or less. Troubleshooting 1 2 Cable color: Signal name Pin No.

D Shows how precisely the pressure can be indicated or set by the digital Pressure switch. When 1 digit = 1 kPa, the pressure is given with an increment Digit (Min. setting unit) of 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.

Ratio of discharge amount to fresh water (%) 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity (mPa s) mPas Silicone oil Lubricant Vegetable oil Water 60 to 80 1 6080 340 950 1500 3150 9800 Viscosity (mPa s) cp 0 100 1000 10 150 | 2650 45 | 2 3000 4500 Tomato juice Honey Medical barium Wooster source Cutting oil 4500 45 2000 to 3000 8 - 8.

VXF*-OMK0002-D PRODUCT NAME Valve Controller MODEL / Series / Product Number VXFC06A VXFC10A Contents 1. Safety Instructions P2-5 2. Specifications P6 3. Name of Parts P7-8 4. Wiring P9 5. Description of operation P10-11 6. Cascade connection P12-13 7.

(Specified accuracy is not satisfied.) equipment (such as the A/D) is proper. After energizing, indication and output can drift. For detecting fine pressure, warm up the product for 20 to 30 minutes. Check if the product satisfies the specified accuracy in 20 minutes after supplying power. Insufficient warm-up Product failure Replace the product. Rework the piping.