Theoretical Cylinder Thrust Symbol Specifications 1200 -XB11 -XB13 -X116 -X132 -X160 -X168 -X206 -X210 -X322 -X324 -XC57 Long stroke (2001mm and up) Low speed specifications (7 to 50mm/s) 1100 Hydro specifications 40 40 Axial ports 1000 High speed specifications Helical insert thread specifications 900 Added mounting tap positions for slider Oil-free exterior specifications Theoretical thrust
Magnetic Holding Power (lbs. force Series NCY2B Cylinder Theoretical Output 06, 410 100 o'15, 025,032, Q40 ^1100 3rooo I s00 I eoo g 7oo i m o 90 80 70 60 50 40 z 3 E .9 !
Magnetic Holding Power (lbs. force Series NCY2B Cylinder Theoretical Output 06, 410 100 o'15, 025,032, Q40 ^1100 3rooo I s00 I eoo g 7oo i m o 90 80 70 60 50 40 z 3 E .9 !
C 100 95 8(4)-6.2 (160) () () 110 95 20 95 B (140) () () Dimensions A Stroke Model B C D Note) LG1H202100-F LG1H202200-F LG1H202300-F LG1H202400-F LG1H202500-F LG1H202600-F LG1H202700-F LG1H202800-F LG1H202900-F LG1H202-1000-F LG1H202-1200-F 100 200 300 400 500 600 700 800 900 1000 1200 245.7 345.7 445.7 545.7 645.7 745.7 845.7 945.7 1045.7 1145.7 1345.7 400 500 600 700 800 900 1000 1100
Applicable strokes: 250, 350, 450, 550, 650, 700, 750, 850, 900, 950, 1050, 1100, 1150, 1250, 1300, 1350, 1400, 1450 Example) LJ1H3031PD-250-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Pitching Rolling Yawing Mounting orientation Load movement direction 117 137 123 Model LJ1H30 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep a = 1000 2000 L1
50 to 2000 50 to 2000 20 150 to 250 150 to 1300 100 to 2000 50 to 2000 50 to 125 50 to 1100 50 to 2000 50 to 2000 30 50 to 200 50 to 1300 50 to 2000 50 to 2000 50 to 125 50 to 1100 50 to 2000 50 to 2000 Energy saving static neutralization cartridge High speed static neutralization cartridge Energy saving static neutralization cartridge Energy saving high-efficiency cartridge Energy saving
Bore size (mm) Standard stroke (mm) Range of manufacturable stroke* Without rod boot With rod boot Without rod boot With rod boot 40 25 to 850 25 to 700 Up to 1200 Up to 950 50 25 to 800 25 to 650 Up to 1150 Up to 900 63 25 to 800 25 to 650 Up to 1150 Up to 900 80 25 to 750 25 to 600 Up to 1100 Up to 900 100 25 to 750 25 to 600 Up to 1100 Up to 850 Refer to pages 692 to 697 for cylinders
1100 200 450 450 AC**C-A 150 330 800 800 L/min(ANR)AC**D-A Class 1 turbine oil (ISO VG32) Recommended lubricant Bowl material Polycarbonate Semi-standard Bowl guard Steel plate Standard Polycarbonate Relieving type Construction / Regulator Note1 Conditions: Mist separator inlet pressure: 0.7MPa(AC**C-A), 0.5MPa(AC**D-A).
Applicable strokes: 250, 350, 450, 550, 650, 700, 750, 850, 900, 950, 1050, 1100, 1150, 1250, 1300, 1350, 1400, 1450 Example) LJ1S3031SC-250-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Mounting orientation Load movement direction Model 26.6 40.2 25.8 Pitching Rolling Yawing LJ1S30 300 a = 500 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a = 1000
Specification 2.1 Slider type LEF Series / Ball screw drive Specification (1) Step motor (servo 24VDC) Ball screw drive LEFS16 LEFS25 LEFS32 Model 50 to 500 50 to 800 50 to 1000 Stroke [mm] Note1) 14 15 12 25 30 20 45 50 LECP6/LECP1/LECPMJ/JXC91 Work load [kg] Note2) Horizontal 9 10 10 20 20 15 40 45 LECPA 2 4 0.5 7.5 15 4 10 20 Vertical 500 10 to 700 5 to 360 20 to 1100 12 to 750 6 to 400
1100 1100 1750 110 130 110 180 140 220 4700 4300 3450 2400 1950 1750 1750 1750 2750 2 Air Slide Table/Reversible Type Series MXQR Optional Specifications Adjusters Three different types of adjusting bolt have been standardized for extension stroke end, retraction stroke end and both ends adjuster and cushion mechanisms.
Caution Theoretical Cylinder Thrust 6, 10 15, 20, 25, 32, 40 50, 63 CY3B CY3R CY3B CY3R CY1S 63 63 1200 40 40 1100 3000 100 90 80 70 60 50 40 30 20 10 Theoretical thrust (holding force) (N) Theoretical thrust (holding force) (N) Theoretical thrust (holding force) (N) H CY1L Bore size 10 Bore size 2500 1000 900 800 700 10 50 50 H 32 32 2000 CY1H 1500 600 25 25 500 400 300 200 100 CY1F 1000
Allowable kinetic energy (mJ) Size With internal shock absorber With adjustment bolt With internal shock absorber With external shock absorber With external shock absorber With adjustment bolt For high energy For low energy 1 2 3 7 10 20 30 50 70 100 200 1 0.2 to 0.7 1.5 2 6 39 7 161 231 116 25 0.2 to 1.0 Note) 574 1060 0.2 to 0.7 0.2 to 1.0 116 48 805 1210 294 81 1310 1820 0.2 to 1.5 1100
900 4-2 Controller 100 25750 25600 1100 850 CEU2 Output Method None NPN Open Collector P PNP Open Collector 16 4-3 Extension Cable CE1-R Length of Cable Postscript None Extension Cable 05 5m C Extension Cable + Connector 10 10m 15 15m 20 20m Connectors Connection Symbol Core Wire Color A White B Yellow C , D Brown, Blue E Red F Black G (Shield) 17 5.
[Number of emitter cartridges/Bar weight] Bar length (mm) 300 380 620 780 1100 1260 1500 1900 2300 Number of emitter cartridges 3 4 7 9 13 15 18 23 28 Weight (g) 330 400 600 720 1000 1100 1500 2000 2500 29 Doc.No.IZ-OMK0015D 4-2.
pressure dew point 50F (10C) 177 (300) 251 (426) 353 (600) 459 (780) Inlet air pressure [psi (MPa)] 100 (0.7) Inlet air temperature [F (C)] 100 (37.8) Ambient temperature [F (C)] 100 (37.8) Single-phase 115 VAC (60 Hz) Single-phase 230 VAC (60 Hz) Power supply voltage (Frequency)4 Maximum air flow capacity Air flow capacity calculated with the correction factors Power consumption5 [W] 1100
Wire the vacuum switch separately. 1100
fluid Dry air, N2 3-color/ 2-screen display Accumulated value 2-row display of main screen and sub screen Peak/Bottom value Instantaneous flow rate (Main screen) Set value (Sub screen) Line name Expanded flow range Compact, Space saving Wide range of flow measurement with one product Compared with the current PF2A, Flow ratio 78 % reduction Weight 74% reduction 100:1 Mounting space 1100
completed FET(Open Drain), DC28V, 100mA or less Effective elimination distance 50 to 2000mm (Sensing DC mode 200 to 2000mm) Ambient temperature 0 to + 50oC Ambient humidity 35 to 80% Rh (No dew condensation) Material Ionizer cover: ABS, Electrode: Tungsten Vibration resistance Endurance 50Hz Amplitude 1mm 2 hours to X,Y,Z each direction of vibration Impact resistance 10G Weight (g) 330 710 1100
SPECIFICATIONS Model AFM20-A AFM30-A AFM40-A AFM40-06-A Port size 1/81/4 1/43/8 1/43/81/2 3/4 Fluid Air Ambient and fluid -5 60 (Should be no freezing) temperature Proof pressure Max. operating pressure 1.5 MPa 1.0 MPa Min. operating pressure 0.05 MPa 0.3 m (FILTRATION EFECIENCY 99.9%) Filtration MAX.1.0 mg/m3(ANR)(0.008ppm) Note1 Note2 Oil mist density at the out side 1100 Flow rateLminANR