SMC Corporation of America
Elite Part Number Search
Search Results "ARJ1020F-M5-06-1"

Please contact us for the latest version.sales@ocaire.com, VVX* BASE MT 1/8, VALVE, VVX* MANIFOLD VX SERIES, NJ, VVX* BASE MT 1/8

Please contact us for the latest version.sales@ocaire.com, VVX* BASE MT 1/4, VALVE, VVX* MANIFOLD VX SERIES, PJ, VVX* BASE MT 1/4

This is a legacy product, and replaced byAR10-M5-1-A, REGULATOR, MODULAR, AIRLINE EQUIPMENT, AR MASS PRO, AA, AR MASS PRO M5 MODULAR (PT), 1.63142 lb

Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only), Calibration Certificate: A (Made to Order)

Body Class: 2 (Orifice Dia. ø4), Valve Type: 0 (N.C.), Applicable Tubing Size: 06 (ø6mm), Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: Standard, Option: 1 (With Flow Rate Adjustment)

Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: N (NPT)

Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)

Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Option: BG (B + G), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

N Port P1 0 3 ITV Thread type Fittings for M5 IC Nil F N T Rc G Note 1) Body size Port size Body size Port Port size 1(P), 2(A) 3(R) ITVH NPT NPTF 8 1 01 02 02 03 04 04 06 10 10 12 14 20 Nil 01 02 ITVX 1 4 1 ForVEX13 (NBR seals) Fixed orifice assembly (with O-ring) part no.: VEX1-A30-3 ForVEX133B(FKMseals) Fixed orifice assembly (with O-ring) part no.: VEX1-A30-3B Note)

x 0.8 A5 M5 x 0.8 Nil Use the connection thread. 02 2 04 4 06 6 Female thread B5 M5 x 0.8 One-touch fitting One-touch fitting 02 2 04 4 Barb fitting U2 For 2 polyurethane tubing1 U4 For 4 soft tubing2 A10 M10 x 1 U2 For 2 polyurethane tubing1 U4 For 4 soft tubing2 U6 For 6 soft tubing2 Barb fitting Male thread Female thread B5 M5 x 0.8 02 2 1 Polyurethane tube

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4)

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 23 (ø3.2)

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 3 (Universal), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4)

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 3 (Universal), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 23 (ø3.2)

Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 06 (ø6), Sealant: S (with Sealant), Push lock: A (Push-lock)

Please contact us for the latest version.sales@ocaire.com, VALVE, MECHL 1/4 RLR, VALVE, VM BODY PT 1/4, .50600 lb

Please contact us for the latest version.sales@ocaire.com, REGULATOR, MODULAR, AIRLINE EQUIPMENT, AR MASS PRO, GA, AR MASS PRO 3/4 MODULAR (PT), 2.68963 lb, ModelPort sizePressure gauge port size Note 1)FluidAmbient and fluid temperature Note 3)Proof pressureMaximum operating pressureSet pressure rangeRelief pressure Note 4)ConstructionMass (kg)AR50(K)3/4, 11/4Air?

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED CONTROLLER, FLOW CONTROL, SVD, 6 lb

(kg)Pressure typeVEP31413 8 , 1 2 , 3 4Air (Inert gas)1.5 MPa1.0 MPa0 to 50C (With no condensation)0.05 s or less3% F.S.3% F.S.0.5% F.S.3% F.S. or lessNot required (Use turbine oil Class 1, ISO VG32, if lubricated.)1.4

Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes.  Options include a mounting bracket and set nuts for panel mounting, and a pressure gauge.  The modular design of the AR series connects with other SMC air preparation equipment., REGULATOR, AIRLINE